GBD_GBDF SERIES GAS FRYERS

EXTENDED SHUTDOWN

1.Open the door to the fryer. Press the power switch to the OFF position.

2.Thoroughly drain the fryer. Refer to DRAINING THE FRYER.

3.Clean the fryer according to CLEANING.

4.Turn off the main gas shutoff valve.

FILTERING THE OIL

Hot oil and hot parts can cause burns. Use care when operating, cleaning, and servicing the fryer.

Filter shortening at least once a day.

1.A cold fryer will not drain properly. Always filter shortening between 250°F and 350°F. The shortening in the cold zone area will remain hard if not heated properly. If necessary, use the clean-out rod to carefully stir the hard shortening to an area above the cold zone where it will melt.

2.Open the door to the fryer. The power must remain ON for the fryer to filter correctly.

3.Insert the drain extension into the drain valve. Tighten only hand tight.

4.Direct the drain extension into Vulcan’s 85MF mobile filter or equivalent mobile filtering device.

5.Use the provided crumb scoop to remove the heavy debris lying on the bottom of the tank.

6.Slowly open the drain valve to allow oil to flow from the fry tank to the filter pan or discard container. The burners will turn off automatically.

7.When fry tank is empty use the tank brush to remove any additional debris.

8.Close the drain valve.

9.Fill tank with new shortening. Fill to a minimum of the MIN level but no high that halfway between MIN and MAX. Oil will expand as it is heated.

10.Press the start button only after step 9 is fully completed. The fryer will begin to heat the shortening.

VULCAN-HART

F-32934 Rev. B (June 2008)

-14-

Image 14
Contents Installation & Operational Manual Important for Your Safety Table of Contents Unpacking IntroductionOrdering Parts GeneralInstallation Fryer Model No Device Serial NoLocation Codes and StandardsClearances United StatesCanada AssemblyFlue Connection GAS Pressures ALL Models Testing the GAS Supply Piping SystemGAS Connection Fryers with CastersElectrical Connection Leveling the Fryer OVER-TEMPERATURE ShutdownCleaning OperationFilling Tank with Shortening Basic Frying InstructionFry Basket Capacity Extending Shortening LifeFry Basket Guidelines Start Button Turning on the FryerTurning OFF the Fryer Extended Shutdown Filtering the OILDraining the Tank Boil OUT ProcedureWeekly or when oil is replaced Cleaning GAS KleenScreen Plus Models Filtering Instructions for KleenScreen Plus Fryers Same Suction Tube Do not Wash Fabric Envelope StepFiltering Procedure OperationQuick Start Guide for Solid State Knob Controls Filtering in 6 Easy Steps Flush and Discard Filtering TIPRemoving Excess Debris from the Screen Filter Boil OUT Procedure Thermal Overload Protection ButtonFlue Vent Inspection MaintenanceService in the US and Canada Australia