Hoshizaki KM-650MAH, KM-650MRH Drain the potable water supply line, Drain the potable water tank

Page 54

10)Blow the water-cooled condenser out, using compressed air or carbon dioxide until water stops coming out.

2.Drain the potable water supply line:

1)Remove the front panel.

2)Move the control switch on the control box to the "OFF" position.

3)Wait 3 minutes.

4)Close the potable water supply line shut-off valve and open the potable water supply line drain valve.

5)Allow the line to drain by gravity.

6)Attach compressed air or carbon dioxide supply to the potable water line drain valve.

7)Move the control switch to the "ICE" position.

8)Blow the potable water line out using compressed air or carbon dioxide.

3.Drain the potable water tank:

1)Turn off the power supply.

2)Move the control switch to the "OFF" position.

3)Remove the front panel and the base

cover, and then remove the insulation panel by lifting up the panel slightly and pulling it towards you.

5)Remove one end of the pump tubing (see Fig. 5). Drain the water tank. Replace the pump tubing in its correct position.

5) Remove all ice from the storage bin, and

Fig. 5

clean the storage bin.

 

7)Replace the front panel in its correct position.

8)Close the drain valve.

54

Image 54
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Page Specifications Icemaker KM-650MAH air-cooledKM-650MWH water-cooled Water Cooled CondenserKM-650MRH remote air-cooled Condensing Unit URC-5FSpecifications Model URC-5FII. General Information Construction KM-650MWH water-cooled KM-650MRH remote air-cooled Sequence of Operation Cycle Steps Harvest Cycle Freeze Cycle One Minute Control Board Control Products E Control Board Control Board LayoutControl Board Features Maximum Water Supply Period 6 minutesLED Lights and Audible Alarm Safeties Controls and Adjustments Default Dip Switch SettingsHarvest Timer dip switch 1 Pump-Out Frequency Control dip switch 5 Control Board Check Procedure Control Board ReplacementKM-650MAH air-cooled KM-650MWH water-cooled KM-650MRH remote air-cooled Wiring Diagrams KM-650MAH air-cooled and KM-650MWH water-cooledPsig Performance Data 108680 615 IV. Service Diagnosis Minute KM Diagnostic Procedure Diagnostic Charts No Ice ProductionProblem Possible Cause Remedy Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Low Ice Production Abnormal IceOther Problem Possible Cause Remedy Refrigerant Recovery Removal and Replacement of ComponentsService for Refrigerant Lines Evacuation and Recharge R-404ARemoval and Replacement of Compressor BrazingRemoval and Replacement of Drier Removal and Replacement of Expansion Valve Removal and Replacement of Hot Gas Valve and Line Valve Removal and Replacement of Evaporator Adjustment of Water Regulating Valve Water-Cooled Model Only Page Removal and Replacement of Thermistor Removal and Replacement of Fan MotorRemoval and Replacement of Inlet Water Valve Removal and Replacement of Pump MotorRemoval and Replacement of Spray Tubes VI. Cleaning and Maintenance Instructions Cleaning and Sanitizing ProceduresCleaning Procedure Maintenance Sanitizing Procedure Following Cleaning ProcedureStainless Steel Exterior Air Filters air-cooled models only Preparing the Icemaker for Long StorageStorage Bin and Scoop Condenser air-cooled and remote air-cooled models onlyDrain the potable water supply line Drain the potable water tank