Hoshizaki KM-650MWH Removal and Replacement of Thermistor, Removal and Replacement of Fan Motor

Page 47

K. Removal and Replacement of Thermistor

IMPORTANT

1.Fragile, handle very carefully.

2.Always use a recommended sealant (High Thermal Conductive Type), Model KE4560RTV manufactured by SHINETSU SILICONE, Part Code 60Y000- 11, or Part Code 4A0683-01 equivalent.

3.Always use a recommended foam insulation (Non-absorbent Type) or equivalent.

4.Do not shorten or cut the thermistor leads when installing.

1)Turn off the power supply.

2)Remove the panels.

3)Remove the control box cover.

4)Disconnect the thermistor leads from the K3 connector on the control board.

5)Remove the plastic cable ties, foam insulation, thermistor holder and thermistor. See Fig. 2.

6)Scrape away the old sealant on the thermistor holder and the suction pipe.

7)Wipe off moisture or condensation on the suction pipe.

Thermistor Lead

Cable Tie

Foam Insulation

Thermistor Holder

Fig. 2

8)Smoothly apply recommended sealant (KE4560RTV, Part Code 60Y000-11 or 4A068301) to the thermistor holder concave.

9)Attach the new thermistor to the suction pipe in the same position as the previous thermistor. Be very careful to prevent damage to the leads. Secure it using the thermistor holder and recommended foam insulation.

10)Secure the insulation using the plastic cable ties.

11)Connect the thermistor leads through the bushing of the control box to the K3 connector on the control board.

Note: Do not cut the leads of the thermistor while installing it.

12)Replace the control box cover and the panels in their correct positions.

13)Turn on the power supply.

L.Removal and Replacement of Fan Motor

Note: When replacing a fan motor with defective winding, it is recommended that a new capacitor be installed.

1)Turn off the power supply.

2)Remove the panels.

47

Image 47
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Page KM-650MAH air-cooled Specifications IcemakerWater Cooled Condenser KM-650MWH water-cooledKM-650MRH remote air-cooled URC-5F Condensing UnitModel URC-5F SpecificationsII. General Information Construction KM-650MWH water-cooled KM-650MRH remote air-cooled Sequence of Operation Cycle Steps Harvest Cycle Freeze Cycle One Minute Control Board Control Board Control Products E Control BoardControl Board Layout Maximum Water Supply Period 6 minutes FeaturesLED Lights and Audible Alarm Safeties Default Dip Switch Settings Controls and AdjustmentsHarvest Timer dip switch 1 Pump-Out Frequency Control dip switch 5 Control Board Replacement Control Board Check ProcedureKM-650MAH air-cooled KM-650MWH water-cooled KM-650MRH remote air-cooled KM-650MAH air-cooled and KM-650MWH water-cooled Wiring DiagramsPsig 108 Performance Data680 615 IV. Service Diagnosis Minute KM Diagnostic Procedure No Ice Production Diagnostic ChartsProblem Possible Cause Remedy Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Other Low Ice ProductionAbnormal Ice Problem Possible Cause Remedy Evacuation and Recharge R-404A Removal and Replacement of ComponentsService for Refrigerant Lines Refrigerant RecoveryBrazing Removal and Replacement of CompressorRemoval and Replacement of Drier Removal and Replacement of Expansion Valve Removal and Replacement of Hot Gas Valve and Line Valve Removal and Replacement of Evaporator Adjustment of Water Regulating Valve Water-Cooled Model Only Page Removal and Replacement of Fan Motor Removal and Replacement of ThermistorRemoval and Replacement of Pump Motor Removal and Replacement of Inlet Water ValveRemoval and Replacement of Spray Tubes Cleaning and Sanitizing Procedures VI. Cleaning and Maintenance InstructionsCleaning Procedure Stainless Steel Exterior MaintenanceSanitizing Procedure Following Cleaning Procedure Condenser air-cooled and remote air-cooled models only Preparing the Icemaker for Long StorageStorage Bin and Scoop Air Filters air-cooled models onlyDrain the potable water tank Drain the potable water supply line
Related manuals
Manual 32 pages 59.37 Kb