Contents
Liebert XDP with Liebert iCOM Control
Page
Table of Contents
Alarm Descriptions and Solutions
Specifications
Start the Liebert XDP with Liebert Icom
Figures
Tables
Important Safety Instructions
Example XDP160RA
Pumping Unit Redundancy Place holder Revision Level Liebert
= 460V-3ph-60Hz Place holder
Minimum Load
General Product Information
Equipment Inspection
Product/System Description
Handling the Liebert XDP While it is on Skid and Packaged
Equipment Handling
Unpacking the Liebert XDP
Removing the Unit from the Skid Using a Forklift
Use a forklift to remove the Liebert XDP from the skid
Removing the Unit from the Skid using Rigging
Spreader Bars Bracket
Moving the Liebert XDP Using Piano Jacks
Securing the Liebert XDP to piano jacks
Removing the Unit from the Piano Jacks
Liebert XDP dimensions
Mechanical Considerations
Positioning the Liebert XDP
Electrical Considerations
Unit piping outlet connection sizes, inches, OD Cu
Model Pipe Connection Point 50/60 Hz
Front view of Liebert XDP and electrical enclosure
Connecting High-Voltage Cables
High voltage connections-60Hz
High voltage connections-50Hz
Extra Low Voltage ELV Connections
Connecting the remote temperature/humidity sensors
DIP switch and jumper settings
DIP Switch and Jumper Settings for Remote Sensors
Liebert XDP extra low voltage field connections points
Field Connections-Optional for All Units
Suggested remote sensor placement
Remote Sensor Installation-Proper Placement
Supply, return pipe sizes for refrigerant loop
European Union Fluorinated Greenhouse Gas Requirements
Connection Sizes
Recommended Pipe Size
Liebert XDP
Piping Installation Methods
Piping Installation-R-134a Pumped Circuit
Liebert XDP Interconnection with Liebert XD Cooling Modules
Required Number of Open
Piping Mains
Bypass Flow Controller
Bypass flow controllers for a Liebert XDP-based system
Bypass flow controller arrangement
Piping Details-Shutoff/Isolation Valves
Evacuation and Leak Check-R-134a Pumped Circuit
Insulation
Floor Supply Return Liebert
System refrigerant charge for the supply and return mains
Filling the Pumped Circuit-R-134a
Calculating Refrigerant Charge-Example
Calculating refrigerant charge-example
Worksheet to calculate refrigerant charge
Checklist for Proper Installation
Escape Key Down Arrow Key
Liebert iCOM Components and Functions
Display Lamp Indicators
Keyboard icons and functions
Icon Key Name Function
Accessing Menus and Settings Viewing Data
Navigating Through the Liebert iCOM Display
Unit Sensor a Sensor B Pump Operation Roo m Data Room Data
ACK High Chilled Water Temp
Cooling Module Overview
Entering the password
Entering the Password
English US
Changing Liebert iCOM’s Display Settings
Changing Operational Settings
Highlight the setting to be changed by pressing Enter
Liebert iCOM User Menu Icons and Legend
Graphical Data Record
Liebert XDP User Menu screen
Liebert iCOM User Menu Screens
Spare Parts
Event Log
SET Alarms page 1
Sensor Data screen, page 1
Sensor Data screen, page 2
U401 U402
XDV8SK
Online
XDO20SK 20 KW
XDH32SK
Settings
Liebert iCOM Service Menu Icons and Legend
Setpoints Maintenance Diagnostics Set Alarms
Service Mode
Liebert XDP Service Menu screen
Liebert iCOM Service Menu Screens
Liebert iCOM Control-Firmware Version XP1.00.010.STD
Maintenance-Basic Settings screen, page 1
Maintenance-Pump 1 Settings screen, page 2
Maintenance-Pump 2 Settings screen, page 3
Diagnostics/Service Mode screen, page 1
Manual Mode Control Type-Not currently used
Diagnostics/Service Mode screen, page 5
Set Alarms screen, page 1
Set Alarms screen, page 2
High Temp Sensor B Enable ALM
Delay EN-DIS Type
High Temp Sensor a Enable ALM
LOW Temp Sensor a Enable ALM
Loss of Flow Pump Enable ALM
High Refrigerant Temp Enable ALM
LOW Refrigerant Temp Enable ALM
Supply Refrigerant Sensor Enable ALM
Smoke Detected Enable ALM
Condensation Detected Enable ALM
FAN Failure Enable ALM
Customer Input Enable ALM
S601
S612
S801
GBP
MAC
Unit
System/Network Setup screen-Unit, page 1
S834 S835
S401
Sensor Failure Enable ALM
Node ID Delay EN-DIS Type
Condensation Detected Enable
Local Module Shutdown Enable ALM
Node ID Delay EN-DIS Type
Checklist for Liebert XDP Startup
Liebert XDP pump light indicator-208V and 400V units
Indicator Lights Description Green Red
System R-134a liquid level at 160kW load
Starting the Liebert XDP with Liebert iCOM Controller
Alarm Descriptions
Alarm Descriptions and Solutions
Unit Is Off By Pump Short Cycle
System Shutdown Causes
Unit Is Off By Refrig Sens Fail
Unit Is Off By High CW Temp
Symptom Possible Cause Check or Remedy
Troubleshooting the Liebert XDP
See Clogged Filter Dryer and/or Impeller symptom
Fluorinated Greenhouse Gas Requirements
Maintenance
Liebert XDP160 specifications
2006/42/EC 2004/108/EC 2006/95/EC 97/23/EC
Liebert Corporation Dearborn Drive Box Columbus, OH
Care
Ne t
Is t
Twor k