Alto-Shaam 1220 manual Lifting Instructions

Page 7

i n s t a l l a t i o n

site INSTALLATION

Lifting Instructions

Remove banding before lifting. Place a spacer board(s) 24” in length, with a minimum height of 1-1/2” (mobile base units require 2-1/4” minimum height), on each fork to prevent damaging the door drip tray. Lift the unit from the front

only, never from the side.

Fork

24”

Spacer

Boards

Front View

Fork

Adjust the forks so that they do not damage any of the components under the unit. The left fork should be located between the left legs and the door handle. The right fork should be located as close to the right legs as possible. Lift the unit high enough to remove the wooden pallet. Have a second person hold the unit from shifting. When moving

the unit, drive slowly, keep it low to the ground, and use extreme caution.

Center

of Leg

Gravity

24” Spacer Leg Board

Fork

 

Top View

 

Do not lift in

 

 

 

 

 

 

 

 

 

 

 

 

this area!

 

 

 

 

Damage to the Leg

 

 

 

 

components

 

 

 

 

32”

will result.

24”

Max.

 

Spacer

Fork

Leg

Board

Depth

(Front)

Fork

Door Handle

CombiTherm® ES series • electric INSTALLATION MANUAL #MN-28897 • 5.

Image 7
Contents ES electric Installation P a c k i n g L i v e r y N g e r Safety procedures and precautionsInstallation codes & Standards Site InstallationVentilation requirements Minimum Clearance Requirements Positioning on siteLifting Instructions Positioning requirements Combitherm Cleaning Liquid CE-24750 Accessories610ES Touch 610es610ES 610ESi Touch 610esi610ESi 610ESiN Touch 610esiN610ESiN 1010ES Touch 1010es1010ES 1010ESi Touch 1010esi1010ESi 35-7/8 910mm Water Drain 33-7/8 860mm Rear 1010esiN714ES Touch 714es714ES 714ESi Touch 714esi714ESi Water supply shut-off valve and back-flow preventer 1018es1018esi 1018esi/sk 1018esiBack 1151mm 1220es106mm 1220esi60-1/4 x 26-1/4 x 32-11/16 1530mm x 667mm x 830mm 2020es2020esi 2020esi/sk 2020esiElectrical connection Hard wired modelsTerminal Block Ground Electrical Connection Following Electrical Connection Risk of electric shock Mobile equipment restraintWater quality requirement Water requirements Two 2 cold water inlets drinking quality Water connectionsWater drainage Water ValveClearances E c k l i s tIncorrect power to the unit Faulty or scaled water level probeFaulty or plugged solenoid valve assembly Wiring or connection issueConnection issue at B-3 probe Problem with water level probeConnection issue with B-4 probe Faulty B-4 probeConnection issue at X-3 personality jumper Temperature sensor shorted to ground/faultyFaulty drain pump Plugged or faulty Y-1 solenoidExcess Oven Temp Oven Probe FaultBypass Probe Fault To 284FCondensate drain Ventless hood optionOperation Ventless Hood Power KnobOriginal equipment limited warranty TRansportation damage and claims