Jackson 200S, 200LT, 200B technical manual After Maintenance Actions, Special Parts

Page 25

SECTION 5: SERVICE PROCEDURES

RINSE SOLENOID VALVE REPAIR PARTS KIT (CONTINUED)

Removing the screen retainer

19.Using the small flathead screwdriver, lift out the screen retainer. Verify that the holes in it are free of clogs and debris.

21.With the mesh screen removed, look down into the valve and verify it is not clogged. Remove any foreign objects from the valve body that would obstruct flow.

22.Reassemble the valve, reversing the steps needed to take it apart. Replace defective replacement parts with new parts from ordered kits. Ensure that components are sufficiently tightened to prevent leakage.

AFTER MAINTENANCE ACTIONS

Reconnect the incoming water (if disconnected) and turn on. Then restore power to the unit. Run the unit for at least 10 minutes to ensure there are no leaks. If any problems arise please contact your Jackson representative.

SPECIAL PARTS

Solenoid Valve Plunger Kit Includes plunger and spring Part number 06410-003-07-40

Solenoid Valve Diaphragm Kit Includes diaphragm and o-ring

Part number 06401-003-07-42 (3/4” NPT) Solenoid Valve 24 Volt Coil and Housing

Part number 04810-100-06-18 Complete Solenoid Valve

Part number 04810-100-01-40 (3/4”, 24 Volt)

Removing the mesh strainer screen

20.Again using the small flathead screwdriver, carefully remove the mesh screen from inside the valve body. The screen should be taken and rinsed out to remove any debris fouling it.

View inside the solenoid valve body

200 Series Technical Manual

7610-100-45-00 Rev. E (02/10/2006)

20

Image 25
Contents Steam Heated Models Technical ManualPage Revision Made Applicable Details Date ECN Nomenclature for the Models Covered in this Manual 200 NBII. INSTALLATION/OPERATION Instructions Table of Contents Section Description SpecificationsVII Electrical Diagrams DRAWING/PARTS SectionSection Specification Information Operating Cycle Seconds TemperaturesTank Capacity Gallons Wash Pump CapacityTOP View Specification Information DimensionsCorner Conversion TOP View Front Front ViewTable Dimensions Specification InformationSection INSTALLATION/OPERATION Instructions Raise Lower Frame with Adjustable Foot GND INSTALLATION/OPERATION Instructions Detergent Control INSTALLATION/OPERATION Instructions Operation Instructions INSTALLATION/OPERATION Instructions Operation Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Section Problem Dishmachine will not run. No power to the unit Troubleshooting Section Common ProblemsProblem Water temperature is less than required Section Service Procedures Steps Service Procedures Rinse Solenoid Valve Repair Parts KITPreparation Tools RequiredPrying open the coil wire cover Removing the valve bonnet Special Parts After Maintenance ActionsSet the cap to the side Service Procedures Vacuum Breaker Repair Parts KITRemoving the plunger Service Procedures Rinse Regulating Thermostat Replacement Service Procedures Rinse Regulating Thermostat Replacement Tightening the brass fitting Contact Information Special NotesSection Parts Section Jackson Parts Section Control BOX AssemblyQTY Description Parts Section Hood Assembly Single Piece Weldment Parts Section Cantilever ARM/DOOR Assemblies Parts Section See page Entitled Wash HEATERS/RINSE Heaters Parts Section TUB AssemblyTub Weldment Not used on 200S Parts Section Rinse Tank Assembly 200B Rinse Heater 12 KW Parts Section Wash HEATERS/RINSE HeatersModel Volts Phase Wash Motor Assembly Parts Section Motor AssemblyParts Section Frame Assembly Parts Section Incoming Fill PLUMBING/OUTLET Plumbing Water Pressure Regulator KIT Wprk Option Plumbing Complete Vacuum Breaker Assembly Parts Section Coil Assembly 200S Parts Section Incoming Steam Plumbing Assembly 200S Parts Section Wash & Rinse ARM/MANIFOLD Assemblies Exploded View of Wash & Rinse Spindle Assembly Parts Section Safety Door Interlock SDI Option Parts Section Exhaust FAN Control Option FAN Load on Timer OutputFalse panel positioned in unit Parts Section False Panel InstallationSection Electrical Schematics 200/200B/200LT 208-230-460V, 50/60 HZ, Single & Three Phase Electricalschematics200S 208-230-460V, 50/60 HZ, Single & Three Phase