PROGRAMMING THE BREWER (cont.)

SET PREINFUSION:

This function sets the brewer to turn the sprayhead flow on for a preset time (1st ON TIME) followed by a preset spray pause (OFF TIMES) and then turn the spray on continuously until the brew volume is completed.

This is a special case of pulse brew. It is not pos- sible to set a batch size to have both pulse brew and preinfusion. One or the other (or neither) must be chosen. However, it is possible to set one batch size to pulse brew and the other two to preinfusion or vice versa.

NOTE: The procedure to enter the PULSE BREW function must be performed prior to following the steps listed below.

1.Press and release YES. The display should now read EASY PULSE SETUP.

2.Press and release NO. The display will read ENTER

TIMES?

3.Press YES to proceed. The display should now read 1st ON TIME X:XX.

4.Using (-)and (+) set the amount of time the flow of water into the funnel will be on.

5.When finished, press DONE. The display will now read OFF TIMES: X:XX.

6.Using (-)and (+) set the amount of time the flow of water into the funnel will be off.

7.When finished, press DONE. The display will now read LAST ON: PreI

8.If the display shows a time use (-)and (+) to set it to read PreI. (PreI is an abreviation for preinfu- sion)

9.When finished, press DONE. The display will show the two settings and PreI just entered for that batch size. After a 5 second delay, the display will read

3 BATCHES DONE?

10.If other batch sizes need to be modified, press

NO.

12.Press a different batch size pad and repeat steps 3 through 7. Repeat until all the desired batch sizes are set for the left side.

13.When finished press YES in 3 BATCHES DONE?. The display will then read DRIP TIME.

14.Press and release the ON/OFF switch (either on DUAL brewers) located on the front switch panel to exit the SET PULSE BREW function and return to the MAIN SCREEN.

NOTE: Pressing the upper right hidden switch before reaching the final setting screen exits the setup and retains the old values.

SET PULSE BREW?

 

NO

YES

 

EASY PULSE SETUP

 

NO

YES

EXIT TO

 

 

 

 

NEXT FUNCTION

 

 

SCREEN

ENTER TIMES?

 

NO

YES

 

1st ON TIME X:XX (-) DONE (+)

OFF TIMES: X:XX (-) DONE (+)

LAST ON: Prel (-) DONE (+)

1st OFF LAST XX.X XX.X Prel

5 SEC. DELAY

3 BATCHES DONE?

NO YES

EXIT TO

NEXT FUNCTION

SCREEN

Page 24

41341 080108

 

Image 24
Contents Dual SH DBC BUNN-O-MATIC Commercial Product Warranty Introduction Glossary Programming Switches ProgrammingProgramming Lockout Switch mounted on main control board ScreenOutputs Main ScreenUsing a Smart Funnel and a G9-2T DBC or MHG Grinder Not using a Smart Funnel and/or a G9-2T DBC or MHG GrinderRecipe Programing Methods RecipesLevel Continue toProgram Flow Diagram Program Flow Diagram Units Setting Units of Measure Procedure for modifying units of measureEnable Energysavr NEW Recipe ?Procedure for Setting the Recipe SET NEW RecipeSET NEW Recipe Sizes DONE?Procedure to program the coffee name SET NEW RecipesReview RECIPES? No YES Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee Favors Procedure for reviewing recipesReview Recipes WAS the Last RecipeBrew OZ Setting or Adjusting Brew VOL- Umes Batches DONE? No YESBypass SET Pulse Brew Modifying pulse brewSET Pulse Brew SET Pulse Brew Easy Pulse Setup SET Pulse Brew Enter Times TIMES?DONE? SET Preinfusion Batches DONE?Procedure to modify drip times Setup CompleteDrip Time now displayed on non funnel lock units as well Procedure to copy settings Reads Copy SettingsAssign Recipes OnlyEnable ADS? YOU SURE?Are YOU SURE? SET TempProcedure to set ready temperature SET TempSET Ready Refill Range 20 toProcedure to adjust the flow rate setting Spray OZ/M Single BrewersSpray OZ/M Dual Brewers Bypass OZ/M Single Brewers Bypass OZ/M Dual BrewersProcedures to calibrate the sprayhead flow rate Calibrate FlowCalibrate Flow ? Procedures to calibrate the bypass flow rate Brate Bypass .. Press Brew to StartProcedures to view/reset the brew counters Brew CountersServer Detect Funnel DetectServer not in Place Service Tools Programming the Brewer Nothing Pressed SERVERS?Factory Defaults Procedure to set factory defaultsTest FREQUENCY?