i n s t a l l a t i o n

electrical connection

motor with rotation direction

electrical connection

terminal block

ground

electrical panel

warning

FOLLOWING ELECTRICAL CONNECTION,

THE FAN MuSt ROTATE IN THE SAME

DIRECTION AS THE ARROW LOCATED

ON THE OVEN FAN MOTOR.

T H I S A P P L I A N C E W I L L N O T F U N C T I O N

P R O P E R L Y A N D D A M A G E C A N O C C U R I F T H E M O T O R R O T A T I O N I S N O T C O R R E C T .

tO CHANGE MOtOR dIRECtION,

EXCHANGE tWO OF tHE INCOMING pHASES.

danger

ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES.

CombiTherm® ES series • electric INSTALLATION MANUAL #MN-28897 • 24.

Image 26
Contents ES electric Installation L i v e r y P a c k i n gSafety procedures and precautions N g e rVentilation requirements Site InstallationInstallation codes & Standards Positioning on site Minimum Clearance RequirementsLifting Instructions Positioning requirements Accessories Combitherm Cleaning Liquid CE-24750610ES 610es610ES Touch 610ESi 610esi610ESi Touch 610ESiN 610esiN610ESiN Touch 1010ES 1010es1010ES Touch 1010ESi 1010esi1010ESi Touch 1010esiN 35-7/8 910mm Water Drain 33-7/8 860mm Rear714ES 714es714ES Touch 714ESi 714esi714ESi Touch 1018es Water supply shut-off valve and back-flow preventer1018esi 1018esi 1018esi/sk1220es Back 1151mm1220esi 106mm2020es 60-1/4 x 26-1/4 x 32-11/16 1530mm x 667mm x 830mm 2020esi 2020esi 2020esi/skHard wired models Electrical connectionTerminal Block Ground Electrical Connection Following Electrical Connection Mobile equipment restraint Risk of electric shockWater quality requirement Water connections Water requirements Two 2 cold water inlets drinking qualityWater Valve Water drainageE c k l i s t ClearancesWiring or connection issue Faulty or scaled water level probeFaulty or plugged solenoid valve assembly Incorrect power to the unitFaulty B-4 probe Problem with water level probeConnection issue with B-4 probe Connection issue at B-3 probePlugged or faulty Y-1 solenoid Temperature sensor shorted to ground/faultyFaulty drain pump Connection issue at X-3 personality jumperTo 284F Oven Probe FaultBypass Probe Fault Excess Oven TempVentless hood option Condensate drainVentless Hood Power Knob OperationOriginal equipment limited warranty TRansportation damage and claims
Related manuals
Manual 41 pages 12.09 Kb