SECTION 1: SPECIFICATION INFORMATION
OPERATING CAPACITIES |
|
|
|
|
|
|
|
|
| |
PERFORMANCE/CAPABILITIES |
| ELECTRICAL REQUIREMENTS |
|
|
| |||||
|
|
|
|
| ||||||
OPERATING CAPACITY (RACKS/HOUR) |
| WASH PUMP MOTOR HP |
|
|
| 1 | ||||
RACKS PER HOUR | 57 |
|
|
| ||||||
|
|
|
|
|
|
|
| |||
DISHES PER HOUR | 1425 | NOTE: Typical Electrical Circuit is based upon (1) 125% of | ||||||||
GLASSES PER HOUR | 1425 | the full amperage load of the machine and (2) typical fixed- | ||||||||
|
| trip circuit breaker sizes as listed in the NEC 2002 Edition. | ||||||||
OPERATING CYCLE (SECONDS) |
| Local codes may require more stringent protection than | ||||||||
|
| what is displayed here. Always verify with your electrical | ||||||||
WASH TIME | 45 | service contractor that your circuit protection is adequate | ||||||||
RINSE TIME | 11 | and meets all applicable national and local codes. These | ||||||||
TOTAL CYCLE | 58 | numbers are provided in this manual simply for reference | ||||||||
TANK CAPACITY (GALLONS) |
| and may change without notice at any given time. | ||||||||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| RINSE |
|
| TYPICAL | |
WASH TANK (MINIMUM) | 8.0 | MODEL | VOLTS PH | HZ | HEATER | TOTAL | ELECTRICAL | |||
BOOSTER TANK | 3.0 | RATINGS | AMPS | CIRCUIT | ||||||
200B | 208 | 1 | 60 | 12KW@230 | 72 A | 90 AMP | ||||
|
| |||||||||
WASH PUMP CAPACITY |
| 200B | 230 | 1 | 60 | 12KW@230 | 79 A | 100 AMP | ||
| 200B | 208 | 3 | 60 | 12KW@230 | 40 A | 50 AMP | |||
|
| |||||||||
GALLONS PER MINUTE | 150 | 200B | 230 | 3 | 60 | 12KW@230 | 44 A | 60 AMP | ||
200B | 460 | 3 | 60 | 12KW@230 | 22 A | 25 AMP | ||||
TEMPERATURES |
| 200B | 208 | 1 | 60 | 14KW@230 | 79 A | 100 AMP | ||
|
| 200B | 230 | 1 | 60 | 14KW@230 | 87 A | 110 AMP | ||
150 | 200B | 208 | 3 | 60 | 14KW@230 | 44 A | 60 AMP | |||
180 | 200B | 230 | 3 | 60 | 14KW@230 | 49 A | 70 AMP | |||
130 | 200B | 460 | 3 | 60 | 14KW@230 | 25 A | 36 AMP | |||
|
|
|
|
|
|
|
| |||
130 | 200 | 208 | 1 | 60 | N/A | 29 A | 40 AMP | |||
|
| |||||||||
NOTE: Always refer to the machine data plate for specific | 200 | 230 | 1 | 60 | N/A | 31 A | 40 AMP | |||
200 | 208 | 3 | 60 | N/A | 15 A | 20 AMP | ||||
electrical and water requirements. The material provided on | 200 | 230 | 3 | 60 | N/A | 16 A | 20 AMP | |||
this page is for reference only and may be | subject to | 200 | 460 | 3 | 60 | N/A | 8 | A | 15 AMP | |
change without notice. |
| 200/LT | 208 | 1 | 60 | N/A | 29 A | 40 AMP | ||
|
| |||||||||
STEAM REQUIREMENTS |
| 200/LT | 230 | 1 | 60 | N/A | 31 A | 40 AMP | ||
| 200/LT | 208 | 3 | 60 | N/A | 15 A | 20 AMP | |||
COIL SIZE | 3/4” | 200/LT | 230 | 3 | 60 | N/A | 16 A | 20 AMP | ||
200/LT | 460 | 3 | 60 | N/A | 8 | A | 15 AMP | |||
STEAM FLOW PRESSURE (P.S.I.) | ||||||||||
|
|
|
|
|
|
|
| |||
CONSUMPTION @ 15 P.S.I. (LBS/HR) | 45 | 200S | 208 | 1 | 60 | N/A | 7 | A | 15 AMP | |
|
| |||||||||
WATER REQUIREMENTS (MINIMUM) |
| 200S | 230 | 1 | 60 | N/A | 7 | A | 15 AMP | |
| 200S | 208 | 3 | 60 | N/A | 4 | A | 15 AMP | ||
|
| |||||||||
INLET TEMPERATURE (200) | 180°F | 200S | 230 | 3 | 60 | N/A | 4 | A | 15 AMP | |
200S | 460 | 3 | 60 | N/A | 4 | A | 15 AMP | |||
INLET TEMPERATURE (200B)(40° Rise) | 140°F | |||||||||
|
|
|
|
|
|
|
| |||
INLET TEMPERATURE (200B)(70° Rise) | 110°F |
|
|
|
|
|
|
|
| |
INLET TEMPERATURE (200LT) | 140°F |
|
|
|
|
|
|
|
| |
INLET TEMPERATURE (200S) | 110°F |
|
|
|
|
|
|
|
| |
GALLONS PER HOUR | 52.2 |
|
|
|
|
|
|
|
| |
GALLONS PER RACK | 0.92 |
|
|
|
|
|
|
|
| |
WATER LINE SIZE NPT | 3/4” |
|
|
|
|
|
|
|
| |
DRAIN LINE SIZE NPT | 1 1/2” |
|
|
|
|
|
|
|
| |
FLOW PRESSURE P.S.I. (Optimum) | 20A5 |
|
|
|
|
|
|
|
| |
MINIMUM CHLORINE REQUIRED (PPM)(200LT) | 50 |
|
|
|
|
|
|
|
|
200 Series Technical Manual