Changing Functions & Options
The controller has been preset at the factory and should operate satisfactory. If you wish to fine tune the unit for your specific application consult the CAL 990O Installation and Operation Manual. Following is a simplified procedure for changing parameters.
OFF ON
1. Mixer MAIN POWER switch in the "ON" position.
BYPASS ACTIVE
2. ACTIVE/BYPASS switch in "BYPASS" position.
3.Press button labeled (p). The display should show a number with a decimal place in it.
* Increase |
CAL 9900 Controls Drawing
MIXER KETTLE OPERATION USING CAL 9900
Note: Temperature probe on mixer bridge must be covered with a minimum of three inches of product to function correctly.
Left of the decimal |
|
|
|
place is the |
|
|
|
OPERATING MODE | CAL 9900 | ˚C | |
|
|
| |
setting (this number |
|
|
|
should be flashing). |
|
|
|
To the right is the | * |
|
|
FUNCTION NUMBER. | p |
| |
4. To change the | CAL 9900 | ˚C | |
OPERATING MODE |
|
|
|
setting push the |
|
|
|
( ) or ( ) |
|
|
|
buttons. | * | p |
|
Cleveland
Range
Factory
Settings
OPERATING FUNCTION MODE NUMBER
0 | 0 |
0 | 1 |
5 | 2 |
0 | 3 |
1. | Open STEAM VALVE completely |
2. | Turn mixer MAIN POWER switch to |
4 steam | 4 |
5 electric |
OFF ON
OFF
HEAT AUTO COOL
BYPASS ACTIVE
| "ON" (CAL 9900 lights up and |
| displays present temperatures). |
3. | Turn HEAT/COOL switch to |
| “OFF/AUTO". |
4. | Turn ACTIVE/BYPASS switch to |
| "BYPASS". The unit should not be |
| heating or cooling at this point. |
5. To move to the |
FUNCTION NUMBER |
(right of the |
decimal) push |
(*) button. |
6. That number |
should now be |
flashing. To move |
to another FUNCTION |
NUMBER push the |
CAL 9900 | ˚C |
* p
CAL 9900 | ˚C |
0 | 5 |
5 | 6 |
|
|
0 | 7 |
|
|
0 | 8 |
|
|
1 | 9 |
|
|
0 | 10 |
|
|
0 | 11 |
|
|
0 | 12 |
|
|
0 | 13 |
|
|
0 | 14 |
5. Push ( ) button on CAL 9900 to read set point |
temperature. (This is the desired product |
* |
temperature). |
( | ) or ( | ) |
buttons. |
|
* p
0 | 15 |
916
6. | To change set point temperature push and |
| hold ( ) button while pushing ( ) or ( ) |
| button.*New set point is determined when |
7. | (*) button is released. |
Add product to kettle. |
8. Turn ACTIVE/BYPASS switch to “ACTIVE”. If the set point
temperature is higher than the product temperature, the kettle will start heating.
Note: For twin kettles, the CAL 9900 will control the kettle the mixer is in.
7. Push ( ) button to |
| CAL 9900 | ˚C |
move to*the left of the |
| ||
|
|
| |
decimal. To change |
|
|
|
the OPERATING MODE |
|
|
|
setting push the |
| * p |
|
( ) or ( ) |
|
| |
|
|
buttons.
8. | When your changes | CAL 9900 | ˚C | |
| are complete push |
|
|
|
| the button labeled |
|
|
|
| (p) again to return |
|
|
|
| to the Process | * | p |
|
| Temperature. |
|
017
0 | 18 |
1 | 19 |
|
|
2 T.A.P | 20 |
0 | |
0 | 21 |
|
|
0 = °C | 22 |
1 = °F | |
6 | 23 |
|
|
24 |
025
--