Hoshizaki KM-650MAH, KM-650MWH service manual KM-650MRH remote air-cooled

Page 7

3. KM-650MRH (remote air-cooled)

AC SUPPLY VOLTAGE

208-230/60/1 (3 wire with neutral for 115V)

 

AMPERAGE

7.1 A ( 5 Min. Freeze AT 104°F / WT 80°F)

 

MINIMUM CIRCUIT AMPACITY

15 A

 

 

 

 

MAXIMUM FUSE SIZE

15 A

 

 

 

 

APPROXIMATE ICE PRODUCTION

Ambient

WATER TEMP. (°F)

 

PER 24 HR.

Temp.(°F)

50

70

 

90

lbs./day ( kg/day )

70

*615 (279)

597 (271)

 

556 (252)

Reference without *marks

80

601 (273)

574 (260)

 

523 (237)

 

90

597 (271)

*554 (251)

 

506 (230)

SHAPE OF ICE

100

583 (264)

543 (246)

 

462 (210)

Crescent Cube

 

 

 

 

ICE PRODUCTION PER CYCLE

14.1 lbs. (6.4 kg ) 720 pcs.

 

 

 

APPROXIMATE STORAGE CAPACITY

N/A

 

 

 

 

ELECTRIC & WATER CONSUMPTION

90/70°F

 

70/50°F

 

ELECTRIC W (kWH/100 lbs.)

1250(5.4)

 

1150(4.5)

 

 

WATER gal./24HR (gal./100 lbs.)

111(20.0)

 

266(43.2)

 

 

EXTERIOR DIMENSIONS (WxDxH)

22" x 27-3/8" x 37-7/16" (560 x 695 x 950 mm)

 

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

 

WEIGHT

Net 169 lbs. (77 kg), Shipping

200 lbs. (91 kg)

 

CONNECTIONS - ELECTRIC

Permanent - Connection

 

 

 

- WATER SUPPLY

Inlet

1/2" FPT

 

 

 

- DRAIN

Outlet

3/4" FPT

 

 

 

 

 

3/8" OD Tube

 

 

 

CUBE CONTROL SYSTEM

Float Switch

 

 

 

 

HARVESTING CONTROL SYSTEM

Hot Gas and Water, Thermistor and Timer

 

ICE MAKING WATER CONTROL

Timer Controlled. Overflow Pipe

 

COOLING WATER CONTROL

N/A

 

 

 

 

BIN CONTROL SYSTEM

Thermostat

 

 

 

 

COMPRESSOR

Hermetic, Model RS55C2E-CAV

 

CONDENSER

Air-cooled Remote, Condenser Unit URC-5F

 

EVAPORATOR

Vertical type, Stainless Steel and Copper

 

REFRIGERANT CONTROL

Thermostatic Expansion Valve

 

 

 

 

Condensing Pressure Regulator on URC-5F

 

REFRIGERANT CHARGE

R-404A,

5 lbs. 11 oz. (2580 g)

 

 

( Icemaker 3 lbs. 13 oz. Cond. Unit 1 lb. 14 oz. )

 

DESIGN PRESSURE

High 467 PSIG, Low 230 PSIG

 

 

 

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-out ( Internal )

 

COMPRESSOR PROTECTION

Auto-reset Overload Protector ( Internal )

 

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

 

LOW WATER PROTECTION

Float Switch

 

 

 

 

ACCESSORIES -SUPPLIED

N/A

 

 

 

 

-REQUIRED

Ice Storage Bin, Remote Condenser Unit

 

OPERATING CONDITIONS

VOLTAGE RANGE

 

 

187 - 253 V

 

AMBIENT TEMP.

 

 

45 -100° F

 

WATER SUPPLY TEMP.

 

 

45 - 90° F

 

WATER SUPPLY PRESSURE

 

10 - 113 PSIG

Note: We reserve the right to make changes in specifications and design without prior notice.

Image 7
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Page KM-650MAH air-cooled Specifications IcemakerWater Cooled Condenser KM-650MWH water-cooledKM-650MRH remote air-cooled URC-5F Condensing UnitModel URC-5F SpecificationsII. General Information Construction KM-650MWH water-cooled KM-650MRH remote air-cooled Sequence of Operation Cycle Steps Harvest Cycle Freeze Cycle One Minute Control Board Control Board Layout Control Products E Control BoardControl Board Maximum Water Supply Period 6 minutes FeaturesLED Lights and Audible Alarm Safeties Default Dip Switch Settings Controls and AdjustmentsHarvest Timer dip switch 1 Pump-Out Frequency Control dip switch 5 Control Board Replacement Control Board Check ProcedureKM-650MAH air-cooled KM-650MWH water-cooled KM-650MRH remote air-cooled KM-650MAH air-cooled and KM-650MWH water-cooled Wiring DiagramsPsig 108 Performance Data680 615 IV. Service Diagnosis Minute KM Diagnostic Procedure No Ice Production Diagnostic ChartsProblem Possible Cause Remedy Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Abnormal Ice Low Ice ProductionOther Problem Possible Cause Remedy Evacuation and Recharge R-404A Removal and Replacement of ComponentsService for Refrigerant Lines Refrigerant RecoveryBrazing Removal and Replacement of CompressorRemoval and Replacement of Drier Removal and Replacement of Expansion Valve Removal and Replacement of Hot Gas Valve and Line Valve Removal and Replacement of Evaporator Adjustment of Water Regulating Valve Water-Cooled Model Only Page Removal and Replacement of Fan Motor Removal and Replacement of ThermistorRemoval and Replacement of Pump Motor Removal and Replacement of Inlet Water ValveRemoval and Replacement of Spray Tubes Cleaning and Sanitizing Procedures VI. Cleaning and Maintenance InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure MaintenanceStainless Steel Exterior Condenser air-cooled and remote air-cooled models only Preparing the Icemaker for Long StorageStorage Bin and Scoop Air Filters air-cooled models onlyDrain the potable water tank Drain the potable water supply line
Related manuals
Manual 32 pages 59.37 Kb