Ice-O-Matic GEM0650R, GEM1256R, GEM0956R installation manual To Remove the Auger

Page 41

GEM0650/0956/1256 Remote

R&R-Auger

To Remove the Auger:

 

1.

Disconnect electrical power.

 

2.

Turn off the water to the machine.

 

3.

Unclip the evaporator drain hose, pull it down and drain the evaporator into the bin or

 

 

container.

 

4.

Remove the top panel.

 

5.

Swing bail clip down and remove the ice chute cover.

 

6.

Unscrew ice sweep.

 

7.

Remove ice chute body.

 

8.

The auger and breaker/bearing may now be removed as an assembly.

 

 

a. Unscrew four (4) Allen head cap screws holding breaker to evaporator.

 

 

b. Lift up on breaker and remove auger from evaporator.

 

Note: If the auger is stuck, the breaker must be removed from the auger.

9.The breaker may be removed from the auger and evaporator without disturbing the auger.

a.Unscrew breaker cover from the breaker. (Note: Left hand Threads)

b.Unscrew auger stud from top of auger.

c.Unscrew four (4) Allen head cap screws holding breaker to evaporator.

d.Lift up and remove breaker from evaporator.

e.If the auger is stuck, use a slide hammer type of puller to pull on the auger at the threaded hole. The size of that hole is 5/8”-18.

10.Inspect the auger, the critical areas of the auger are:

a.The auger body. It should be clean and shining. Sometimes an auger will appear clean when wet, but after it is dry it will be seen to be stained. Scrub the auger with ice machine cleaner and hot water.

b.The water seal area. Because the auger has been removed, the water seal will have to be replaced. Remove the water seal top half from the auger, and inspect the auger for minerals, clean as required.

Breaker and

Auger Assembly

WARNING!

 

The auger has

 

sharp edges,

Slide Hammer Puller

handle with care.

Thread into the Auger Here

Page 35

Image 41
Contents By Ice-O-Matic Pearl Ice SeriesPage Keep this manual for future reference IntroductionTable Of Contents Inspect Promptly Freight Claim ProcedureVisible Loss or Damage Concealed Loss or DamageGoverning LAW WarrantyFor the Installer GEM0650/0956R GEM1256R Bin Application Ice Machine SpecificationsStorage Bin LocationIce machine Water LimitationsRemote Condenser ERC Dimensions Inches GRC1001 GRC1061 GCR2061Pearl Ice Number Line SetsCalculation Example Remote Condenser LocationCalculation Formula Precharged Line Set Routing Remote Condenser LocationRoof Attachment Typical Installation Final Connections Coupling Instructions Initial ConnectionsDrains Ice Machine For the PlumberWater Inlet For the Electrician Completed Installation Final Check List Start Up There are no adjustments to make, so replace the panelsPre-Start Inspection Start UpComponent Description Control Board GEM0650/0956/1256 Remote Electrical Sequence Water Operation WaterWater Level Water SystemOperation Refrigeration Refrigeration SchematicLow Condensing Temperature Pump Down Operation Performance Sanitizing and Cleaning Brush in direction of fins Condenser MaintenanceBearing Maintenance Bearing MaintenanceWater Sensor Sensor MaintenanceBin Control Sensor Auger Auger MaintenanceSymptom Possible Cause Probable Correction Service DiagnosisSymptom High pressure cut out check Control System DiagnosticsBin Controls Ice Level Sensors Water Reservoir, Bin ControlWater Reservoir Bearing and Breaker To Remove the Breaker Bearing AssemblyTo Remove the Auger AugerTo Remove the Water Seal Water SealRemoval of the Water Seal To Replace the Water Seal Replacing the Water SealTo Reassemble the Evaporator and Auger EvaporatorTo Replace the Evaporator Gear Motor To Remove and Repair the Gear Motor AssemblyTo Check the Gear Motor To Inspect the Gear MotorFan Blade and Motor To Remove the Condenser Fan Motor AssemblyCharging Procedure Refrigeration ServiceWiring Diagram GEM0650R GEM0650R Wiring DiagramWiring Diagram GEM0956R GEM0956R Wiring DiagramWiring Diagram GEM1256R GEM1256R Wiring DiagramWhat to Do Before Calling for Service Service History