Hoshizaki KM-650MWH, KM-650MAH, KM-650MRH service manual 680

Page 29

2. KM-650MWH (water-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

70/21

680

308

 

675

306

 

626

284

 

 

 

 

80/27

676

307

 

668

303

 

595

270

 

 

 

 

90/32

675

306

 

662

300

 

598

271

lbs./day

 

kg./day

100/38

651

295

 

647

294

 

540

245

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1020

 

 

1029

 

 

1036

CONSUMPTION

80/27

 

1027

 

 

1040

 

 

1044

 

 

 

 

90/32

 

1029

 

 

1050

 

 

1055

watts

 

 

 

100/38

 

1028

 

 

1051

 

 

1060

APPROXIMATE WATER

70/21

662

2.51

 

729

2.76

 

1173

4.44

CONSUMPTION PER 24 HR.

80/27

713

2.70

 

817

3.09

 

1457

5.52

 

 

 

 

90/32

729

2.76

 

890

3.37

 

1457

5.52

gal./day

 

m3/day

100/38

980

3.71

 

1023

3.87

 

1977

7.49

FREEZING CYCLE TIME

70/21

 

27

 

 

28

 

 

30

 

 

 

 

80/27

 

28

 

 

30

 

 

32

 

 

 

 

90/32

 

28

 

 

31

 

 

33

min.

 

 

 

100/38

 

29

 

 

31

 

 

35

HARVEST CYCLE TIME

70/21

 

4.7

 

 

4.1

 

 

3.7

 

 

 

 

80/27

 

4.3

 

 

3.4

 

 

3.1

 

 

 

 

90/32

 

4.1

 

 

2.8

 

 

2.5

min.

 

 

 

100/38

 

3.4

 

 

2.7

 

 

2.1

HEAD PRESSURE

70/21

231

16.2

 

231

16.2

 

238

16.7

 

 

 

 

80/27

231

16.2

 

231

16.2

 

242

17.0

 

 

 

 

90/32

231

16.2

 

231

16.2

 

240

16.9

PSIG

kg/cm2G

100/38

235

16.5

 

233

16.4

 

249

17.5

SUCTION PRESSURE

70/21

50

3.5

 

51

3.6

 

53

3.7

 

 

 

 

80/27

51

3.6

 

54

3.8

 

54

3.8

 

 

 

 

90/32

51

3.6

 

56

3.9

 

56

4.0

PSIG

kg/cm2G

100/38

51

3.6

 

56

3.9

 

57

4.0

TOTAL HEAT OF REJECTION FROM CONDENSER

10,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

1,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

WATER FLOW FOR CONDENSER

77 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]

PRESSURE DROP OF COOLING WATER LINE

less than 10 PSIG

Note:

1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

29

Image 29
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Page KM-650MAH air-cooled Specifications IcemakerWater Cooled Condenser KM-650MWH water-cooledKM-650MRH remote air-cooled URC-5F Condensing UnitModel URC-5F SpecificationsII. General Information Construction KM-650MWH water-cooled KM-650MRH remote air-cooled Sequence of Operation Cycle Steps Harvest Cycle Freeze Cycle One Minute Control Board Control Board Control Products E Control BoardControl Board Layout Maximum Water Supply Period 6 minutes FeaturesLED Lights and Audible Alarm Safeties Default Dip Switch Settings Controls and AdjustmentsHarvest Timer dip switch 1 Pump-Out Frequency Control dip switch 5 Control Board Replacement Control Board Check ProcedureKM-650MAH air-cooled KM-650MWH water-cooled KM-650MRH remote air-cooled KM-650MAH air-cooled and KM-650MWH water-cooled Wiring DiagramsPsig 108 Performance Data680 615 IV. Service Diagnosis Minute KM Diagnostic Procedure No Ice Production Diagnostic ChartsProblem Possible Cause Remedy Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Other Low Ice ProductionAbnormal Ice Problem Possible Cause Remedy Service for Refrigerant Lines Removal and Replacement of ComponentsRefrigerant Recovery Evacuation and Recharge R-404ABrazing Removal and Replacement of CompressorRemoval and Replacement of Drier Removal and Replacement of Expansion Valve Removal and Replacement of Hot Gas Valve and Line Valve Removal and Replacement of Evaporator Adjustment of Water Regulating Valve Water-Cooled Model Only Page Removal and Replacement of Fan Motor Removal and Replacement of ThermistorRemoval and Replacement of Pump Motor Removal and Replacement of Inlet Water ValveRemoval and Replacement of Spray Tubes Cleaning and Sanitizing Procedures VI. Cleaning and Maintenance InstructionsCleaning Procedure Stainless Steel Exterior MaintenanceSanitizing Procedure Following Cleaning Procedure Storage Bin and Scoop Preparing the Icemaker for Long StorageAir Filters air-cooled models only Condenser air-cooled and remote air-cooled models onlyDrain the potable water tank Drain the potable water supply line