Jackson AJ-44 technical manual Lubrication Chart for Drive Gear, SHC-90W

Page 63

SECTION 3: PREVENTATIVE MAINTENANCE

LUBRICATION CHART FOR DRIVE GEAR

Note: The maintenance procedures detailed here are manufacturer’s instructions for the WINSMITH brand of gear reducer that is installed on the rack conveyors covered in this manual.

Ambient Temperature

-30 - 15°F

16 - 50°F

51 - 95°F

51 - 95°F

96 - 131°F

96 - 131°F

Final Stage Worm Speed1

up to 2000 FPM

up to 2000 FPM

up to 450 FPM

above 450 FPM

up to 450 FPM

above 450 FPM

ISO Viscosity Grade

220

460

680

460

680

4601

AGMA Lubricant No.

5S

#7 Compounded

#8 Compounded

#7 Compounded

8S

7S

Mobil

SHC 630

600W Super

Extra Hecla Super

600W Super

SHC 636

SHC 634

 

 

Cylinder

 

Cylinder

 

 

American Lubricants

SHC-90W

AGMA #7 Gear Oil

AGMA #8 Gear Oil

AGMA #7 Gear Oil

N/A

N/A

Castrol

Tribol 800/220

Tribol 1105-7C

Tribol 1105-8C

Tribol 1105-7C

Tribol 800/680

Tribol 800/460

Chevron

Tegra 220

Cylinder Oil W460

Cylinder Oil W680

Cylinder Oil W460

Tegra 680

Tegra 460

Conoco

Syncon R & O

Inca Oil 460

Inca Oil 680

Inca Oil 460

N/A

Syncon R & O

 

220

 

 

 

 

460

Exxon (Esso)

Teresstic SHP220

Spartan EP 460

Spartan EP 680

Spartan EP 460

Teresstic SHP 680

Teresstic SHP

 

 

 

 

 

 

460

Fiske Brothers

SPO-MG

SPO-277

SPO-288

SPO-277

N/A

N/A

Shell

Omala RL 220

Valvata J 460

Valvata J 680

Valvata J 460

Omala RL 680

Omala RL 460

Texaco

Pinnacle 220

Vanguard 460

Vanguard 680

Vanguard 460

Pinnacle 680

Pinnacle 460

(1)The sliding velocity in feet per minute (FPM) for standard ratios is determined by multiplying the speed of the worm in RPM by the factor from the table below. For selecting proper lubricant, use the speed of the worm in the final stage (input RPM divided by the first stage ratio).

AJ-44C Series Technical Manual 7610-001-76-22

Issued: 03-21-2006 Revised: N/A

55

Image 63
Contents AJ-66CSL For Jackson ModelsAJ-66CEL AJ-44CGP AJ-66CGPONE Year Limited Parts & Labor Warranty Manufacturers WarrantyStop Pare Arret Revision Made Applicable Details Date ECN Nomenclature for the Models Covered in this Manual AJ-44CSLTable of Contents Parts Parts Section Side Loader SectionD226 Steam Booster Section Viii Maintenance & Repair Centers Electrical SchematicsSection Specification Information Specification Information AJ-66CGP Models AJ-44CE/CEL ModelsAJ-66CE/CEL Models AJ-44CGP ModelsAJ-80CE/CEL Models AJ-80CS/CSL ModelsD226 Steam Booster Left to Right Specification Information AJ-44 Electric Left to RightAJ-44 Right to LeftInformation to Right Information AJ-44 GAS Right toLeft Right AJ-44 Steam Left toSpecification Information AJ-44 Steam Right to Left Left to Right Specification Information AJ-66 Electric Left to RightRight to Left Specification Information AJ-66 Electric Right to LeftSpecification Information AJ-66 GAS Left to Right AJ-66 GAS Right to Left to RightAJ-66 Steam Left to Right to Left Specification Information AJ-66 Steam Right to LeftLeft to Right Specification Information AJ-80 Electric Right to Left Left to Right Specification Information AJ-80 GAS Left to RightAJ-80 GAS Right to Right to LeftRecommended Table Fabrication AJ-80 Steam Left toRight to Left Specification Information AJ-80 Steam Right to LeftSection A-A Side Loader Left to Right DimensionsSide Loader Right to Left Dimensions Side Loader Installed Dimensions D226 Steam Booster Dimensions D226 Steam Booster Plumbing Line Drawings Rear View Typical Electric and GAS Booster DimensionsSection Installation & Operation Instructions Installation Instructions INSTALLATION/OPERATION InstructionsIncoming Power Connection Detergent Connection Point Machine rear view Deliming Operations Changing the AJ-44CE/CS Direction of Travel PreparationINSTALLATION/OPERATION Instructions Removing the bracket nut INSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions Special Parts Please refer to the chart for placement of the curtains Side Loader Installation & Operation Instructions Plumbing Equipment MountingOperation Shutdown for Service onlyGAS Conveyor Hose Installation GAS Conveyor Hose InstallationDishmachine Operating Instructions Dishmachine Operation Instructions Drive Mechanism Maximum Speed Adjustment Changing Dual Sanitization ModeOrange background Detergent Control Installation Instructions Striker Plate Limit Switch Installation InstructionsSection Preventative Maintenance Preventative Maintenance Preventative MaintenanceMaintenance of the Water Pressure Regulator D226 MaintenanceSHC-90W Lubrication Chart for Drive GearLubrication & Maintenance Drive Motor Gear Reducer Preventative MaintenanceSection Troubleshooting Section Common Problems TroubleshootingItems Torque Spec Torque SettingsProblem Power light does not illuminate D226 Common Problems