i n s t a l l a t i o n

water quality requirement

Use a drinking quality, cold water supply only

water quality is of critical importance when installing steam producing equipment of any kind, particularly high temperature steam producing equipment. water that is perfectly safe to drink is composed of chemical characteristics that directly affect the metal surfaces of steam producing equipment. These chemical characteristics differ greatly from region to region throughout the u.s. and the world. varying combinations of ph; alkalinity; hardness; chlorides; total dissolved solids; and other chemical characteristics, when subjected to high temperatures, will cause water to have a tendency to either scale or corrode.

alto-shaam has consulted with people who understand the properties of water in order to provide water quality standards that meet the broadest possible range of acceptable water quality requirements to help protect your investment.

we strongly urge water testing to ascertain the water quality on site prior to the installation of any steam producing equipment. since water quality is an important issue, alto-shaam is committed to provide as much information as possible to help protect the investment made in this equipment.

a combiguard™ water Filtration system can be purchased as an option for installation on the combitherm oven. This filter, when properly installed, maintained, and combined with the required levels of steam generating equipment maintenance, will help lessen the affect water has on metal surfaces. it will not, however, provide complete protection against all water damage from region to region.

due to the complexity of water chemistry, it is important to understand that water quality plays a significant role in the longevity of steam producing equipment. water quality and required maintenance of steam generating equipment is the direct responsibility of the owner/operator. damage incurred as a direct result of poor water quality and/or surfaces affected by water quality is also the responsibility of the owner/operator. damage due to water quality that does not meet the minimum standards shown below is not covered under the alto-shaam combitherm warranty.

alto-shaam will continue our efforts to provide viable solutions to ease the impact of water quality as it relates to steam generating equipment.

ALTO-SHAAM COMBITHERM WATER QUALITY MINIMUM STANDARDS

CONTAMINANT

INLET WATER REQUIREMENTS (UNTREATED WATER)

Free Chlorine

Less than 0.1 ppm (mg\L)

Hardness

Less than 3 gpg (52 ppm)

 

 

Chloride

Less than 30 ppm (mg\L)

 

 

pH

7.0 to 8.5

 

 

Alkalinity

Less than 50 ppm (mg\L)

Silica

Less than 12 ppm (mg\L)

Total Dissolved Solids (tds)

Less than 60 ppm

warning

tO pREVENt WAtER pIpES OR HOSES FROM buRStING, INCOMING WAtER SuppLy SHOuLd bE tuRNEd OFF WHEN tHE AppLIANCE IS NOt IN uSE.

warning

WAtER SuppLy MuSt bE OpEN WHEN CLEANING pROGRAM IS ACtIVAtEd.

VERIFy WAtER SuppLy bEFORE StARtING CLEANING pROGRAM.

CombiTherm® ES series • electric INSTALLATION MANUAL #MN-28897 • 26.

Image 28
Contents ES electric Installation L i v e r y P a c k i n gSafety procedures and precautions N g e rInstallation codes & Standards Site InstallationVentilation requirements Positioning on site Minimum Clearance RequirementsLifting Instructions Positioning requirements Accessories Combitherm Cleaning Liquid CE-24750610ES Touch 610es610ES 610ESi Touch 610esi610ESi 610ESiN Touch 610esiN610ESiN 1010ES Touch 1010es1010ES 1010ESi Touch 1010esi1010ESi 1010esiN 35-7/8 910mm Water Drain 33-7/8 860mm Rear714ES Touch 714es714ES 714ESi Touch 714esi714ESi 1018es Water supply shut-off valve and back-flow preventer1018esi 1018esi 1018esi/sk1220es Back 1151mm1220esi 106mm2020es 60-1/4 x 26-1/4 x 32-11/16 1530mm x 667mm x 830mm2020esi 2020esi 2020esi/skHard wired models Electrical connection Terminal Block Ground Electrical Connection Following Electrical Connection Mobile equipment restraint Risk of electric shockWater quality requirement Water connections Water requirements Two 2 cold water inlets drinking qualityWater Valve Water drainageE c k l i s t ClearancesFaulty or scaled water level probe Faulty or plugged solenoid valve assemblyWiring or connection issue Incorrect power to the unitProblem with water level probe Connection issue with B-4 probeFaulty B-4 probe Connection issue at B-3 probeTemperature sensor shorted to ground/faulty Faulty drain pumpPlugged or faulty Y-1 solenoid Connection issue at X-3 personality jumperOven Probe Fault Bypass Probe FaultTo 284F Excess Oven TempVentless hood option Condensate drainVentless Hood Power Knob OperationOriginal equipment limited warranty TRansportation damage and claims