Hoshizaki IM-240AME Water-Cooled Model, Standard connections according to WRC regulations in U.K

Page 4

ENGLISH

Inlet Hose

Water Supply Inlet G3/4

Drain Outlet R3/4

 

Outlet Hose

Water

Supply Tap

Inlet Hose

Fig. 7

Fig. 8

[Water-Cooled Model]

*Hoshizaki recommends that the water-cooled Condenser should be connected to a closed circuit recirculating type cooling system utilizing a tower, water chiller or similar (see Fig. 15 and 16). Water make up should be via a ball valve/break tank arrangement.

*Whilst connecting a water-cooled Condenser to a mains water (potable) supply will not affect the performance of the machine, it will most certainly cause a high use/waste of a valuable resource and is not recommended.

*The services of a licensed or coded plumber should be used to ensure a correct installation.

*The connections should be made properly in compliance with the applicable national or local regulations.

[a]Standard connections according to WRC regulations in U.K. (Fig. 9 and 10)

*When selecting a Cooling Tower, refer to the following peak values of heat flow in the Condenser:

Model IM-240AWME:

5235 W

*Pipes between the Cooling Tower and the icemaker should be at least 20 mm DIA to reduce pressure loss, even though the icemaker fittings are 13 mm DIA.

*Pressure loss in the water circuit inside the unit will be 5 to 6 m when the cooling water flows at the ratio of 4 to 5 lit/min.

*Select a Circulating Pump referring to the above values of heat flow.

*Do not use a Cascade Pump, or the Water Regulator will vary the flow and stop it during the defrost cycle.

*The Strainer must be cleaned periodically.

[Icemaker Connections]

1) Attach the angled end of white flexible inlet hose (accessory) to the G3/4 fitting on the left side of the icemaker as indicated, ensuring rubber sealing washer is correctly positioned. Hand tighten sufficiently to provide leak free joint.

2) Attach the other end of inlet hose to the water tap (Fig. 8), noting washer is correctly positioned before hand tightening as above.

Note: If filtration or treatment is used, ensure icemaker section only is on treated water supply, not the Condenser.

3) Attach grey flexible outlet hose (accessory) to the R3/4 fitting on the rear of the icemaker as indicated (Fig. 9), confirming fitment of

rubber washer before finally hand tightening the joint. This pipe can be cut to length as necessary to suit position of main drain.

4)By means of a suitable spanner or wrench, tighten the 1/2-3/4 nipples (accessory) into the Rc1/2 fittings on the rear of the icemaker as indicated. P.T.F.E. tape and/or a suitable sealing compound should be used to obtain a leak free joint.

Note: Jointing compounds should be approved and suitable for potable water use.

5)Connect the Condenser cooling circuit to the free end of 1/2-3/4 nipples as indicated (Fig. 9) using a suitable rigid type pipe. P.T.F.E. tape and/or a suitable sealing compound should be used to obtain a leak free joint.

 

Icemaker

1/2-3/4 Nipple

Cooling Water

 

Inlet Rc1/2

 

Cooling Water

 

Outlet Rc1/2

 

Potable Water

 

Inlet G3/4

Inlet Hose

Condenser Cooling Circuit

 

 

Bin

 

Drain Outlet R3/4

Outlet Hose

 

Fig. 9

Flow Control Valve

Icemaker

 

Cooling

 

P

Tower

 

 

Strainer

Pump

 

 

Fig. 10

 

[b]Connections according to regulations other than WRC by utilising accessory hoses (Fig. 11)

1)Follow the instructions from 1) to 4) in [a] above.

2)For Condenser connections, use supplied accessory hoses and make the same connections as 1) to 3) in [a] above to the free end of 1/2-3/4 nipples as indicated (Fig. 11).

3

Image 4
Contents 89/336 73/23 Installation EnglishUnpacking LocationFor the U.K. and the Republic of Ireland only Water Supplyand Drain ConnectionsAir-Cooled Model Water-Cooled Model Standard connections according to WRC regulations in U.K.Icemaker BinSTART-UPPROCEDURE FinalchecksEmplacement FrançaisDeballage AvertissementBranchements DE L’ARRIVEE ET DE Lavidange D’EAU Modèle avec refroidissement par airMachine à glace Modèle avec refroidissement par eauBic Dernierscontroles Mise EN MarcheAuspacken DeutschAufstellen Wasserversorgungundrohranschlüsse Luftgekühltes ModellEisbereiter VorratsbehälterInbetriebnahme AbschliessendeprüfungenInstallatie NederlandsUitpakken LocatieAansluitingenvoorwatertoevoeren Waterafvoer Luchtgekoeld modelIJsmachine Watergekoeld modelBunker Startprocedure Laatste ControlesEspañol InstalacionImportante AdvertenciaSuministro DE Agua Y Conexiones DE Desague Modelo refrigerado por aireModelo refrigerado por agua Máquina de hieloConexiones estándar conforme a las normativas WRC En el Reino Unido Ilust y AlmacenamientoProcedimiento Paralapuestaen Marcha Últimas ComprobacionesInstallazione ItalianoAvvertenza AttenzioneCollegamentielettrici Avvertenza Collegamenti Peralimentazione E Scarico AcquaModello raffreddato ad aria Macchina Modello raffreddato ad acquaDeposito di Raccolta cubetti Proceduradiavviamento Controlli Finali92E1CG21C 050729