Bunn SNG0033000 manual Service Tools

Page 35

PROGRAMMING THE BREWER (cont.)

SERVICE TOOLS

This function allows the testing of individual com- ponents and the ability to check switches for proper function. This function also tests the Soft Heat server's status on the brewer (in place or removed), and the funnel sensor coil's frequency (diagnostic tool for troubleshooting purposes only).

Testing individual components (outputs):

This will allow the operator to test the operation of individual components and outputs of the brewer. The components that can be individually tested are as follows:

SINGLE Brewers

Brew Valve

Bypass Valve

Funnel Lock (Optional)

Server

Refill Valve

Tank Heaters

Heater Contactor

DUAL Brewers

Left Brew Valve

Left Bypass

Left Funnel Lock

Left Server

Right Brew Valve

Right Bypass

Right Funel Lock

Right Server

Refill Valve

Tank Heaters

Heater Contactor

Procedure to test components (outputs):

1.Place brew funnel(s) into rails on the brewer (both sides on DUAL brewers).

2.Place a Soft Heat server(s) beneath the brew funnel(s).

3.Press and hold the upper right hidden switch until display reads UNITS. Release the switch. Continue to press and release switch until SERVICE TOOLS appears.

4.Press YES to run tests on various components and outputs within the brewer. Pressing NO will exit this function and advance to next function screen.

5.The display should read TEST OUTPUTS.

6.Press and release YES. The display should read: BREW VALVE on SINGLE brewers

LEFT BREW VALVE on DUAL brewers.

7.To test BREW VALVE, press ON. If the brew valve is functional, water should run from the brewer (left side on DUAL brewers)

8.Press OFF to end flow of water.

9.Press NEXT to advance to the next component to be tested.

NOTE: To bypass testing any component, press NEXT to advance to the next one, without testing the previ- ous component.

10.To test BREW BYPASS on SINGLE brewers or LEFT BREW BYPASS on DUAL brewers, press ON. If the bypass valve is functional, water should run from the brew bypass (left side on DUAL brewers).

11.Press OFF to end flow of water.

12.Press NEXT to advance to the next component to be tested.

13.To test FUNNEL LOCK on SINGLE brewers or LEFT FUNNEL LOCK on DUAL brewers, press ON. If the funnel lock is functional, the lock will come down to hold the funnel in place.

14.Press OFF to retract the funnel lock.

15.Press NEXT to advance to the next component to be tested.

16.To test SERVER on SINGLE brewers or LEFT SERVER on DUAL brewers, press ON. If the server and the sensor are functional, the light on the lower right corner of the server will illuminate.

17.Press OFF to end testing of server.

18.Press NEXT to advance to the next component to be tested.

19.For DUAL brewers, follow steps 7 through 15 to test the right side components.

20.To test REFILL VALVE, press ON. If the refill valve is functional, the sound of the valve operating will be heard.

21.Press OFF to end testing of refill valve.

22.Press NEXT to advance to the next component to be tested.

23.To test TANK HEATERS, connect a voltmeter across each of the tank heaters to check for voltage.

24.Press ON. The correct voltage should be present at the heater terminals.

25.Press OFF to end testing of the tank heaters.

Page 35

41341 080108

 

Image 35
Contents Dual SH DBC BUNN-O-MATIC Commercial Product Warranty Introduction Glossary Programming Programming SwitchesMain Screen Programming Lockout Switch mounted on main control boardScreen OutputsRecipes Using a Smart Funnel and a G9-2T DBC or MHG GrinderNot using a Smart Funnel and/or a G9-2T DBC or MHG Grinder Recipe Programing MethodsContinue to LevelProgram Flow Diagram Program Flow Diagram Procedure for modifying units of measure Units Setting Units of MeasureNEW Recipe ? Enable EnergysavrSET NEW Recipe Procedure for Setting the RecipeSizes DONE? SET NEW RecipeSET NEW Recipes Procedure to program the coffee nameReview RECIPES? No YES WAS the Last Recipe Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee FavorsProcedure for reviewing recipes Review RecipesBatches DONE? No YES Brew OZ Setting or Adjusting Brew VOL- UmesBypass Modifying pulse brew SET Pulse BrewSET Pulse Brew SET Pulse Brew Easy Pulse Setup DONE? SET Pulse Brew Enter TimesTIMES? Batches DONE? SET PreinfusionDrip Time now displayed on non funnel lock units as well Procedure to modify drip timesSetup Complete Only Procedure to copy settingsReads Copy Settings Assign RecipesSET Temp Enable ADS?YOU SURE? Are YOU SURE?Refill Range 20 to Procedure to set ready temperatureSET Temp SET ReadySpray OZ/M Dual Brewers Procedure to adjust the flow rate settingSpray OZ/M Single Brewers Bypass OZ/M Dual Brewers Bypass OZ/M Single BrewersCalibrate Flow ? Procedures to calibrate the sprayhead flow rateCalibrate Flow Brate Bypass .. Press Brew to Start Procedures to calibrate the bypass flow rateBrew Counters Procedures to view/reset the brew countersServer not in Place Server DetectFunnel Detect Service Tools Programming the Brewer SERVERS? Nothing PressedTest FREQUENCY? Factory DefaultsProcedure to set factory defaults