Alto-Shaam 1220 manual 1018es, Water supply shut-off valve and back-flow preventer

Page 18

10•18es

 

 

 

30"

 

 

4-11/16" (120mm)

 

 

 

 

(760mm)

 

Water Drain

 

 

 

 

 

 

 

2-5/16" (58mm)

 

 

 

 

 

(Back)

43-7/8"

(1114mm)

41-15/16"

(1064mm)

42-13/16" (1087mm)

40-1/8"

(1019mm)

22-3/8" (568mm) 15-1/2" (393mm)

12-3/4" (323mm)

Untreated Water

Intake (Bottom)

Treated Water

Intake (Bottom)

Electrical Connection

(Bottom)

2" (50mm)

Steam Vents (Top)

69-3/8" (1761mm)

 

7-9/16" (192mm) 32-7/8" (834mm) 40-7/16" (1026mm)

6-1/4" (158mm)

33-1/8"

4-15/16"

 

(840mm)

(125mm)

 

Water Drain (Bottom)

25-5/8" (650mm) 8-11/16" (219mm)

46-7/8" (1190mm)

 

 

 

 

 

 

 

 

dimensions: H x W x D

 

 

 

 

 

 

 

 

 

 

exterior:

 

 

 

 

installation requirements

 

40-7/16" x 43-7/8" x 42-13/16"

(1026mm x 1114mm x 1087mm)

Oven must be installed level.

 

 

 

exterior with recessed door:

 

 

 

 

 

40-7/16" x 47-7/8" x 42-13/16"

(1026mm x 1216mm x 1087mm)

Hood installation is required.

 

 

 

 

 

 

interior:

 

 

 

 

Water supply shut-off valve and back-flow preventer.

 

 

 

 

 

30-3/4" x 23-1/2" x 28-7/16"

(781mm x 596mm x 722mm)

 

 

 

 

 

 

 

 

 

water requirements

 

 

 

 

 

 

water quality minimum standards

 

 

 

 

 

 

 

 

TWO (2) COLD WATER INLETS - DRINKING QUALITY

 

 

using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM

ONE (1) TREATED WATER INLET:

3/4" npT*

* can manifold off of

 

waTer QualiTy sTandards will Void This warranTy.

ONE (1) UNTREATED WATER INLET: 3/4" npT*

one 3/4" line.

 

 

it is the responsibility of the purchaser to ensure that incoming water supply is

LINE PRESSURE:

 

30 to 90 psi 2.8 to 6.2 bar

 

 

compliant with the specifications listed through adequate treatment measures.

WATER DRAIN: 1-1/2" connecTion wiTh a 2" MiniMuM air

 

installation of the combiguardTM water Filtration system is recommended, but

gap insTalled as close To The oVen as possiBle

 

 

this system may not address all water quality issues present.

 

 

 

 

 

 

clearance requirements

 

 

 

 

 

 

 

Contaminant Inlet Water Requirements (untreated water)

 

 

LEFT

6" (152mm) RECOMMENDED SERVICE ACCESS: 18" (457mm)

 

 

 

Free chlorine less than 0.1 ppm (mg/l)

 

 

 

 

 

hardness less than 3 gpg (52 ppm)

 

 

 

20" (508mm) FROM HEAT PRODUCING EQUIPMENT

 

 

 

 

 

 

 

 

 

chloride less than 30 ppm (mg/l)

RIGHT

4" (102mm)

TOP: 20" (508mm) For air MoVeMenT

 

 

 

 

 

 

 

ph 7.0 to 8.5

 

 

BACK

4" (102mm)

BOTTOM: 5-1/8" (130mm) For legs

 

 

 

alkalinity less than 50 ppm (mg/l)

counTer-Top insTallaTions MusT MainTain 4" (102mm) MiniMuM

 

 

 

silica less than 12 ppm (mg/l)

 

 

Total dissolved solids (tds) less than 60 ppm

clearance FroM counTer surFace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

electrical (d e d i c a t e d c i r c u i t r e q u i r e d )

 

 

 

 

 

 

 

 

voltage

phase

cycle/hz

 

 

awg

 

amps

kW

-240

 

at 208

3

 

 

60

 

3 Wire plus ground

61.3/ph

22.0

208

 

at 240

 

 

 

 

 

 

 

awg 2

 

70.0/ph

29.2

 

 

 

 

 

 

 

 

 

 

0-415

 

at 380

3

 

 

50

 

4 Wire plus ground

33.5/ph

22.0

38

 

at 415

 

 

 

 

 

 

 

awg 6

 

40.7/ph

29.2

 

 

 

 

 

 

 

 

 

 

0-480

 

at 440

3*

 

 

60

 

3 Wire plus ground

36.0/ph

27.2

44

 

at 480

 

 

 

 

 

 

 

awg 6

 

43.5/ph

36.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* electrical service charge applies

 

 

 

 

weight

 

 

 

 

capacity

 

 

 

 

 

 

net

 

514 lb

(233 kg)

 

FULL-SIZE PANS:

20" x 12" x 2-1/2"

Twenty (20)

ship

 

650 lb

(295 kg)

 

 

 

gn 1/1:

530 x 325 x 65mm

Twenty (20)

 

 

 

 

gn 2/1:

650 x 530 x 65mm

Ten (10)

crate dimensions: (l x w x h)

 

 

 

 

 

 

FULL-SIZE SHEET PANS:*

18" x 26" x 1"

Ten (10)

 

 

 

53" x 45"

x 49"

 

 

on wire shelves only

 

 

 

 

 

 

 

 

 

 

 

 

240 lb (109 kg) maximum

 

 

 

(1346 x 1143 x 1245mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

volume maximum: 150 quarts (190 liters)

 

 

 

 

 

 

 

 

 

*additional wire shelves required for maximum capacity

CombiTherm® ES series • electric INSTALLATION MANUAL #MN-28897 • 16.

Image 18
Contents ES electric Installation L i v e r y P a c k i n gSafety procedures and precautions N g e rSite Installation Installation codes & StandardsVentilation requirements Positioning on site Minimum Clearance RequirementsLifting Instructions Positioning requirements Accessories Combitherm Cleaning Liquid CE-24750610es 610ES Touch610ES 610esi 610ESi Touch610ESi 610esiN 610ESiN Touch610ESiN 1010es 1010ES Touch1010ES 1010esi 1010ESi Touch1010ESi 1010esiN 35-7/8 910mm Water Drain 33-7/8 860mm Rear714es 714ES Touch714ES 714esi 714ESi Touch714ESi 1018es Water supply shut-off valve and back-flow preventer1018esi 1018esi 1018esi/sk1220es Back 1151mm1220esi 106mm2020es 60-1/4 x 26-1/4 x 32-11/16 1530mm x 667mm x 830mm2020esi 2020esi 2020esi/skHard wired models Electrical connectionTerminal Block Ground Electrical Connection Following Electrical Connection Mobile equipment restraint Risk of electric shockWater quality requirement Water connections Water requirements Two 2 cold water inlets drinking qualityWater Valve Water drainageE c k l i s t ClearancesWiring or connection issue Faulty or scaled water level probeFaulty or plugged solenoid valve assembly Incorrect power to the unitFaulty B-4 probe Problem with water level probeConnection issue with B-4 probe Connection issue at B-3 probePlugged or faulty Y-1 solenoid Temperature sensor shorted to ground/faultyFaulty drain pump Connection issue at X-3 personality jumperTo 284F Oven Probe FaultBypass Probe Fault Excess Oven TempVentless hood option Condensate drainVentless Hood Power Knob OperationOriginal equipment limited warranty TRansportation damage and claims