RINSE REGULATING THERMOSTAT REPLACEMENT

12.Once both wires are attached, ensure that there is no excess hanging out where it could become pinched by any cover or such.

13.Replace the heater nuts (if removed) and torque down as required per the technical manual. Different models may have different torque specifications. Contact Jackson Technical Service if there are any questions regarding this.

AFTER MAINTENANCE ACTIONS

Jackson MSC Inc. provides technical support for all of the dishmachines detailed in this manual. We strongly rec- ommend that you refer to this manual before making a call to our technical support staff. Please have this manual with you when you call so that our staff can refer you, if necessary, to the proper page. Technical support is available from 8:00 a.m. to 5:00 p.m. (EST), Monday through Friday. Technical support is not available on holidays. Contact technical support toll free at 1-888-800-5672. Please remember that technical support is available for service personnel only.

Calibrating the new thermostat.

Once the new thermostat is installed, it will be nece- sary to ensure that it operates at the required and appropriate ranges. The new thermostat has an adjustment that can be turned using a small flathead screwdriver. Several cycles will need to be run on the unit while observing the final rinse tem- perature. The thermostat needs to cycle so that the final rinse water meets the indicated minimums on the machine data plate for every cycle.

SPECIAL NOTES

Work performed on Jackson dishmachines by unau- thorized or unqualified personnel may void the warranty. Before beginning this or any other maintenance evolution on a unit under warranty, you should contact a certified Jackson technician or Jackson Technical Service. You can find a list of qualified service agencies in the back of you unit’s installation manual.

SPECIAL PARTS

Thermostat Replacement Kit: 06401-003-13-94*

*The kit contains a thermostat, imperial brass fitting, jumper wires and instructions.

CONTACT INFORMATION

200 Series Technical Manual

7610-100-45-00 Rev. E (02/10/2006)

26

Image 31
Contents Steam Heated Models Technical ManualPage Revision Made Applicable Details Date ECN Nomenclature for the Models Covered in this Manual 200 NBDRAWING/PARTS Section Table of Contents Section Description SpecificationsII. INSTALLATION/OPERATION Instructions VII Electrical DiagramsSection Specification Information Wash Pump Capacity TemperaturesOperating Cycle Seconds Tank Capacity GallonsFront View Specification Information DimensionsTOP View Corner Conversion TOP View FrontTable Dimensions Specification InformationSection INSTALLATION/OPERATION Instructions Raise Lower Frame with Adjustable Foot GND INSTALLATION/OPERATION Instructions Detergent Control INSTALLATION/OPERATION Instructions Operation Instructions INSTALLATION/OPERATION Instructions Operation Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Section Problem Dishmachine will not run. No power to the unit Troubleshooting Section Common ProblemsProblem Water temperature is less than required Section Service Procedures Tools Required Service Procedures Rinse Solenoid Valve Repair Parts KITSteps PreparationPrying open the coil wire cover Removing the valve bonnet Special Parts After Maintenance ActionsSet the cap to the side Service Procedures Vacuum Breaker Repair Parts KITRemoving the plunger Service Procedures Rinse Regulating Thermostat Replacement Service Procedures Rinse Regulating Thermostat Replacement Tightening the brass fitting Contact Information Special NotesSection Parts Section Jackson Parts Section Control BOX AssemblyQTY Description Parts Section Hood Assembly Single Piece Weldment Parts Section Cantilever ARM/DOOR Assemblies Parts Section See page Entitled Wash HEATERS/RINSE Heaters Parts Section TUB AssemblyTub Weldment Not used on 200S Parts Section Rinse Tank Assembly 200B Rinse Heater 12 KW Parts Section Wash HEATERS/RINSE HeatersModel Volts Phase Wash Motor Assembly Parts Section Motor AssemblyParts Section Frame Assembly Parts Section Incoming Fill PLUMBING/OUTLET Plumbing Water Pressure Regulator KIT Wprk Option Plumbing Complete Vacuum Breaker Assembly Parts Section Coil Assembly 200S Parts Section Incoming Steam Plumbing Assembly 200S Parts Section Wash & Rinse ARM/MANIFOLD Assemblies Exploded View of Wash & Rinse Spindle Assembly Parts Section Safety Door Interlock SDI Option Parts Section Exhaust FAN Control Option FAN Load on Timer OutputFalse panel positioned in unit Parts Section False Panel InstallationSection Electrical Schematics 200/200B/200LT 208-230-460V, 50/60 HZ, Single & Three Phase Electricalschematics200S 208-230-460V, 50/60 HZ, Single & Three Phase