Hoshizaki Comprehensive Guide to LED Lights and Alarm Safeties in Refrigerators

Page 18

f) LED Lights and Audible Alarm Safeties

The red LED indicates proper control voltage and will remain on unless a control voltage problem occurs. At startup a 5 second delay occurs while the board conducts an internal timer check. A short beep occurs when the power switch is turned OFF.

The green LEDs 1 through 4 energize and sequence from initial startup as listed in the table below. Note that the order of the LEDs from the outer edge of the board is 1, 4, 3, 2. For more information, see "II.B. Sequence of Operation."

Sequence Step

LED

Energized

 

Time LEDs are On

Components

Min.

Max.

Avg.

 

 

 

 

 

1 Minute Fill Cycle

4

WV

 

 

60 seconds

Harvest Cycle

1, 4, and 2

WV, HGV,

2 minutes

20 minutes

3 to 5 minutes

 

 

Comp, FMR

 

 

 

Freeze Cycle

1

Comp, PM,

5 minutes

freeze timer

30 to 35 minutes

 

 

FMR/FMS,

 

setting

 

 

 

LLV

 

 

 

Reverse Pump Out

1, 3, and 2

Comp, HGV,

10 seconds

20 seconds

factory setting

 

 

PM, FMR

 

 

 

 

 

 

 

 

 

The built in safeties shut down the unit and have alarms as follows:

No. of Beeps

Type of Alarm

Notes

(every 3 sec.)

 

 

 

 

 

1

High Evaporator Temp.

Check for harvest problem (stuck HGV or

 

(temperature > 127°F)

relay), hot water entering unit, stuck HM,

 

(53°C)

or shorted thermistor.

 

 

 

2

Harvest Backup Timer

Orange LED marked H TIMER lights up.

 

(harvest > 20 min. for two

Check for open thermistor, HGV not

 

cycles in a row)

opening, TXV leaking by, low charge, or

 

 

inefficient compressor.

 

 

 

3

Freeze Timer

Yellow LED marked F TIMER lights up.

 

(freeze > specified setting

Check for F/S stuck closed (up), WV

 

for two cycles in a row)

leaking by, HGV leaking by, TXV not

 

Timer is factory set using

feeding properly, low charge, HM not

 

dip switches 9 & 10

bypassing, or inefficient compressor.

 

 

 

To manually reset the above safeties, press the alarm reset button with the power supply on.

6

Low Voltage

Red LED will turn off if voltage protection

 

(92Vac ±5% or less)

operates.

 

 

The control voltage safeties automatically

7

High Voltage

reset when voltage is corrected.

 

(147Vac ±5% or more)

 

 

 

 

 

Legend: Comp–compressor; FMR–remote fan motor; FMS–self-contained fan motor; F/S–float switch; HGV–hot gas valve; HM–headmaster (C.P.R.); LLV–Liquid Line Valve; PM–pump motor; TXV–thermostatic expansion valve; WV–inlet water valve

18

Image 18
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Page Specifications Icemaker KM-650MAH air-cooledKM-650MWH water-cooled Water Cooled CondenserKM-650MRH remote air-cooled Condensing Unit URC-5FSpecifications Model URC-5FII. General Information Construction KM-650MWH water-cooled KM-650MRH remote air-cooled Sequence of Operation Cycle Steps Harvest Cycle Freeze Cycle One Minute Control Board Control Products E Control Board Control Board LayoutControl Board Features Maximum Water Supply Period 6 minutesLED Lights and Audible Alarm Safeties Controls and Adjustments Default Dip Switch SettingsHarvest Timer dip switch 1 Pump-Out Frequency Control dip switch 5 Control Board Check Procedure Control Board ReplacementKM-650MAH air-cooled KM-650MWH water-cooled KM-650MRH remote air-cooled Wiring Diagrams KM-650MAH air-cooled and KM-650MWH water-cooledPsig Performance Data 108680 615 IV. Service Diagnosis Minute KM Diagnostic Procedure Diagnostic Charts No Ice ProductionProblem Possible Cause Remedy Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Low Ice Production Abnormal IceOther Problem Possible Cause Remedy Refrigerant Recovery Removal and Replacement of ComponentsService for Refrigerant Lines Evacuation and Recharge R-404ARemoval and Replacement of Compressor BrazingRemoval and Replacement of Drier Removal and Replacement of Expansion Valve Removal and Replacement of Hot Gas Valve and Line Valve Removal and Replacement of Evaporator Adjustment of Water Regulating Valve Water-Cooled Model Only Page Removal and Replacement of Thermistor Removal and Replacement of Fan MotorRemoval and Replacement of Inlet Water Valve Removal and Replacement of Pump MotorRemoval and Replacement of Spray Tubes VI. Cleaning and Maintenance Instructions Cleaning and Sanitizing ProceduresCleaning Procedure Maintenance Sanitizing Procedure Following Cleaning ProcedureStainless Steel Exterior Air Filters air-cooled models only Preparing the Icemaker for Long StorageStorage Bin and Scoop Condenser air-cooled and remote air-cooled models onlyDrain the potable water supply line Drain the potable water tank