Bunn SNG0033000 manual Bypass OZ/M Single Brewers, Bypass OZ/M Dual Brewers

Page 30

PROGRAMMING THE BREWER (cont.)

BYPASS OZ/M (SINGLE BREWERS)

This function allows the operator to view or to enter the actual flow rate coming out of the bypass nozzle. This is NOT used to change the actual flow rate, but to tell the internal controller how fast the water is flowing. The unit of measure is ounces per minute.

Procedure to adjust the flow rate setting:

1.Press and hold the upper right hidden switch until the display reads UNITS. Release the switch, then press and release switch until the display reads BYPAS OZ/M. The number represents what the brewer thinks is the flow rate of the bypass valve in ounces per minute.

2.If the actual flow rate of the bypass valve is known, but is different than the number on the display, use the (-)and (+) to enter the correct flow rate in ounces per minute.

3.When finished, press and release DONE. This saves the new setting and advances to the next function screen, CALIBRATE FLOW. Another alternative is to press the ON/OFF switch located on the front switch panel to exit the BYPASS OZ/M function and return to the MAIN SCREEN.

BYPS OZ/M: XX.X (-) DONE (+)

CALIBRATE FLOW?

NO YES

BYPASS OZ/M (DUAL BREWERS)

This function allows the operator to view or to enter the actual flow rate coming out of the bypass nozzle. This is NOT used to change the actual flow rate, but to tell the internal controller how fast the water is flowing. The unit of measure is ounces per minute.

Procedure to adjust the flow rate setting:

1.Press and hold upper right hidden switch until display reads UNITS. Release switch. Continue to press and release switch until display reads L BYPASS OZ/M. The number represents what the brewer thinks is the flow rate of the bypass valve in ounces per minute.

2.If the actual flow rate of the bypass valve is known, but is different than the number on the display, use the (-)and (+) to enter the correct flow rate in ounces per minute.

3.When finished, press and release the DONE. This saves the new setting and advances to R BYPS OZ/M. When finished setting right side, press and release DONE to advance to next function screen, CALIBRATE FLOW. Another alternative is to press and release either ON/OFF switch located on the front switch panel to exit the BYPASS OZ/M func- tion and return to the MAIN SCREEN.

L BYPS OZ/M: XX.X (-) DONE (+)

R BYPS OZ/M: XX.X (-) DONE (+)

CALIBRATE FLOW?

NO YES

Page 30

41341 080108

 

Image 30
Contents Dual SH DBC BUNN-O-MATIC Commercial Product Warranty Introduction Glossary Programming Switches ProgrammingOutputs Programming Lockout Switch mounted on main control boardScreen Main ScreenRecipe Programing Methods Using a Smart Funnel and a G9-2T DBC or MHG GrinderNot using a Smart Funnel and/or a G9-2T DBC or MHG Grinder RecipesLevel Continue toProgram Flow Diagram Program Flow Diagram Units Setting Units of Measure Procedure for modifying units of measureEnable Energysavr NEW Recipe ?Procedure for Setting the Recipe SET NEW RecipeSET NEW Recipe Sizes DONE?Procedure to program the coffee name SET NEW RecipesReview RECIPES? No YES Review Recipes Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee FavorsProcedure for reviewing recipes WAS the Last RecipeBrew OZ Setting or Adjusting Brew VOL- Umes Batches DONE? No YESBypass SET Pulse Brew Modifying pulse brewSET Pulse Brew SET Pulse Brew Easy Pulse Setup SET Pulse Brew Enter Times TIMES?DONE? SET Preinfusion Batches DONE?Procedure to modify drip times Setup CompleteDrip Time now displayed on non funnel lock units as well Assign Recipes Procedure to copy settingsReads Copy Settings Only Are YOU SURE? Enable ADS? YOU SURE? SET TempSET Ready Procedure to set ready temperatureSET Temp Refill Range 20 toProcedure to adjust the flow rate setting Spray OZ/M Single BrewersSpray OZ/M Dual Brewers Bypass OZ/M Single Brewers Bypass OZ/M Dual BrewersProcedures to calibrate the sprayhead flow rate Calibrate FlowCalibrate Flow ? Procedures to calibrate the bypass flow rate Brate Bypass .. Press Brew to StartProcedures to view/reset the brew counters Brew CountersServer Detect Funnel DetectServer not in Place Service Tools Programming the Brewer Nothing Pressed SERVERS?Factory Defaults Procedure to set factory defaultsTest FREQUENCY?