e)Pump-Out Frequency Control (dip switch 5 & 6)
The pump motor drains the water tank at the frequency set by the
The
Dip Switch Setting | Frequency | ||
No. 5 | No. 6 | ||
| |||
OFF | OFF | every cycle | |
ON | OFF | every 2 cycles | |
OFF | ON | every 5 cycles | |
ON | ON | every 10 cycles |
f) Freeze Timer (dip switch 9 & 10)
CAUTION
Adjust to proper specification, or the unit may not operate correctly.
The freeze timer setting determines the maximum allowed freeze time to prevent possible
The freeze timer is factory adjusted and no adjustment is required.
Dip Switch Setting | Time | |
No. 9 | No. 10 | (minutes) |
| ||
OFF | OFF | 60 |
|
|
|
OFF | ON | 50 |
ON | OFF | 70 |
ON | ON | 60 |
g) Bin Control
CAUTION
When the ambient temperature is below 45°F (7°C), the bin control thermostat operates to stop the icemaker even if the ice storage bin is empty. When the thermostat is set in the prohibited range, the icemaker operates continuously even if the ice storage bin is filled with ice. Setting in the prohibited range might cause severe damage to the icemaker resulting in failure.
No adjustment is required under normal use, as the bin control is
21