Alto-Shaam 1220 manual 610esi, 610ESi Touch

Page 11

15-7/8"

2-3/16" (56mm)

3-3/4" (95mm)

(403mm) 13-1/2" (343mm) 11-1/8" (283mm)

30" (761mm)

Water Drain (Back)

 

 

(Top)

 

 

 

 

Untreated Water

 

Vent

 

Intake (Bottom)

 

 

 

Steam

(1538mm)

Treated Water

 

Intake (Bottom)

 

 

 

Electrical Connection

 

 

 

(Bottom)

 

 

-9/16"

2" (50mm)

 

 

 

 

60

 

 

 

43-7/8" (1114mm) 41-15/16" (1064mm)

 

26-1/2" (673mm)

3/16" (893mm)

 

7-9/16" (192mm)

35-

33-1/8" (840mm)

4-15/16"

(125mm)

 

6•10esi

34-1/16" (864mm) 31-3/8" (796mm)

(161mm)

WATER

6-3/8"

DRAIN

 

 

 

7-9/16" 17-15/16"

(191mm) (456mm)

49-1/8" (1247mm)

stacking combination DIMENSIONS: H x W x D

 

 

dimensions: h x w x d

 

6.10es over 6.10es

66-3/4" x 44" x 36-5/8" (1693 x 1115 x 930mm)

 

 

EXTERIOR:

 

 

 

6.10es over 10.10es

73-1/8" x 44" x 36-5/8" (1857 x 1115 x 930mm)

 

 

 

35-3/16" x 43-7/8" x 34-1/16" (893mm x 1114mm x 864mm)

6.10es over 7.14es

67" x 44" x 43" (1701 x 1115 x 1090mm)

 

 

EXTERIOR WITH RECESSED DOOR:

 

6.10es over 10.18es

72-3/4" x 44" x 43" (1845 x 1115 x 1090mm)

 

 

 

35-3/16" x 47-7/8" x 34-1/16" (893mm x 1216mm x 864mm)

Mobile option with 5" (127mm) casters will add 2" (51mm) to the overall height

 

INTERIOR:

 

 

 

6.10es over ASC-4E 74" x 44" x 44-1/2" (1878 x 1115 x 1130mm)

 

 

 

17-3/4" x 23-1/2" x 21-1/16" (450mm x 597mm x 535mm)

water requirements

 

 

 

 

 

 

water quality minimum standards

 

 

 

 

 

TWO (2) COLD WATER INLETS - DRINKING QUALITY

 

 

using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM

ONE (1) TREATED WATER INLET:

 

3/4" npT*

* can manifold off of

 

waTer QualiTy sTandards will Void This warranTy.

ONE (1) UNTREATED WATER INLET: 3/4" npT*

one 3/4" line.

 

 

it is the responsibility of the purchaser to ensure that incoming water supply is

LINE PRESSURE:

 

 

 

30 to 90 psi 2.8 to 6.2 bar

 

 

compliant with the specifications listed through adequate treatment measures.

WATER DRAIN: 1-1/2" connecTion wiTh a 2" MiniMuM air

 

installation of the combiguardTM water Filtration system is recommended, but

gap insTalled as close To The oVen as possiBle

 

 

this system may not address all water quality issues present.

 

 

 

 

 

 

 

 

clearance requirements

 

 

 

 

 

 

 

Contaminant Inlet Water Requirements (untreated water)

LEFT

6" (152mm) RECOMMENDED SERVICE ACCESS: 18" (457mm)

 

 

 

 

Free chlorine less than 0.1 ppm (mg/l)

 

 

 

 

 

hardness less than 3 gpg (52 ppm)

 

20" (508mm) FROM HEAT PRODUCING EQUIPMENT

 

 

 

 

 

 

 

 

 

 

 

chloride less than 30 ppm (mg/l)

RIGHT

4" (102mm)

TOP: 20" (508mm) For air MoVeMenT

 

 

 

 

 

 

 

 

 

 

ph 7.0 to 8.5

 

BACK

4" (102mm)

BOTTOM: 5-1/8" (130mm) For legs

 

 

 

 

 

alkalinity less than 50 ppm (mg/l)

counTer-Top insTallaTions MusT MainTain 4" (102mm) MiniMuM

 

 

 

 

 

silica less than 12 ppm (mg/l)

 

 

 

Total dissolved solids (tds) less than 60 ppm

 

clearance FroM counTer surFace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

installation requirements

 

 

 

 

 

 

 

 

 

• Oven must be installed level.

 

 

 

• Hood installation is required.

 

 

 

• Water supply shut-off valve and back-flow preventer when required by local code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

electrical (DEDICATED CIRCUIT REQUIRED)

 

 

 

 

 

 

 

 

combismoker®

Model

VolTage

ph

 

hZ

aMps

kw

 

 

awg

cord & plug

 

additional kw

6•10ESi Touch

208 – 240

1*

60

44.0 - 50.0

9.1 - 12.0

 

awg 6

no cord or plug

 

+ .7 kw

 

 

208 – 240

3

60

25.2 - 27.0/ph

9.1 - 11.3

 

awg 8

no cord or plug

 

+ .7 kw

 

 

380 – 415

3

50

14.0 - 16.3/ph

9.0 - 11.7

 

awg 12

no cord or plug

 

+ .7 kw

6•10ESi

 

208 – 240

1*

60

43.4 - 48.7

9.0 - 11.7

 

awg 6

no cord or plug

 

+ .7 kw

 

 

208 – 240

3

60

25.0 - 28.2/ph

9.0 - 11.7

 

awg 8

no cord or plug

 

+ .7 kw

 

 

380 – 415

3

50

14.0 - 16.3/ph

9.0 - 11.7

 

awg 12

no cord or plug

 

+ .7 kw

 

 

*elecTrical serVice charge applies

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

weight

 

 

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

neT

285 lb

(129 kg)

 

 

Full-siZe pans:

 

20" x 12" x 2-1/2"

six (6)

 

ship

415 lb

(188 kg)

 

 

gn 1/1:

 

530 x 325 x 65mm

six (6)

 

 

 

 

 

 

 

 

gn 2/1:

 

650 x 530 x 65mm

Three (3)

 

craTe diMensions: (l x w x h)

 

halF-siZe sheeT pans:*

 

 

18" x 13" x 1"

Five (5)

 

 

53" x 45" x 49"

 

 

 

on wire shelVes only

 

 

 

 

 

 

 

 

(1346 x 1143 x 1245mm)

 

 

 

 

 

 

 

72 lb (33 kg) MaXiMuM

 

 

 

 

 

 

 

 

 

VoluMe MaXiMuM: 45 quarts (57 liters)

 

 

 

 

 

 

 

*addiTional wire shelVes reQuired For MaXiMuM capaciTy

 

CombiTherm® ES series • electric INSTALLATION MANUAL #MN-28897 • 9.

Image 11
Contents ES electric Installation P a c k i n g L i v e r yN g e r Safety procedures and precautionsVentilation requirements Site InstallationInstallation codes & Standards Minimum Clearance Requirements Positioning on siteLifting Instructions Positioning requirements Combitherm Cleaning Liquid CE-24750 Accessories610ES 610es610ES Touch 610ESi 610esi610ESi Touch 610ESiN 610esiN610ESiN Touch 1010ES 1010es1010ES Touch 1010ESi 1010esi1010ESi Touch 35-7/8 910mm Water Drain 33-7/8 860mm Rear 1010esiN714ES 714es714ES Touch 714ESi 714esi714ESi Touch Water supply shut-off valve and back-flow preventer 1018es1018esi 1018esi/sk 1018esiBack 1151mm 1220es106mm 1220esi60-1/4 x 26-1/4 x 32-11/16 1530mm x 667mm x 830mm 2020es2020esi 2020esi/sk 2020esiElectrical connection Hard wired modelsTerminal Block Ground Electrical Connection Following Electrical Connection Risk of electric shock Mobile equipment restraintWater quality requirement Water requirements Two 2 cold water inlets drinking quality Water connectionsWater drainage Water ValveClearances E c k l i s tIncorrect power to the unit Faulty or scaled water level probeFaulty or plugged solenoid valve assembly Wiring or connection issueConnection issue at B-3 probe Problem with water level probeConnection issue with B-4 probe Faulty B-4 probeConnection issue at X-3 personality jumper Temperature sensor shorted to ground/faultyFaulty drain pump Plugged or faulty Y-1 solenoidExcess Oven Temp Oven Probe FaultBypass Probe Fault To 284FCondensate drain Ventless hood optionOperation Ventless Hood Power KnobOriginal equipment limited warranty TRansportation damage and claims