Hoshizaki KM-650MWH, KM-650MAH Preparing the Icemaker for Long Storage, Storage Bin and Scoop

Page 53

damp cloth containing a neutral cleaner to wipe off oil or dirt build up.

2.Storage Bin and Scoop

Wash your hands before removing ice. Use the plastic scoop provided (bin accessory).

The storage bin is for ice use only. Do not store anything else in the bin.

Keep the scoop clean. Clean it by using a neutral cleaner and rinse thoroughly.

Clean the bin liner by using a neutral cleaner. Rinse thoroughly after cleaning.

3.Air Filters (air-cooled models only)

The plastic mesh air filters located behind the louvers remove dirt or dust from the air, and keep the condenser from getting clogged. As the filters get clogged, the icemaker’s performance will be reduced. Check the filters at least twice a month. When they are clogged, use warm water and a neutral cleaner to wash the filters.

4. Condenser (air-cooled and remote air-cooled models only)

Check the condenser once a year, and clean if required by using a brush or vacuum cleaner. More frequent cleaning may be required depending on the location of the icemaker or condenser unit.

C. Preparing the Icemaker for Long Storage

WARNING

When shutting off the icemaker for an extended time, drain out all water from the water tank and remove the ice from the storage bin. The storage bin should be cleaned and dried. Drain the icemaker to prevent damage to the water supply line at subfreezing temperatures, using air or carbon dioxide. Shut off the icemaker until the proper ambient temperature is resumed.

When the icemaker is not used for two or three days, it is sufficient to only move the control switch to the "OFF" position, unless the icemaker will be at subfreezing temperatures.

1.On water-cooled model only, first remove the water from the water-cooled condenser:

1)Remove the front panel.

2)Move the control switch on the control box to the "OFF" position.

3)Wait 3 minutes.

4)Move the control switch to the "ICE" position.

5)Allow 5 minutes for the icemaker to fill with water and the water pump to start operating.

6)Close the water-cooled condenser water supply line shut-off valve.

7)Open the drain valve for the water-cooled condenser water supply line.

8)Allow the line to drain by gravity.

9)Quickly attach compressed air or carbon dioxide supply to the condenser water line drain valve.

53

Image 53
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Page KM-650MAH air-cooled Specifications IcemakerWater Cooled Condenser KM-650MWH water-cooledKM-650MRH remote air-cooled URC-5F Condensing UnitModel URC-5F SpecificationsII. General Information Construction KM-650MWH water-cooled KM-650MRH remote air-cooled Sequence of Operation Cycle Steps Harvest Cycle Freeze Cycle One Minute Control Board Control Board Control Products E Control BoardControl Board Layout Maximum Water Supply Period 6 minutes FeaturesLED Lights and Audible Alarm Safeties Default Dip Switch Settings Controls and AdjustmentsHarvest Timer dip switch 1 Pump-Out Frequency Control dip switch 5 Control Board Replacement Control Board Check ProcedureKM-650MAH air-cooled KM-650MWH water-cooled KM-650MRH remote air-cooled KM-650MAH air-cooled and KM-650MWH water-cooled Wiring DiagramsPsig 108 Performance Data680 615 IV. Service Diagnosis Minute KM Diagnostic Procedure No Ice Production Diagnostic ChartsProblem Possible Cause Remedy Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Other Low Ice ProductionAbnormal Ice Problem Possible Cause Remedy Service for Refrigerant Lines Removal and Replacement of ComponentsRefrigerant Recovery Evacuation and Recharge R-404ABrazing Removal and Replacement of CompressorRemoval and Replacement of Drier Removal and Replacement of Expansion Valve Removal and Replacement of Hot Gas Valve and Line Valve Removal and Replacement of Evaporator Adjustment of Water Regulating Valve Water-Cooled Model Only Page Removal and Replacement of Fan Motor Removal and Replacement of ThermistorRemoval and Replacement of Pump Motor Removal and Replacement of Inlet Water ValveRemoval and Replacement of Spray Tubes Cleaning and Sanitizing Procedures VI. Cleaning and Maintenance InstructionsCleaning Procedure Stainless Steel Exterior MaintenanceSanitizing Procedure Following Cleaning Procedure Storage Bin and Scoop Preparing the Icemaker for Long StorageAir Filters air-cooled models only Condenser air-cooled and remote air-cooled models onlyDrain the potable water tank Drain the potable water supply line