PROGRAMMING THE BREWER (cont.)

SERVICE TOOLS (cont.)

3.Press and hold the upper right hidden switch until the display reads UNITS. Release the switch. Continue pressing and releasing the upper right hidden switch until SERVICE TOOLS appears.

4.Pressing NO will exit this function and advance to the next function screen. Press YES to run tests on various components and outputs within the brewer.

5.The display should read TEST OUTPUTS?.

6.In TEST OUTPUTS screen, press NO. Continue to press and release NO until the display reads

TEST FREQUENCY?.

7.Press and release YES. The display will show the frequency of the sensor coil circuits. This is for diagnostic service use when troubleshooting this circuit.

8.After the coils have been tested, press and release the ON/OFF switch (either on DUAL brewers) located on the front switch panel. This will exit the TEST FREQUENCY function and return to the

MAIN SCREEN.

NOTE: If the operator wishes to test more than one function in the SERVICE TOOLS section (outputs, switches, servers, or coil frequency), it is not necessary to exit the program. Use the flow chart for SERVICE TOOLS to navigate to a particular function.

TINGS. This screen will alternate with ARE YOU SURE?.

4.Pressing NO in the confirmation screen will revert to MAIN SCREEN, without resetting the brewing setups to the defaults. Press YES to load the de- faults. This will then revert to the MAIN SCREEN, and the factory default values will replace all previously entered values. It will NOT reset the summation Brew counter.

SEL BREWER TYPE?

NO YES

ThermoF SoftHeat

DONE

FACTORY DEFAULTS

NO YES

EXIT

WILL REPLACE ALL

BREW SETTINGS

ARE YOU SURE?

NO YES

FACTORY DEFAULTS

This function allows the operator to erase all of the previously entered recipes and ad messages. Factory- set default values will replace all previous settings.

Procedure to set factory defaults:

1.Press and hold the upper right hidden switch until UNITS appears. Release the switch. Press and release the upper right hidden switch until the display reads SEL BREWER TYPE?.

2.Pressing NO in this screen will advance to FACTORY DEFAULTS. Press and release YES. The display should read ThermoF SoftHeat. The selected brewer type will be flashing. When correct brewer type is selected press DONE.

3.The display should now read FACTORY DEFAULTS. Pressing NO in this screen will revert to the MAIN SCREEN. Press YES to replace the defaults. This advances to WILL REPLACE ALL BREWING SET-

Page 38

EXIT

P2312

REPLACE

41341 080108

Image 38
Contents Dual SH DBC BUNN-O-MATIC Commercial Product Warranty Introduction Glossary Programming Switches ProgrammingOutputs Programming Lockout Switch mounted on main control boardScreen Main ScreenRecipe Programing Methods Using a Smart Funnel and a G9-2T DBC or MHG GrinderNot using a Smart Funnel and/or a G9-2T DBC or MHG Grinder RecipesLevel Continue toProgram Flow Diagram Program Flow Diagram Units Setting Units of Measure Procedure for modifying units of measureEnable Energysavr NEW Recipe ?Procedure for Setting the Recipe SET NEW RecipeSET NEW Recipe Sizes DONE?Procedure to program the coffee name SET NEW RecipesReview RECIPES? No YES Review Recipes Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee FavorsProcedure for reviewing recipes WAS the Last RecipeBrew OZ Setting or Adjusting Brew VOL- Umes Batches DONE? No YESBypass SET Pulse Brew Modifying pulse brewSET Pulse Brew SET Pulse Brew Easy Pulse Setup DONE? SET Pulse Brew Enter TimesTIMES? SET Preinfusion Batches DONE?Drip Time now displayed on non funnel lock units as well Procedure to modify drip timesSetup Complete Assign Recipes Procedure to copy settingsReads Copy Settings OnlyAre YOU SURE? Enable ADS?YOU SURE? SET TempSET Ready Procedure to set ready temperatureSET Temp Refill Range 20 toSpray OZ/M Dual Brewers Procedure to adjust the flow rate settingSpray OZ/M Single Brewers Bypass OZ/M Single Brewers Bypass OZ/M Dual BrewersCalibrate Flow ? Procedures to calibrate the sprayhead flow rateCalibrate Flow Procedures to calibrate the bypass flow rate Brate Bypass .. Press Brew to StartProcedures to view/reset the brew counters Brew CountersServer not in Place Server DetectFunnel Detect Service Tools Programming the Brewer Nothing Pressed SERVERS?Test FREQUENCY? Factory DefaultsProcedure to set factory defaults