GEM0650/0956/1256 Remote

Auger Maintenance

Auger:

In some areas, the water supply to the ice machine will contain a high concentration of minerals, and that will result in an evaporator and auger becoming coated with these minerals, requiring a more frequent removal than twice per year. If in doubt about the condition of the evaporator and auger, the auger can be removed so the parts can be inspected.

Note: Water filters can filter out suspended solids, but not dissolved solids. “Soft” water may not be the complete answer. Check with a water treatment specialist regarding water treatment.

For more information on removal of these parts, see Removal and Replacement.

1. Disconnect electrical power to the ice machine.

2. Turn off the water supply to the ice machine.

3. To remove the auger, remove the front and top panels.

4.Push back the bail clamp holding the ice chute cover to the ice chute, and remove cover.

5.Remove ice chute from evaporator.

6.Remove four (4) Allen screws holding breaker to evaporator.

7.Drain the evaporator by lowering and uncapping the evaporator drain hose.

8.Pull up to remove the auger. After the auger has been removed, allow the auger to dry: if the auger is not bright and shinny, it must be cleaned.

9.Clean the auger and evaporator as required. DO NOT HONE THE EVAPORATOR.

10.Replace the water seal.

11.Reverse to reassemble.

Ice Sweep

Allen Screws

Breaker Cover

Breaker, Bearing

and Auger Assembly

Page 29

Image 35
Contents By Ice-O-Matic Pearl Ice SeriesPage Keep this manual for future reference IntroductionTable Of Contents Concealed Loss or Damage Freight Claim ProcedureInspect Promptly Visible Loss or DamageGoverning LAW WarrantyFor the Installer GEM0650/0956R GEM1256R Bin Application Ice Machine SpecificationsWater Limitations LocationStorage Bin Ice machineLine Sets ERC Dimensions Inches GRC1001 GRC1061 GCR2061Remote Condenser Pearl Ice NumberCalculation Example Remote Condenser LocationCalculation Formula Precharged Line Set Routing Remote Condenser LocationRoof Attachment Typical Installation Final Connections Coupling Instructions Initial ConnectionsDrains Ice Machine For the PlumberWater Inlet For the Electrician Completed Installation Final Check List Start Up There are no adjustments to make, so replace the panelsStart Up Pre-Start InspectionComponent Description Control Board GEM0650/0956/1256 Remote Electrical Sequence Water System Operation WaterWater Water LevelOperation Refrigeration Refrigeration SchematicLow Condensing Temperature Pump Down Operation Performance Sanitizing and Cleaning Brush in direction of fins Condenser MaintenanceBearing Maintenance Bearing MaintenanceWater Sensor Sensor MaintenanceBin Control Sensor Auger Auger MaintenanceSymptom Possible Cause Probable Correction Service DiagnosisSymptom High pressure cut out check Control System DiagnosticsBin Controls Ice Level Sensors Water Reservoir, Bin ControlWater Reservoir Bearing and Breaker To Remove the Breaker Bearing AssemblyTo Remove the Auger AugerReplacing the Water Seal Water SealTo Remove the Water Seal Removal of the Water Seal To Replace the Water SealTo Reassemble the Evaporator and Auger EvaporatorTo Replace the Evaporator To Inspect the Gear Motor To Remove and Repair the Gear Motor AssemblyGear Motor To Check the Gear MotorFan Blade and Motor To Remove the Condenser Fan Motor AssemblyCharging Procedure Refrigeration ServiceWiring Diagram GEM0650R GEM0650R Wiring DiagramWiring Diagram GEM0956R GEM0956R Wiring DiagramWiring Diagram GEM1256R GEM1256R Wiring DiagramWhat to Do Before Calling for Service Service History