Hoshizaki KM-650MAH, KM-650MRH, KM-650MWH service manual Specifications, Model URC-5F

Page 9

Specifications

MODEL: URC-5F

AC SUPPLY VOLTAGE

115/60/1 (Connection to Icemaker)

 

FAN MOTOR

115 V

Total 1.3FLA

65W

 

 

 

EXTERIOR DIMENSIONS (WxDxH)

21-15/16" x 15-11/16" x 17-7/8" (557 x 398 x 454 mm)

DIMENSIONS INCLUDING LEGS (WxDxH)

24" x 18-1/8" x 32-13/16" (610 x 460 x 834 mm)

EXTERIOR FINISH

Galvanized Steel

 

 

 

 

WEIGHT

Net 61 lbs. ( 28 kg ) Shipping 68 lbs. ( 31 kg )

 

 

 

 

CONNECTIONS - ELECTRIC

Permanent - Connection

 

 

- REFRIGERANT

Discharge Line 1-1/16"-12 UNF Fitting (#10 AEROQUIP)

 

Liquid Line

5/8"-18 UNF Fitting (#6 AEROQUIP)

 

 

 

CONDENSER

Air-cooled, Fin and tube type

 

FAN MOTOR PROTECTION

Thermal Protection

 

 

REFRIGERANT CONTROL

Condensing Pressure Regulator

 

REFRIGERANT CHARGE

R-404A

1 lb. 14 oz.

(850g)

 

DESIGN PRESSURE

High 467 PSIG

 

 

 

 

 

 

OPERATING CONDITIONS

VOLTAGE RANGE

104 ~ 127 V

 

 

AMBIENT TEMP.

-20 ~ 122 °F

 

 

 

 

 

 

ACCESSORIES -SUPPLIED

Leg

 

 

2 pcs

 

Hex. Head Bolt w/Washer

8 x 16

8 pcs

 

Hex. Nut

 

8

8 pcs

 

 

 

 

 

DRAWING NO. (DIMENSION)

441211

 

 

 

 

 

 

 

 

Note: We reserve the right to make changes in specifications and design without prior notice.

Image 9
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Page KM-650MAH air-cooled Specifications IcemakerWater Cooled Condenser KM-650MWH water-cooledKM-650MRH remote air-cooled URC-5F Condensing UnitModel URC-5F SpecificationsII. General Information Construction KM-650MWH water-cooled KM-650MRH remote air-cooled Sequence of Operation Cycle Steps Harvest Cycle Freeze Cycle One Minute Control Board Control Products E Control Board Control Board LayoutControl Board Maximum Water Supply Period 6 minutes FeaturesLED Lights and Audible Alarm Safeties Default Dip Switch Settings Controls and AdjustmentsHarvest Timer dip switch 1 Pump-Out Frequency Control dip switch 5 Control Board Replacement Control Board Check ProcedureKM-650MAH air-cooled KM-650MWH water-cooled KM-650MRH remote air-cooled KM-650MAH air-cooled and KM-650MWH water-cooled Wiring DiagramsPsig 108 Performance Data680 615 IV. Service Diagnosis Minute KM Diagnostic Procedure No Ice Production Diagnostic ChartsProblem Possible Cause Remedy Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Low Ice Production Abnormal IceOther Problem Possible Cause Remedy Service for Refrigerant Lines Removal and Replacement of ComponentsRefrigerant Recovery Evacuation and Recharge R-404ABrazing Removal and Replacement of CompressorRemoval and Replacement of Drier Removal and Replacement of Expansion Valve Removal and Replacement of Hot Gas Valve and Line Valve Removal and Replacement of Evaporator Adjustment of Water Regulating Valve Water-Cooled Model Only Page Removal and Replacement of Fan Motor Removal and Replacement of ThermistorRemoval and Replacement of Pump Motor Removal and Replacement of Inlet Water ValveRemoval and Replacement of Spray Tubes Cleaning and Sanitizing Procedures VI. Cleaning and Maintenance InstructionsCleaning Procedure Maintenance Sanitizing Procedure Following Cleaning ProcedureStainless Steel Exterior Storage Bin and Scoop Preparing the Icemaker for Long StorageAir Filters air-cooled models only Condenser air-cooled and remote air-cooled models onlyDrain the potable water tank Drain the potable water supply line