Cleveland Range (T) MKDL-80-T (-CC), (T) MKDL-125-T (-CC) manual RE-INSTALLING Speed Control Cable

Page 47

RE-INSTALLING SPEED CONTROL CABLE

A

B

G

F

C

DE

Speed Control Assembly

1.Turn sprocket of speed control so that wire."A" is fully extended towards shaft "B".

2.Insert end of cable through bracket "C".

3.Insert wire so it protrudes approximately 1/2" to 5/8" through hole in bolt "D". Tighten bolt and bend end of wire.

4.Bring pump arm "E" up until it hits stop bolt "F" and tighten screw "C".

5.Reassemble unit. Speed control knob will go on pointing toward minimum setting.

6.Turn mixer on with speed control set at minimum setting.

7.If scraper arm is turning, loosen nut "G" and back stop bolt "F" off a few turns. Next loosen screw "C" and slowly pull up cable until scraper arm stops turning. Retighten screw "C". Gently turn stop bolt "F" down until it hits arm. Lock in place by tightening nut "G".

8.Scraper arm should now go from no rotation to fast rotation by turning speed control knob.

NOTE: Mixer may run rough and noisy for one or two hours if air has become trapped in the line.

HYDRAULIC OIL REPLACEMENT PROCEDURE

One of the most important maintenance tasks is to change the hydraulic oil yearly. Under heavy usage the oil should be changed every nine months. It is important to change the oil regularly to prevent its breakdown which leads to the damaging of components.

The oil filter should be changed at the same time as the hydraulic oil. A clean filter prevents particles from damaging the other components in the system.

Replace the hydraulic fluid as follows:

Disconnect power to unit.

Remover the front top panel on the main console.

Remove chrome vent cap from breather pipe located beside electric motor.

Remove plug bolt from bottom left front corner of main console to drain oil into your catch pail.

Remove oil filter.

Replace plug bolt.

Refill unit through breather pipe using approximately 12 U.S. gallons of Tellus 32 hydraulic oil (oil should be 6 1/2" deep in tank).

Install new oil filter (Part# SE50094).

Replace chrome vent cap and front top panel.

Reconnect power to unit.

Run unit to remove any air in the lines.

NOTE: Mixer may run rough and noisy for one or two hours if air has become trapped in the line.

Image 47
Contents Operators Manual For your safety Clearance Requirements GeneralInspection Shipping Damage InstructionsLeveling Moving UnitPiping Connections Electrical Service ConnectionsCompressed AIR Connection Steam Pipe Sizing Piping SchematicSteam Requirements for Kettles Quality Assurance Checklist Some units may not have the following items to test Operating Instructions Item no Description Function Operating Suggestions 2000 Mixer Kettle Operation Using CAL Mixer Kettle Operation Using MRC 7000 1 PEN Cleaning Instructions Care and CleaningProduct Valve Scraper BladesStainless Steel Equipment Care and Cleaning Warranty Service PartsItem no Hydraulic ComponentsKE50294 Mercury Switch FA95055-3 Cleveland Remote Control AssemblyDescription QTY Main Console Controls Item no Description Index Switch ConfigurationSpeed Control Electrical Component Assembly Bracket for Thermostat Solenoid Valve, 1 1/4 100 psi Plumbing Assembly 10 ConsolePlumbing Assembly 18 Console Manual Tilt 10 Console Power Tilt 10/12 Console Power Tilt 10/12 Console Water Meter Assembly 18 Console Water Meter Assembly Console Flush Piston Flush Piston AIR SYSTEM, 10 Console Lubricator Used Prior to Item on Description QTY Used After to For MKDL-40CC Flush Piston AIR Solenoid Valve Butterfly Valve Valves Main Component Reference ChartsMaintenance Steam Trap AIR Line Lubricator OIL Filling ProcedureAIR Filter Replacement Procedure Automatic Dump ValveHydraulic OIL Replacement Procedure RE-INSTALLING Speed Control CableLubrication Disassembly of Switch AssemblyOrdering Information Solenoid Valve MaintenanceCoil Replacement For Cook Chill Direct Steam Mixer Kettles MRC 7000 Enable Mode Procedure 1&2 PENWiring Diagram Twin Kettles Flow Path for Hydraulic System Spare Parts Spare Parts List