Bunn SNG0033000 manual SET Temp, Procedure to set ready temperature, SET Ready, Refill Range 20 to

Page 28

PROGRAMMING THE BREWER (cont.)

SET TEMP (cont.)

2.To adjust the brew temperature, press (-)to de- crease or (+) to increase the brew temperature.

3.When finished, press and release DONE to save the new setting, exit the SET TEMP function and advance to the next function screen, SET READY. Another alternative is to press and release the ON/ OFF switch (either on DUAL brewers) located on the front switch panel to exit the SET TEMP func- tion and return to the MAIN SCREEN.

SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C) This function allows the operator to set the mini- mum temperature allowable to start a brew cycle. The range can be from 185˚F (85˚C) to within 2˚F (-1.7°C) of the SET TEMP. The water must be at the SET READY temperature or higher for the display to indicate READY TO BREW. If brew lockout is enabled, the brewing pro-

cess will not start below this READY temperature.

NOTE: The upper limit for SET READY temperature is 2˚F (-1.7°C) less than the water temperature (SET TEMP) setting.

SET READY: XXX° (-) DONE (+)

Procedure to set ready temperature:

1.Press and hold upper right hidden switch until the display reads UNITS. Release switch. Continue to press and release switch until the display reads

SET READY.

2.To adjust the ready temperature, press the (-)button to decrease, or (+) to increase the ready temperature.

3.When finished, press and release DONE to save the new setting, exit the SET READY function and advance to the next function screen, REFILL. Another alternative is to press and release the ON/OFF switch (either on DUAL brewers) located on the front switch panel to exit the SET READY function and return to the MAIN SCREEN.

REFILL - Range: 20 to 230

This function allows the operator to adjust the sensitivity of the refill circuit. This is mainly a trouble- shooting feature. Water in different geographical loca- tions can have different conductivities. By adjusting the sensitivity of the refill circuit, this will allow the brewer to operate under various water conditions.

XXXREFILL -> XXX (-) DONE (+)

Procedure to set the sensitivity threshold of the refill circuit:

NOTE: Make sure the water in the tank is touching the refill probe.

1.Press and hold upper right hidden switch until the display reads UNITS. Release switch. Continue to press and release switch until the display reads REFILL and shows a number on both sides of the word.

2.To adjust the threshold setting, press (-)to de- crease, or (+) to increase the setting.

NOTE: Always make sure that the number on the right is larger than the number on the left when water is in contact with the refill probe in the tank.

3.When finished, press and release DONE. This saves the new setting and advances to the next function screen:

SPRY OZ/M (SINGLE brewers)

L SPRY OZ/M (DUAL brewers). Another alternative is to press and release the ON/OFF switch (either on DUAL brewers) located on the front switch panel to exit REFILL and return to the MAIN SCREEN.

Page 28

41341 080108

 

Image 28
Contents Dual SH DBC BUNN-O-MATIC Commercial Product Warranty Introduction Glossary Programming Switches ProgrammingProgramming Lockout Switch mounted on main control board ScreenOutputs Main ScreenUsing a Smart Funnel and a G9-2T DBC or MHG Grinder Not using a Smart Funnel and/or a G9-2T DBC or MHG GrinderRecipe Programing Methods RecipesLevel Continue toProgram Flow Diagram Program Flow Diagram Units Setting Units of Measure Procedure for modifying units of measureEnable Energysavr NEW Recipe ?Procedure for Setting the Recipe SET NEW RecipeSET NEW Recipe Sizes DONE?Procedure to program the coffee name SET NEW RecipesReview RECIPES? No YES Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee Favors Procedure for reviewing recipesReview Recipes WAS the Last RecipeBrew OZ Setting or Adjusting Brew VOL- Umes Batches DONE? No YESBypass SET Pulse Brew Modifying pulse brewSET Pulse Brew SET Pulse Brew Easy Pulse Setup TIMES? SET Pulse Brew Enter TimesDONE? SET Preinfusion Batches DONE?Setup Complete Procedure to modify drip timesDrip Time now displayed on non funnel lock units as well Procedure to copy settings Reads Copy SettingsAssign Recipes OnlyEnable ADS? YOU SURE?Are YOU SURE? SET TempProcedure to set ready temperature SET TempSET Ready Refill Range 20 toSpray OZ/M Single Brewers Procedure to adjust the flow rate settingSpray OZ/M Dual Brewers Bypass OZ/M Single Brewers Bypass OZ/M Dual BrewersCalibrate Flow Procedures to calibrate the sprayhead flow rateCalibrate Flow ? Procedures to calibrate the bypass flow rate Brate Bypass .. Press Brew to StartProcedures to view/reset the brew counters Brew CountersFunnel Detect Server DetectServer not in Place Service Tools Programming the Brewer Nothing Pressed SERVERS?Procedure to set factory defaults Factory DefaultsTest FREQUENCY?