Ice-O-Matic GEM1256R, GEM0956R, GEM0650R To Remove the Water Seal, Replacing the Water Seal

Page 42

GEM0650/0956/1256 Remote

R&R-Water Seal

To Remove the Water Seal:

(Assuming all steps to remove the auger have been performed)

1.The gear motor/evaporator assembly will have to be exposed.

2.Remove the four (4) hex head cap screws holding the evaporator to the gear motor assembly. Lift the evaporator up and off the gear motor.

3.Remove the snap ring or wire retainer from the groove under the water seal.

4.Pull or drive out the lower half of the water seal.

Removal of the Water Seal

To Replace the Water Seal:

1.Lubricate the water seal with water, and push the water seal into the bottom of the evaporator slightly past the groove for the snap ring.

2.Replace the snap ring and pull the water seal down against it.

3.The part of the water seal that rotates with the auger must also be

replaced. Remove the old part from the auger and clean the mounting area.

4.Place a small bead of food grade silastic sealant (Such as 732 RTV) on the area of the auger where the water seal is to be mounted.

5.Carefully push the water seal (Rubber side against the auger shoulder and the silastic.)

Caution: DO NOT get any silastic onto the face of the seal.

6.Allow the auger and seal to air dry until the silastic is dry on the surface.

7.If the original water seal was leaking, it would be a good idea to inspect the interior of the gear motor.

Replacing the Water Seal

Water

Seal

Retaining

Ring

Place Food

Grade Sealant

Here

Page 36

Image 42
Contents Pearl Ice Series By Ice-O-MaticPage Introduction Keep this manual for future referenceTable Of Contents Visible Loss or Damage Freight Claim ProcedureInspect Promptly Concealed Loss or DamageWarranty Governing LAWFor the Installer GEM0650/0956R GEM1256R Ice Machine Specifications Bin ApplicationIce machine LocationStorage Bin Water LimitationsPearl Ice Number ERC Dimensions Inches GRC1001 GRC1061 GCR2061Remote Condenser Line SetsRemote Condenser Location Calculation FormulaCalculation Example Remote Condenser Location Roof AttachmentPrecharged Line Set Routing Typical Installation Coupling Instructions Initial Connections Final ConnectionsFor the Plumber Water InletDrains Ice Machine For the Electrician Completed Installation Final Check List Pre-Start Inspection There are no adjustments to make, so replace the panelsStart Up Start UpComponent Description Control Board GEM0650/0956/1256 Remote Electrical Sequence Water Level Operation WaterWater Water SystemRefrigeration Schematic Operation RefrigerationLow Condensing Temperature Pump Down Operation Performance Sanitizing and Cleaning Condenser Maintenance Brush in direction of finsBearing Maintenance Bearing MaintenanceSensor Maintenance Bin Control SensorWater Sensor Auger Maintenance AugerService Diagnosis Symptom Possible Cause Probable CorrectionSymptom Control System Diagnostics High pressure cut out checkWater Reservoir, Bin Control Water ReservoirBin Controls Ice Level Sensors To Remove the Breaker Bearing Assembly Bearing and BreakerAuger To Remove the AugerRemoval of the Water Seal To Replace the Water Seal Water SealTo Remove the Water Seal Replacing the Water SealEvaporator To Replace the EvaporatorTo Reassemble the Evaporator and Auger To Check the Gear Motor To Remove and Repair the Gear Motor AssemblyGear Motor To Inspect the Gear MotorTo Remove the Condenser Fan Motor Assembly Fan Blade and MotorRefrigeration Service Charging ProcedureGEM0650R Wiring Diagram Wiring Diagram GEM0650RGEM0956R Wiring Diagram Wiring Diagram GEM0956RGEM1256R Wiring Diagram Wiring Diagram GEM1256RService History What to Do Before Calling for Service