Jackson technical manual AJ-44 Steam Left to, Right

Page 17

 

Issued: 03-

AJ-44C Series

9

21-2006 Revised: 09-29-2007

Technical Manual 7610-001-76

 

 

-22

 

Recommended Table Fabrication

Note: Tub Will Accept

 

Rack Rail

a Table Flange

Left to Right

Table

Up to 24 7/8"

(632 mm)

 

Legend

 

Rack Rail Height

 

 

Use Silicone Sealer

 

3/4" (19 mm)

 

 

 

 

 

 

 

A - Machine water inlet 3/4" NPT 180°F

 

 

 

Between Table and

 

Table Turndown

21" (533 mm)

 

 

 

 

Hi-temp,140°F Low-temp minimum

 

Above Dishtable

 

Tub

Lip of Machine to

 

Flange 3/4" Max

 

 

 

 

 

 

B - Electrical connection

1/4" (6mm) - 5/16" (8mm)

 

Prevent Leakage

 

 

 

 

 

 

 

 

 

C - Drain connection 1-1/2" NPT

 

 

 

 

14 [355mm]

 

 

 

 

4 1/2 [114mm]

 

 

 

 

 

 

D - Vent collar - Optional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

 

 

 

 

 

 

 

 

 

 

 

 

E - Vent cowl standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F - 3/4" NPT Steam connection

 

 

 

 

 

 

 

 

 

 

 

 

 

38 [966mm]

M

 

 

G - 3/4" NPT Condensate return

 

 

 

 

 

 

 

 

 

 

 

K

 

1141 [285mm]

61

[159mm]

H - Steam electrical connection

 

 

 

 

 

 

 

 

 

 

 

 

 

H

4

 

 

J - 1" NPT Steam connection

 

 

 

 

 

 

 

 

B

 

 

F

 

 

 

 

 

 

 

 

21 [535mm]

 

 

 

 

 

 

 

 

 

 

885 [218mm]

K - 3/4" Condensate connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L - 3/4" NPT Incoming 110°F water

 

25 [637mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M - 3/4" NPT 180°F water to dishmachine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: All vertical dimensions are +/- 1/2"

 

 

 

8 [204mm]

 

 

 

44 [1118mm]

 

 

 

L

5

J

 

578 [148mm]

 

 

 

 

 

 

 

 

 

 

 

from floor due to adjustable bullet feet.

 

 

 

 

Scrap

 

 

 

Table to Table

 

 

 

 

138

[345mm]

43

[110mm]

 

 

 

 

 

 

Trough

 

 

 

52 [1321mm]

 

 

 

 

233

[604mm]

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

4" (102 mm) wide x 16" (406 mm)

 

 

60 [1524mm]

 

Floor Sink Or Drain

 

 

 

 

 

 

 

long cutout in Vent Cowl/Splash

 

 

 

With 3" (76 mm)

 

 

 

 

 

 

 

 

 

Overall

 

 

 

 

 

84 [2134mm]

 

Shield. Shipped with Cover Plate.

 

 

 

 

 

Minimum Drain Line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With Doors Open

 

 

135

[346mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 [635mm]

 

 

A

751

 

8

 

 

1821 [467mm]

 

 

 

 

 

 

 

 

 

[1919mm]

 

 

 

 

 

 

 

 

21 [533mm]

 

 

 

2

 

 

 

 

 

 

 

B

 

8 [204mm]

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

B

 

 

 

12 [307mm]

 

1 [25mm]

 

 

4 [102mm]

 

 

 

 

 

 

 

 

 

 

 

 

621

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1590mm]

 

 

 

 

 

7 [178mm]

 

 

 

 

 

 

 

665

[1692mm]

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

10" High

 

 

 

 

 

D

 

 

 

 

 

 

 

6521 [1665mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Backsplash

 

 

 

 

 

 

 

 

 

25 [635mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dish Clearance

 

 

 

 

21 [15mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear of

 

 

 

 

 

14 [356mm]

 

 

 

 

43 [1092mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

Machine

 

 

 

 

 

Minimum

 

 

 

 

H

 

J

 

 

 

 

 

Drive

 

 

 

Scrap

 

1

[316mm]

 

F

 

 

M

 

 

 

34 [864mm]

 

 

 

 

Trough

 

 

 

 

 

 

 

 

Unit

 

 

 

Drive

122

 

 

 

 

 

 

 

 

 

601 [1530mm]

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

171

[445mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29 [737mm]

 

10 [254mm]

6 [152mm]

 

 

 

683 [162mm]

 

C

 

721 [190mm]

 

Left Side

 

10 [254mm]

 

7 [178mm]

 

 

 

 

 

 

1185 [295mm]

 

 

 

81 [218mm]

 

 

 

 

 

 

 

Front View

 

 

 

 

153

[400mm]

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

4

3

 

Right Side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

168 [417mm]

 

AJ-44 STEAM - LEFT TO

SECTION 1: SPECIFICATION

RIGHT

INFORMATION

Image 17
Contents AJ-66CEL For Jackson ModelsAJ-44CGP AJ-66CGP AJ-66CSLONE Year Limited Parts & Labor Warranty Manufacturers WarrantyStop Pare Arret Revision Made Applicable Details Date ECN Nomenclature for the Models Covered in this Manual AJ-44CSLTable of Contents D226 Steam Booster Section Parts Parts SectionSide Loader Section Viii Maintenance & Repair Centers Electrical SchematicsSection Specification Information Specification Information AJ-66CE/CEL Models AJ-44CE/CEL ModelsAJ-44CGP Models AJ-66CGP ModelsD226 Steam Booster AJ-80CE/CEL ModelsAJ-80CS/CSL Models Left to Right Specification Information AJ-44 Electric Left to RightAJ-44 Right to LeftInformation to Right Left InformationAJ-44 GAS Right to Right AJ-44 Steam Left toSpecification Information AJ-44 Steam Right to Left Left to Right Specification Information AJ-66 Electric Left to RightRight to Left Specification Information AJ-66 Electric Right to LeftSpecification Information AJ-66 GAS Left to Right AJ-66 GAS Right to Left to RightAJ-66 Steam Left to Right to Left Specification Information AJ-66 Steam Right to LeftLeft to Right Specification Information AJ-80 Electric Right to Left Left to Right Specification Information AJ-80 GAS Left to RightAJ-80 GAS Right to Right to LeftRecommended Table Fabrication AJ-80 Steam Left toRight to Left Specification Information AJ-80 Steam Right to LeftSection A-A Side Loader Left to Right DimensionsSide Loader Right to Left Dimensions Side Loader Installed Dimensions D226 Steam Booster Dimensions D226 Steam Booster Plumbing Line Drawings Rear View Typical Electric and GAS Booster DimensionsSection Installation & Operation Instructions Installation Instructions INSTALLATION/OPERATION InstructionsIncoming Power Connection Detergent Connection Point Machine rear view Deliming Operations Changing the AJ-44CE/CS Direction of Travel PreparationINSTALLATION/OPERATION Instructions Removing the bracket nut INSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions Special Parts Please refer to the chart for placement of the curtains Side Loader Installation & Operation Instructions Plumbing Equipment MountingOperation Shutdown for Service onlyGAS Conveyor Hose Installation GAS Conveyor Hose InstallationDishmachine Operating Instructions Dishmachine Operation Instructions Drive Mechanism Maximum Speed Adjustment Changing Dual Sanitization ModeOrange background Detergent Control Installation Instructions Striker Plate Limit Switch Installation InstructionsSection Preventative Maintenance Preventative Maintenance Preventative MaintenanceMaintenance of the Water Pressure Regulator D226 MaintenanceSHC-90W Lubrication Chart for Drive GearLubrication & Maintenance Drive Motor Gear Reducer Preventative MaintenanceSection Troubleshooting Section Common Problems TroubleshootingItems Torque Spec Torque SettingsProblem Power light does not illuminate D226 Common Problems
Related manuals
Manual 8 pages 11.95 Kb