Jackson 200S, 200LT, 200B Service Procedures Rinse Regulating Thermostat Replacement

Page 28

SECTION 5: SERVICE PROCEDURES

RINSE REGULATING THERMOSTAT REPLACEMENT

Many dishmachines comes with integral booster tanks to ensure proper temperature of the final rinse. Jackson has predominantly used two manufacturers of thermostats, EGO and Stemco. These instructions are for use with kit 06401-003-13-94, which is to replace an EGO rinse regulating thermostat with a Stemco brand.

Jackson offers all of the repair parts necessary for performing this task.

The instructions provided here are for maintenance personnel only. Unauthorized persons should not attempt any of the steps contained in these instructions.

Warning: many of the instructions and steps within this document require the use of tools. Only autho- rized personnel should ever perform any maintenance procedure on the dishmachine!

PREPARATION

1.Power must be secured to the unit at the service breaker. Tag or lock out the service breaker to prevent acci- dental or unauthorized energizing of the machine.

2.Ensure that incoming water to the machine is secured either by use of a shut-off valve or disconnecting the incoming water line.

3.The unit must be drained completely with the drain stopper removed (if applicable).

4.Remove any and all access covers.

TOOLS REQUIRED

The following tools may be needed to perform this maintenance evolution:

1.3/8” Nutdriver

2.7/16” Combination Wrench

3.Needlenose Pliers

4.Phillipshead Screwdriver

5.Flathead Screwdriver

6.Ratchet with 1/2” Socket

TIME REQUIRED

It is estimated that it will take (1) person sixty minutes to perform this task, not including all of the items indicated in the section entitled “PREPARATION”.

IMPORTANT NOTES

1.Read these instructions thoroughly before attempting this maintenance task. Become familiar with the parts and what actions need to be taken. This will save time in the long run!

2.These instructions are shown using a Tempstar model dishmachine. However the steps provided should work for models such as the 200B as well.

STEPS

1.Some models, such as the Tempstar pictured below, will require that the thermostat bracket removed from the heater. Using a ratchet, extension and 1/2” socket, remove the nuts and lock washer holding the bracket on.

Removing the thermostat bracket/heater nuts.

2.With the thermostat and thermostat bracket safely out of the way, use a 7/16” combination wrench to loosen and then remove the imperial brass fitting holding the probe in.

3.Remove the wires from the old thermostat. It may be nec- essary to use the needlenose pliers to accomplish this.

4.Remove the thermostat bracket mounting nuts with the 7/16” nutdriver.

Removing the thermostat bracket.

200 Series Technical Manual 7610-100-45-00 Rev. E (02/10/2006)

23

Image 28
Contents Technical Manual Steam Heated ModelsPage Revision Made Applicable Details Date ECN 200 NB Nomenclature for the Models Covered in this ManualTable of Contents Section Description Specifications II. INSTALLATION/OPERATION InstructionsVII Electrical Diagrams DRAWING/PARTS SectionSection Specification Information Temperatures Operating Cycle SecondsTank Capacity Gallons Wash Pump CapacitySpecification Information Dimensions TOP ViewCorner Conversion TOP View Front Front ViewSpecification Information Table DimensionsSection INSTALLATION/OPERATION Instructions Raise Lower Frame with Adjustable Foot GND INSTALLATION/OPERATION Instructions Detergent Control INSTALLATION/OPERATION Instructions Operation Instructions INSTALLATION/OPERATION Instructions Operation Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Section Troubleshooting Section Common Problems Problem Dishmachine will not run. No power to the unitProblem Water temperature is less than required Section Service Procedures Service Procedures Rinse Solenoid Valve Repair Parts KIT StepsPreparation Tools RequiredPrying open the coil wire cover Removing the valve bonnet After Maintenance Actions Special PartsService Procedures Vacuum Breaker Repair Parts KIT Set the cap to the sideRemoving the plunger Service Procedures Rinse Regulating Thermostat Replacement Service Procedures Rinse Regulating Thermostat Replacement Tightening the brass fitting Special Notes Contact InformationSection Parts Section Parts Section Control BOX Assembly JacksonQTY Description Parts Section Hood Assembly Single Piece Weldment Parts Section Cantilever ARM/DOOR Assemblies Parts Section Parts Section TUB Assembly See page Entitled Wash HEATERS/RINSE HeatersTub Weldment Not used on 200S Parts Section Rinse Tank Assembly 200B Parts Section Wash HEATERS/RINSE Heaters Rinse Heater 12 KWParts Section Motor Assembly Model Volts Phase Wash Motor AssemblyParts Section Frame Assembly Parts Section Incoming Fill PLUMBING/OUTLET Plumbing Water Pressure Regulator KIT Wprk Option Plumbing Complete Vacuum Breaker Assembly Parts Section Coil Assembly 200S Parts Section Incoming Steam Plumbing Assembly 200S Parts Section Wash & Rinse ARM/MANIFOLD Assemblies Exploded View of Wash & Rinse Spindle Assembly Parts Section Safety Door Interlock SDI Option FAN Load on Timer Output Parts Section Exhaust FAN Control OptionParts Section False Panel Installation False panel positioned in unitSection Electrical Schematics Electricalschematics 200/200B/200LT 208-230-460V, 50/60 HZ, Single & Three Phase200S 208-230-460V, 50/60 HZ, Single & Three Phase