Alto-Shaam 1220 manual Electrical connection, Hard wired models

Page 24

i n s t a l l a t i o n

electrical connection

danger

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

danger

APPLIANCES WITH NO CORD

PROVIDED BY FACTORY MUST

BE EQUIPPED WITH A CORD OF

SUFFICIENT LENGTH TO PERMIT

THE APPLIANCE TO BE MOVED

FOR CLEANING.

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

hard wired models:

hard wired models must be equipped with a country certified external allpole disconnection switch with sufficient contact separation.

if a power cord is used for the connection of the product an oil resistant cord like h05rn or h07rn or equivalent must be used.

1.An electrical wiring diagram is located behind the control panel on the left side of the oven. This appliance must be branch circuit protected with proper ampacities, in accordance with the wiring diagram.

2.Wire size for the main incoming power to the unit must match the minimum size listed in the specifications applicable to the specific oven model. For supply connections, locate the wire size posted on the label located on the electrical control box cover, behind the service panel.

3.When connecting to a Delta-B (wild leg) on a

3-phase system, the wild leg must be connected to line 3. Install wiring with a strain relief.

4.Before operating the oven, check all cable connections in the electrical connection area for tightness since connections can loosen during transport.

danger

To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/ NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.

danger

IMPROPER INSTALLATION,

ALTERATION, ADJUSTMENT,

SERVICE, OR MAINTENANCE COULD

RESULT IN SEVERE INJURY, DEATH,

OR CAUSE PROPERTY DAMAGE.

READ THE INSTALLATION,

OPERATING AND MAINTENANCE

INSTRUCTIONS THOROUGHLY

BEFORE INSTALLING OR SERVICING

THIS EQUIPMENT.

note: ce approved appliances must be connected to an electrical circuit that is protected by an external gFci outlet.

NOTE: After both water and electrical connections have been completed, operate the oven

in any cooking mode for a period of 15 minutes and recheck the main power connections at the terminal block to make certain they remain tight.

380-415V:

For CE approved units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an equalization-bonding stud is provided. an equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked

with the following symbol.

CombiTherm® ES series • electric INSTALLATION MANUAL #MN-28897 • 22.

Image 24
Contents ES electric Installation L i v e r y P a c k i n gSafety procedures and precautions N g e rSite Installation Installation codes & StandardsVentilation requirements Positioning on site Minimum Clearance RequirementsLifting Instructions Positioning requirements Accessories Combitherm Cleaning Liquid CE-24750610es 610ES Touch610ES 610esi 610ESi Touch610ESi 610esiN 610ESiN Touch610ESiN 1010es 1010ES Touch1010ES 1010esi 1010ESi Touch1010ESi 1010esiN 35-7/8 910mm Water Drain 33-7/8 860mm Rear714es 714ES Touch714ES 714esi 714ESi Touch714ESi 1018es Water supply shut-off valve and back-flow preventer1018esi 1018esi 1018esi/sk1220es Back 1151mm 1220esi 106mm2020es 60-1/4 x 26-1/4 x 32-11/16 1530mm x 667mm x 830mm2020esi 2020esi 2020esi/skHard wired models Electrical connectionTerminal Block Ground Electrical Connection Following Electrical Connection Mobile equipment restraint Risk of electric shockWater quality requirement Water connections Water requirements Two 2 cold water inlets drinking qualityWater Valve Water drainageE c k l i s t ClearancesFaulty or scaled water level probe Faulty or plugged solenoid valve assemblyWiring or connection issue Incorrect power to the unitProblem with water level probe Connection issue with B-4 probeFaulty B-4 probe Connection issue at B-3 probeTemperature sensor shorted to ground/faulty Faulty drain pumpPlugged or faulty Y-1 solenoid Connection issue at X-3 personality jumperOven Probe Fault Bypass Probe FaultTo 284F Excess Oven TempVentless hood option Condensate drainVentless Hood Power Knob OperationOriginal equipment limited warranty TRansportation damage and claims