Bunn SNG0033000 manual Bypass

Page 19

PROGRAMMING THE BREWER (cont.)

% BYPASS

This function allows adjustment of the amount of water that bypasses the grounds. The number signi- fies the percentage of the brew volume which does not flow over the coffee grounds.

Modifying recipes - bypass percentages: Range: 0% to 90% for all three batch sizes

NOTE: If the brewer is already in the % BYPASS screen, it is not necessary to follow steps 1 through 6 in this section, but proceed directly to step 7.

1.Press and hold the upper right hidden switch (®) until the display reads UNITS. Release the switch, then press and release the switch until the display reads REVIEW RECIPES.

2.Press YES to proceed. The display should now read:

NO NAME, along with MODIFY, SHOW and NEXT (SINGLE brewers)

NO-NAME LEFT, along with MODIFY, SHOW and NEXT (DUAL brewers).

3.Press and release NEXT to advance to the desired

EXIT TO

NEXT FUNCTION

SCREEN

coffee name to be modified.

4.Press and release MODIFY. The display should read BREW OZ.

5.Press and release DONE. The display should read 3 BATCHES DONE?.

6.Press and release YES. The display should now read % BYPASS, and a batch light will be blinking. Press and release the batch size to be modified.

7.Using (-)and (+) set the amount of bypass water (percentage) to be dispensed around the grounds for that particular batch size.

8.When finished, press another batch size and repeat step 7 for each batch to be modified.

9.When finished setting all batch sizes, press DONE. The display should read 3 BATCHES DONE?

10.If they are not correct, press and release NO to return to the % BYPASS setup screen.

11.If the 3 batch sizes are correct, press YES. This will advance to SET PULSE BREW. Another alternative is to press the ON/OFF switch (either on DUAL brewers) to exit % BYPASS setup and return to the MAIN SCREEN.

REVIEW RECIPES?

NOYES

SINGLE DUAL

BREWERS BREWERS

NO-NAME

NO-NAME LEFT

MODIFY SHOW NEXT

MODIFY SHOW NEXT

% BYPASSS XX.X (-) DONE (+)

3 BATCHES DONE?

NO YES

SET PULSE BREW?

NO YES

BREW OZ. XX.X (-) DONE (+)

3 BATCHES DONE?

NO YES

SEE MODIFYING

PULSE BREW ON

THE FOLLOWING PAGE

OR PRESS AND RELEASE

ON/OFF SWITCH TO EXIT THE

%BYPASS SETUP AND RETURN TO THE MAIN SCREEN

ADVANCES TO ALL OTHER

COFFEE NAMES PROGRAMMED

IN THE BREWER"S MEMORY

(COFFEE NAME)

MODIFY SHOW NEXT

WHEN THE LAST COFFEE

NAME IN BREWER'S MEMORY

IS DISPLAYED, PRESSING NEXT WILL EXIT AND THE DISPLAY WILL THEN READ:

THAT WAS THE

LAST RECIPE

Page 19

41341 080108

 

Image 19
Contents Dual SH DBC BUNN-O-MATIC Commercial Product Warranty Introduction Glossary Programming Programming SwitchesMain Screen Programming Lockout Switch mounted on main control boardScreen OutputsRecipes Using a Smart Funnel and a G9-2T DBC or MHG GrinderNot using a Smart Funnel and/or a G9-2T DBC or MHG Grinder Recipe Programing MethodsContinue to LevelProgram Flow Diagram Program Flow Diagram Procedure for modifying units of measure Units Setting Units of MeasureNEW Recipe ? Enable EnergysavrSET NEW Recipe Procedure for Setting the RecipeSizes DONE? SET NEW RecipeSET NEW Recipes Procedure to program the coffee nameReview RECIPES? No YES WAS the Last Recipe Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee FavorsProcedure for reviewing recipes Review RecipesBatches DONE? No YES Brew OZ Setting or Adjusting Brew VOL- UmesBypass Modifying pulse brew SET Pulse BrewSET Pulse Brew SET Pulse Brew Easy Pulse Setup TIMES? SET Pulse Brew Enter TimesDONE? Batches DONE? SET PreinfusionSetup Complete Procedure to modify drip timesDrip Time now displayed on non funnel lock units as well Only Procedure to copy settingsReads Copy Settings Assign RecipesSET Temp Enable ADS?YOU SURE? Are YOU SURE?Refill Range 20 to Procedure to set ready temperatureSET Temp SET ReadySpray OZ/M Single Brewers Procedure to adjust the flow rate settingSpray OZ/M Dual Brewers Bypass OZ/M Dual Brewers Bypass OZ/M Single BrewersCalibrate Flow Procedures to calibrate the sprayhead flow rateCalibrate Flow ? Brate Bypass .. Press Brew to Start Procedures to calibrate the bypass flow rateBrew Counters Procedures to view/reset the brew countersFunnel Detect Server DetectServer not in Place Service Tools Programming the Brewer SERVERS? Nothing PressedProcedure to set factory defaults Factory DefaultsTest FREQUENCY?