PROGRAMMING THE BREWER (cont.)

BREW COUNTERS

This function allows the operator to track the number of brew cycles completed. The number of brew cycles on the left side, the right side, and the total of both combined can be tracked on DUAL brewers. There is one resettable counter, and one life counter that is not resettable for SINGLE brewers and three resettable counters, and one life counter that is not resettable for DUAL brewers.

Procedures to view/reset the brew counters:

1.Press and hold the upper right hidden switch until the display reads UNITS. Release the switch. Con- tinue to press and release switch until the display reads BREW COUNTERS.

2.Pressing NO in this screen will advance to the next function. Press YES to view the first brew counter (left side on DUAL brewers). This number repre- sents the brew cycles initiated since that counter was last reset.

3.To advance to the other counters, press and release NEXT. The four counters for DUAL brewers are as follows:

LEFT - total brews on left side (resettable) RIGHT - total brews on right side (resettable) LEFT AND RIGHT - total brews on left and right sides combined (resettable)

LEFT AND RIGHT - total brews on left and right sides combined (non-resettable)

4.To reset any of the counters to zero (except for the non-resettable counter), press and release RESET when viewing that particular counter's screen.

5.When finished, press NEXT to advance counter screens until the display reads BREW COUNTERS. Press and release NO to advance to the next function screen, or press and release the ON/OFF switch (either on DUAL brewers) on the front switch panel to exit the BREW COUNTERS function and return to the MAIN SCREEN.

BREW COUNTERS?

NO YES

EXIT TO

NEXT FUNCTION

SCREEN

SINGLE

BREWERS

X XXX

NEXT RESET

DUAL

BREWERS

LEFT

X XXX

 

NEXT RESET

RESETS LEFT

COUNTER

X XXX

RIGHT

X XXX

NEXT

 

NEXT RESET

RESETS RIGHT

COUNTER

L+R

X XXX

 

NEXT RESET

RESETS BOTH

LEFT AND RIGHT

COUNTERs

L+R

X XXX

NEXT

Page 33

41341 080108

 

Image 33
Contents Dual SH DBC BUNN-O-MATIC Commercial Product Warranty Introduction Glossary Programming Programming SwitchesScreen Programming Lockout Switch mounted on main control boardOutputs Main ScreenNot using a Smart Funnel and/or a G9-2T DBC or MHG Grinder Using a Smart Funnel and a G9-2T DBC or MHG GrinderRecipe Programing Methods RecipesContinue to LevelProgram Flow Diagram Program Flow Diagram Procedure for modifying units of measure Units Setting Units of MeasureNEW Recipe ? Enable EnergysavrSET NEW Recipe Procedure for Setting the RecipeSizes DONE? SET NEW RecipeSET NEW Recipes Procedure to program the coffee nameReview RECIPES? No YES Procedure for reviewing recipes Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee FavorsReview Recipes WAS the Last RecipeBatches DONE? No YES Brew OZ Setting or Adjusting Brew VOL- UmesBypass Modifying pulse brew SET Pulse BrewSET Pulse Brew SET Pulse Brew Easy Pulse Setup SET Pulse Brew Enter Times TIMES?DONE? Batches DONE? SET PreinfusionProcedure to modify drip times Setup CompleteDrip Time now displayed on non funnel lock units as well Reads Copy Settings Procedure to copy settingsAssign Recipes OnlyYOU SURE? Enable ADS?Are YOU SURE? SET TempSET Temp Procedure to set ready temperatureSET Ready Refill Range 20 toProcedure to adjust the flow rate setting Spray OZ/M Single BrewersSpray OZ/M Dual Brewers Bypass OZ/M Dual Brewers Bypass OZ/M Single BrewersProcedures to calibrate the sprayhead flow rate Calibrate FlowCalibrate Flow ? Brate Bypass .. Press Brew to Start Procedures to calibrate the bypass flow rateBrew Counters Procedures to view/reset the brew countersServer Detect Funnel DetectServer not in Place Service Tools Programming the Brewer SERVERS? Nothing PressedFactory Defaults Procedure to set factory defaultsTest FREQUENCY?