Vulcan-Hart ML-136651, ML-136654, ML-136656, 1G4BD Introduction, Ordering Parts, Unpacking, General

Page 4

GBD_GBDF SERIES GAS FRYERS

INTRODUCTION

GENERAL

Vulcan Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance will result in years of satisfactory performance.

Before installing the fryer, thoroughly read this manual and carefully follow all instruction.

This manual is applicable to model listed on the cover page. Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific.

ORDERING PARTS

Customers may order parts directly from their local authorized service center. If not known, call Vulcan Customer Service at 800-814-7028.

To speed up your order, provide the model number, serial number, gas type, part needed, item part number (if known) and quantity needed.

FRYER CAPACITY

MODEL -

# of Heat Tubes

BTU / Hour

Width Inch (cm)

Shortening lbs. (kg)

GMO

Each Fry Tank

Each Fry Tank

Total System

Each Fry Tank

1G4BD

4

120,000

15.5" (39)

45-50 (21-23)

1G6BD

5

150,000

21.0" (53)

65-70 (29-32)

1G8BD

5

150,000

21.0" (53)

85-90 (39-41)

2G4BDF

4

120,000

31.0" (79)

45-50 (21-23)

3G4BDF

4

120,000

46.5" (118)

45-50 (21-23)

4G4BDF

4

120,000

62.0" (158)

45-50 (21-23)

2G6BDF

5

150,000

42.0" (107)

65-70 (29-32)

3G6BDF

5

150,000

63.0" (160)

65-70 (29-32)

4G6BDF

5

150,000

84.0" (214)

65-70 (29-32)

2G8BDF

5

150,000

42.0" (107)

85-90 (39-41)

3G8BDF

5

150,000

63.0" (160)

85-90 (39-41)

4G8BDF

5

150,000

84.0" (214)

85-90 (39-41)

2XG4BDF

4

120,000

31.0" (79)

45-50 (21-23)

2XG6BDF

5

150,000

42.0" (107)

65-70 (29-32)

2XG8BDF

5

150,000

42.0" (107)

85-90 (39-41)

UNPACKING

This fryer was carefully inspected before leaving the factory. Upon acceptance of the shipment, the transportation company assumes full responsibility for safe delivery.

Immediately after unpacking the fryer, check for possible shipping damage. If the fryer is damaged, save the packaging material and contact the carrier within 15 days of delivery.

VULCAN-HART

F-32934 Rev. B (June 2008)

-4-

Image 4
Contents Installation & Operational Manual Important for Your Safety Table of Contents Introduction Ordering PartsUnpacking GeneralInstallation Fryer Model No Device Serial NoCodes and Standards ClearancesLocation United StatesFlue Connection AssemblyCanada Testing the GAS Supply Piping System GAS ConnectionGAS Pressures ALL Models Fryers with CastersElectrical Connection OVER-TEMPERATURE Shutdown CleaningLeveling the Fryer OperationFilling Tank with Shortening Basic Frying InstructionFry Basket Guidelines Extending Shortening LifeFry Basket Capacity Turning OFF the Fryer Turning on the FryerStart Button Extended Shutdown Filtering the OILWeekly or when oil is replaced Boil OUT ProcedureDraining the Tank Cleaning GAS KleenScreen Plus Models Filtering Instructions for KleenScreen Plus Fryers Same Suction Tube Do not Wash Fabric Envelope StepFiltering Procedure OperationQuick Start Guide for Solid State Knob Controls Filtering in 6 Easy Steps Removing Excess Debris from the Screen Filter Filtering TIPFlush and Discard Boil OUT Procedure Thermal Overload Protection ButtonMaintenance Service in the US and CanadaFlue Vent Inspection Australia