SECTION 6: PARTS SECTION
INCOMING FILL PLUMBING/OUTLET PLUMBING
200B INCOMING FILL PLUMBING | 200B OUTLET PLUMBING |
12
7
7
9
6
10
5
8
8
7
200/200LT INCOMING FILL PLUMBING
2
11
12
3
15
4
1
5
When servicing plumbing components, take care not to |
| |
damage the threads of each individual item. Damaged |
| |
threads can cause leaks and loss of pressure, which |
| |
16 could adversely effect the performance of the Tempstar | 13 | |
dishmachine. It is strongly recommended that teflon | ||
| ||
thread tape, used in conservative amounts, be applied | 14 | |
to threads when joining components together. It is not | ||
| ||
advised to use thread sealing compounds, sometimes |
| |
referred to as “pipe dope”. Compounds can be ejected |
| |
from the threads during the tightening process and |
| |
become lodged in key components, thereby rendering |
| |
them useless. Some of the components include the |
| |
solenoid valve and the pressure gauge isolation ball |
| |
valve. |
|
200 Series Technical Manual
39