Jackson AJ-44 technical manual Striker Plate Limit Switch Installation Instructions

Page 59

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

STRIKER PLATE LIMIT SWITCH INSTALLATION INSTRUCTIONS

Installation Instructions:

1.Wiring: The switch is wired common and nor- mally open because of the hinge design. By interrupting the line in series with the door switches, the dishmachine ceases to operate. Refer to the machine schematic for details on how to wire the switch.

1/3 RACK WIDTH

2.Parts of the table switch are mounted in the dishtable, at the end of the table and under the table. See the drawing(s) for the relationship of the switch to the table.

3.Move the limit switch as far down on the two slots as possible and see that the limit switch is straight on the base plate. This might require adjustment of the nut on the connector for the limit switch.

4.Then adjust the inside and the outside con- nector nuts for the connector box so that it lines up even with the limit switch and the base plate.

5.Tighten down the nuts for the seal so that they are tight.

TABLE LIMIT SWITCH THROUGH ROD HOLES

TABLE

SWITCH RODS

STRIKE PLATE

STRIKE PLATE BOLTS

INSTALL AT FAR END OF TABLE

6.If you have any difficulty you might have to adjust the connectors to the seal, screwing in or screwing out until the installation is straight on the table and the limit switch is actuated correctly by the rack.

MOUNTING BOLTS

TABLE BOTTOM

Ø0.75 Ø0.25

Unless noted, all dimensions are in inches.

3.00

2.00

1.875

1.50

TABLE BOTTOM

AJ-44C Series Technical Manual 7610-001-76-22

Issued: 03-21-2006 Revised: N/A

51

Image 59
Contents AJ-66CSL For Jackson ModelsAJ-66CEL AJ-44CGP AJ-66CGPONE Year Limited Parts & Labor Warranty Manufacturers WarrantyStop Pare Arret Revision Made Applicable Details Date ECN Nomenclature for the Models Covered in this Manual AJ-44CSLTable of Contents D226 Steam Booster Section Parts Parts SectionSide Loader Section Viii Maintenance & Repair Centers Electrical SchematicsSection Specification Information Specification Information AJ-66CGP Models AJ-44CE/CEL ModelsAJ-66CE/CEL Models AJ-44CGP ModelsD226 Steam Booster AJ-80CE/CEL ModelsAJ-80CS/CSL Models Left to Right Specification Information AJ-44 Electric Left to RightAJ-44 Right to LeftInformation to Right Left InformationAJ-44 GAS Right to Right AJ-44 Steam Left toSpecification Information AJ-44 Steam Right to Left Left to Right Specification Information AJ-66 Electric Left to RightRight to Left Specification Information AJ-66 Electric Right to LeftSpecification Information AJ-66 GAS Left to Right AJ-66 GAS Right to Left to RightAJ-66 Steam Left to Right to Left Specification Information AJ-66 Steam Right to LeftLeft to Right Specification Information AJ-80 Electric Right to Left Left to Right Specification Information AJ-80 GAS Left to RightAJ-80 GAS Right to Right to LeftRecommended Table Fabrication AJ-80 Steam Left toRight to Left Specification Information AJ-80 Steam Right to LeftSection A-A Side Loader Left to Right DimensionsSide Loader Right to Left Dimensions Side Loader Installed Dimensions D226 Steam Booster Dimensions D226 Steam Booster Plumbing Line Drawings Rear View Typical Electric and GAS Booster DimensionsSection Installation & Operation Instructions Installation Instructions INSTALLATION/OPERATION InstructionsIncoming Power Connection Detergent Connection Point Machine rear view Deliming Operations Changing the AJ-44CE/CS Direction of Travel PreparationINSTALLATION/OPERATION Instructions Removing the bracket nut INSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions Special Parts Please refer to the chart for placement of the curtains Side Loader Installation & Operation Instructions Plumbing Equipment MountingOperation Shutdown for Service onlyGAS Conveyor Hose Installation GAS Conveyor Hose InstallationDishmachine Operating Instructions Dishmachine Operation Instructions Drive Mechanism Maximum Speed Adjustment Changing Dual Sanitization ModeOrange background Detergent Control Installation Instructions Striker Plate Limit Switch Installation InstructionsSection Preventative Maintenance Preventative Maintenance Preventative MaintenanceMaintenance of the Water Pressure Regulator D226 MaintenanceSHC-90W Lubrication Chart for Drive GearLubrication & Maintenance Drive Motor Gear Reducer Preventative MaintenanceSection Troubleshooting Section Common Problems TroubleshootingItems Torque Spec Torque SettingsProblem Power light does not illuminate D226 Common Problems
Related manuals
Manual 8 pages 11.95 Kb