Alto-Shaam 1220 Temperature sensor shorted to ground/faulty, Scale plugging drain pump, E80, E81

Page 34

i n s t a l l a t i o n

ERROR CODES AND REASONS (continued)

Error

Display Shows

When does the error occur?

Possible reason

Code

 

 

 

 

 

 

 

E29

Probe Short to Frame

Activated if one or more of the temperature

• Connection issue at any of the temperature

 

 

sensors were connected to GND for 5 seconds.

sensors.

 

 

 

• Temperature sensor shorted to ground/faulty.

 

 

 

 

E34

DE (Drain) Pump Failure

Activated if water level did not drop below

• Problem with water level probe.

 

 

the low level sensor in the generator during a

• Scale build-up inside steam generator.

 

 

steam generator flush.

 

 

 

 

 

 

• Scale plugging drain pump.

 

 

 

• Faulty drain pump.

 

 

 

 

E35

Venting Error

Activated when vent switch reads open (vent

• Alignment issue between motor cam and

 

 

closed) when it should be closed (vent open), or

micro switch.

 

 

when it reads closed (vent open) when it should

• Connection issue at micro switch.

 

 

be open (vent closed).

 

 

 

 

• Connection issue at control.

 

 

 

• Faulty vent switch.

 

 

 

• Faulty vent motor.

 

 

 

 

E36

Steam Temp High

Activated when oven temperature probe (N-6)

• Water supply is shut off while unit is running

 

 

measures a temperature in excess of 395°F

in Steam or Combi mode.

 

 

when running in Steam or Combi mode.

• Plugged or faulty Y-1 solenoid.

 

 

 

 

 

 

• Obstruction between Y-01 solenoid and water

 

 

 

inlet.

 

 

 

 

E80

ID Error

Control is unable to detect whether unit is gas

• Connection issue at X-3 personality jumper.

 

 

or electric.

• Faulty control.

 

 

 

 

 

 

 

E81

Program Memory Error

Temperature value or time value of a program

• Program was generated in °C and control has

 

 

step is not allowed.

been switched to °F.

 

 

 

• Program was generated in °F and control has

 

 

 

been switched to °C.

 

 

 

 

E82

WP Error

Temperature value or time value of current

• Delete program and reinstall.

 

 

cooking algorithm is out of allowed array.

 

 

 

 

 

E83

Algo Error

Cooking algorithm sent by operating module

• Software versions of control unit and

 

 

(BM) is unknown to control unit (SM).

operating module are incompatible.

 

 

 

• Software error in operating module.

 

 

 

 

E96

Connection Error

No or bad communication between control unit

• Connection issue at ribbon cable on display or

 

 

(SM) and operating module (BM).

relay board.

 

 

 

• Faulty ribbon cable.

 

 

 

• Software versions of control unit and

 

 

 

operating module are incompatible.

 

 

 

 

continued on next page

CombiTherm® ES series • electric INSTALLATION MANUAL #MN-28897 • 32.

Image 34
Contents ES electric Installation L i v e r y P a c k i n gSafety procedures and precautions N g e rInstallation codes & Standards Site InstallationVentilation requirements Positioning on site Minimum Clearance RequirementsLifting Instructions Positioning requirements Accessories Combitherm Cleaning Liquid CE-24750610ES Touch 610es610ES 610ESi Touch 610esi610ESi 610ESiN Touch 610esiN610ESiN 1010ES Touch 1010es1010ES 1010ESi Touch 1010esi1010ESi 1010esiN 35-7/8 910mm Water Drain 33-7/8 860mm Rear714ES Touch 714es714ES 714ESi Touch 714esi714ESi 1018es Water supply shut-off valve and back-flow preventer1018esi 1018esi 1018esi/sk1220es Back 1151mm1220esi 106mm2020es 60-1/4 x 26-1/4 x 32-11/16 1530mm x 667mm x 830mm2020esi 2020esi 2020esi/skHard wired models Electrical connectionTerminal Block Ground Electrical Connection Following Electrical Connection Mobile equipment restraint Risk of electric shockWater quality requirement Water connections Water requirements Two 2 cold water inlets drinking qualityWater Valve Water drainage E c k l i s t ClearancesWiring or connection issue Faulty or scaled water level probeFaulty or plugged solenoid valve assembly Incorrect power to the unitFaulty B-4 probe Problem with water level probeConnection issue with B-4 probe Connection issue at B-3 probePlugged or faulty Y-1 solenoid Temperature sensor shorted to ground/faultyFaulty drain pump Connection issue at X-3 personality jumperTo 284F Oven Probe FaultBypass Probe Fault Excess Oven TempVentless hood option Condensate drainVentless Hood Power Knob OperationOriginal equipment limited warranty TRansportation damage and claims