Jackson AJ-44 Changing Dual Sanitization Mode, Drive Mechanism Maximum Speed Adjustment

Page 56

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

CHANGING DUAL SANITIZATION MODE

If the machine has a dataplate like the one shown, which indi- cates both Hot Water Sanitizing and Chemical Sanitizing operation parameters (the area within dashed box), it is pos- sible to change the sanitizing mode after the machine has left the original manufacturer's facility. This change can only be performed by an authorized Jackson service technician. If the machine does not have a dataplate like the one shown, the sanitization mode CAN NOT be changed.

Follow the instructions below to change the mode of sanitiza- tion. Failure to follow these instructions can result in a viola- tion of applicable regulatory codes.

DRIVE MECHANISM MAXIMUM SPEED ADJUSTMENT:

Note: This adjustment is only required when changing from hot water sanitizing to chemical sanitizing mode.

Locate the maximum speed adjustment mechanism at the top of the conveyor drive mechanism (Figure 1). Figure 2 shows an enlarged view of the maximum speed adjustment mecha- nism. Loosen the Bottom Jam Nut approximately one turn counterclockwise. Move the Top Jam Nut down on the threaded shaft by turning it approximately 1/2 turn counter- clockwise. Tighten the Adjustment Nut by turning it clockwise. Retighten the Bottom Jam Nut against the Top Jam Nut.

Figure 1: Drive Mechanism

 

 

 

 

An

Company

 

MODEL:

XXXXXXXXX

 

SERIAL #

XXX XXXX X

 

 

 

 

60 HZ 3 PHASE 3 WIRE

 

 

 

 

208 V 230 V

460 V

WASH MOTOR

2.0 HP

5.6 A

5.6 A

2.8 A

DRIVE MOTOR

1/4 HP

1.1 A

1.1 A

0.6 A

WASH HEATER LOAD

15 KW

41.7 A

37.7 A

18.8 A

TOTAL AMP LOAD

 

 

48.4 A

44.4 A

22.2 A

HOT WATER

 

CHEMICAL

SANITIZING

 

SANITIZING

6.9 FPM

CONVEYOR SPEED

6.5 FPM

160° F MIN.

WASH TANK TEMPERATURE

140° F MIN.

180° F MIN.

FINAL RINSE TEMPERATURE

140° F MIN.

20 ±5 PSI

FLOW PRESSURE

20 ±5 PSI

NOTE: SEE INSTRUCTION IN MANUAL FOR MODIFYING MODE OF

SANITIZATION.

 

 

US Patent Number(s):

 

6,012,567

Commercial

 

Canadian Patent Number(s):

Dishwasher

2,205,331

597G

 

Made in the USA

 

 

 

 

Jackson MSC Inc.

 

 

P. O. Box 1060

 

 

 

 

Barbourville, KY. 40906

 

 

(606) 523-9795

 

 

09905-021-70-81 E

 

 

 

Please note the parameters for both modes of sanitization. If your data plate has this information, it is convertible from one mode to another.

Adjustment Nut

Top Jam Nut

Bottom Jam Nut

Figure 2

AJ-44C Series Technical Manual 7610-001-76-22

Issued: 03-21-2006 Revised: 05-03-2007

48

Image 56
Contents For Jackson Models AJ-66CELAJ-44CGP AJ-66CGP AJ-66CSLManufacturers Warranty ONE Year Limited Parts & Labor WarrantyStop Pare Arret Revision Made Applicable Details Date ECN AJ-44CSL Nomenclature for the Models Covered in this ManualTable of Contents D226 Steam Booster Section Parts Parts SectionSide Loader Section Electrical Schematics Viii Maintenance & Repair CentersSection Specification Information Specification Information AJ-44CE/CEL Models AJ-66CE/CEL ModelsAJ-44CGP Models AJ-66CGP ModelsD226 Steam Booster AJ-80CE/CEL ModelsAJ-80CS/CSL Models Specification Information AJ-44 Electric Left to Right Left to RightRight to Left AJ-44Information to Right Left InformationAJ-44 GAS Right to AJ-44 Steam Left to RightSpecification Information AJ-44 Steam Right to Left Specification Information AJ-66 Electric Left to Right Left to RightSpecification Information AJ-66 Electric Right to Left Right to LeftSpecification Information AJ-66 GAS Left to Right Left to Right AJ-66 GAS Right toAJ-66 Steam Left to Specification Information AJ-66 Steam Right to Left Right to LeftLeft to Right Specification Information AJ-80 Electric Right to Left Specification Information AJ-80 GAS Left to Right Left to RightRight to Left AJ-80 GAS Right toAJ-80 Steam Left to Recommended Table FabricationSpecification Information AJ-80 Steam Right to Left Right to LeftSide Loader Left to Right Dimensions Section A-ASide Loader Right to Left Dimensions Side Loader Installed Dimensions D226 Steam Booster Dimensions D226 Steam Booster Plumbing Line Drawings Typical Electric and GAS Booster Dimensions Rear ViewSection Installation & Operation Instructions INSTALLATION/OPERATION Instructions Installation InstructionsIncoming Power Connection Detergent Connection Point Machine rear view Deliming Operations Preparation Changing the AJ-44CE/CS Direction of TravelINSTALLATION/OPERATION Instructions Removing the bracket nut INSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions Special Parts Please refer to the chart for placement of the curtains Side Loader Installation & Operation Instructions Equipment Mounting PlumbingShutdown for Service only OperationGAS Conveyor Hose Installation Conveyor Hose Installation GASDishmachine Operating Instructions Dishmachine Operation Instructions Changing Dual Sanitization Mode Drive Mechanism Maximum Speed AdjustmentOrange background Detergent Control Striker Plate Limit Switch Installation Instructions Installation InstructionsSection Preventative Maintenance Preventative Maintenance Preventative MaintenanceD226 Maintenance Maintenance of the Water Pressure RegulatorLubrication Chart for Drive Gear SHC-90WDrive Motor Gear Reducer Preventative Maintenance Lubrication & MaintenanceSection Troubleshooting Section Troubleshooting Common ProblemsTorque Settings Items Torque SpecD226 Common Problems Problem Power light does not illuminate
Related manuals
Manual 8 pages 11.95 Kb