Hoshizaki KM-650MRH, KM-650MAH, KM-650MWH Controls and Adjustments, Default Dip Switch Settings

Page 19

3. Controls and Adjustments

a)Default Dip Switch Settings

The dip switch is factory-adjusted to the following positions:

Dip Switch No.

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

KM-650MAH

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

KM-650MWH

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

KM-650MRH

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

Freeze Timer (9 & 10)

Normally in the OFF position.

Pump-Out Frequency Control (5 & 6)

Pump-Out Timer (3 & 4)

Harvest Timer (1 & 2)

b)Harvest Control – Thermistor

A thermistor (semiconductor) is used for a harvest control sensor. The resistance varies depending on the suction line temperatures. The thermistor detects the temperature of the evaporator outlet to start the harvest timer. No adjustment is required. If necessary, check for resistance between thermistor leads, and visually check the thermistor mounting, located on the suction line next to the evaporator outlet.

Temperature (°F)

Temperature (°C)

Resistance (k)

 

 

 

0

-18

14.401

10

-12

10.613

32

0

6.000

50

10

3.871

70

21

2.474

90

32

1.633

Check a thermistor for resistance by using the following procedure:

1)Disconnect the connector K3 on the board.

2)Remove the thermistor. See "V.K. Removal and Replacement of Thermistor."

3)Immerse the thermistor sensor portion in a glass containing ice and water for 2 or 3 minutes.

4)Check for a resistance between thermistor leads. Normal reading is within 3.5 to 7 k. Replace the thermistor if it exceeds the normal reading.

19

Image 19
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Page KM-650MAH air-cooled Specifications IcemakerWater Cooled Condenser KM-650MWH water-cooledKM-650MRH remote air-cooled URC-5F Condensing UnitModel URC-5F SpecificationsII. General Information Construction KM-650MWH water-cooled KM-650MRH remote air-cooled Sequence of Operation Cycle Steps Harvest Cycle Freeze Cycle One Minute Control Board Control Board Layout Control Products E Control BoardControl Board Maximum Water Supply Period 6 minutes FeaturesLED Lights and Audible Alarm Safeties Default Dip Switch Settings Controls and AdjustmentsHarvest Timer dip switch 1 Pump-Out Frequency Control dip switch 5 Control Board Replacement Control Board Check ProcedureKM-650MAH air-cooled KM-650MWH water-cooled KM-650MRH remote air-cooled KM-650MAH air-cooled and KM-650MWH water-cooled Wiring DiagramsPsig 108 Performance Data680 615 IV. Service Diagnosis Minute KM Diagnostic Procedure No Ice Production Diagnostic ChartsProblem Possible Cause Remedy Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Abnormal Ice Low Ice ProductionOther Problem Possible Cause Remedy Evacuation and Recharge R-404A Removal and Replacement of ComponentsService for Refrigerant Lines Refrigerant RecoveryBrazing Removal and Replacement of CompressorRemoval and Replacement of Drier Removal and Replacement of Expansion Valve Removal and Replacement of Hot Gas Valve and Line Valve Removal and Replacement of Evaporator Adjustment of Water Regulating Valve Water-Cooled Model Only Page Removal and Replacement of Fan Motor Removal and Replacement of ThermistorRemoval and Replacement of Pump Motor Removal and Replacement of Inlet Water ValveRemoval and Replacement of Spray Tubes Cleaning and Sanitizing Procedures VI. Cleaning and Maintenance InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure MaintenanceStainless Steel Exterior Condenser air-cooled and remote air-cooled models only Preparing the Icemaker for Long StorageStorage Bin and Scoop Air Filters air-cooled models onlyDrain the potable water tank Drain the potable water supply line