Vulcan-Hart 2XG4BDF, ML-136654, ML-136656, ML-136657, ML-136681 Do not Wash Fabric Envelope, Step

Page 20

GBD_GBDF SERIES GAS FRYERS

INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS® FILTER ENVELOPE

FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RATE WE RECOMMEND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).

Step 1

Discard all oil from the filter vessel, (see pages 23 or 24). When the filter pan is empty, use a spatula and scrape off all debris left on the filter envelope and in the filter pan.

Step 2

Unscrew “S” Tube from filter by turning the Bottom Knurled fitting counter- clockwise.

Step 3

Remove SST Closure Clip by lifting off one side.

Step 4

Remove SST Filter Screen Insert and wash insert with hot water and dry thoroughly. The Filter Screen Insert is dishwasher safe. Place the insert into a new KleenScreen PLUS® Filter envelope.

DO NOT WASH FABRIC ENVELOPE

Step 5

Place Filter Screen Insert into the fabric envelope making sure that the holes line up. Fold over the other end of the envelope and place SST Closure Clip on – hinge over and firmly press clip all the way down to secure and seal filter assembly. Making sure that the folded end is face down; screw “S” Tube Assembly onto the Filter Assembly. Tighten the Bottom Knurled fitting. When tightened, the “S” Tube assembly should be perpendicular to the long side of the filter assembly.

Step 6

Reposition the filter tube into the provided clip. Align filter tube so that the end of the “S” Tube engages the Oil Receptacle fitting each time the drawer is opened and closed.

VULCAN-HART

F-32934 Rev. B (June 2008)

-20-

Image 20
Contents Installation & Operational Manual Important for Your Safety Table of Contents Introduction Ordering PartsUnpacking GeneralInstallation Fryer Model No Device Serial NoCodes and Standards ClearancesLocation United StatesCanada AssemblyFlue Connection Testing the GAS Supply Piping System GAS ConnectionGAS Pressures ALL Models Fryers with CastersElectrical Connection OVER-TEMPERATURE Shutdown CleaningLeveling the Fryer OperationFilling Tank with Shortening Basic Frying InstructionFry Basket Capacity Extending Shortening LifeFry Basket Guidelines Start Button Turning on the FryerTurning OFF the Fryer Extended Shutdown Filtering the OILDraining the Tank Boil OUT ProcedureWeekly or when oil is replaced Cleaning GAS KleenScreen Plus Models Filtering Instructions for KleenScreen Plus Fryers Same Suction Tube Do not Wash Fabric Envelope StepFiltering Procedure OperationQuick Start Guide for Solid State Knob Controls Filtering in 6 Easy Steps Flush and Discard Filtering TIPRemoving Excess Debris from the Screen Filter Boil OUT Procedure Thermal Overload Protection ButtonMaintenance Service in the US and CanadaFlue Vent Inspection Australia