Contents
Liebert XDP with Liebert iCOM Control
Page
Table of Contents
Alarm Descriptions and Solutions
Specifications
Start the Liebert XDP with Liebert Icom
Figures
Tables
Important Safety Instructions
Example XDP160RA
Pumping Unit Redundancy Place holder Revision Level Liebert
= 460V-3ph-60Hz Place holder
General Product Information
Equipment Inspection
Product/System Description
Minimum Load
Equipment Handling
Handling the Liebert XDP While it is on Skid and Packaged
Removing the Unit from the Skid Using a Forklift
Unpacking the Liebert XDP
Removing the Unit from the Skid using Rigging
Use a forklift to remove the Liebert XDP from the skid
Moving the Liebert XDP Using Piano Jacks
Spreader Bars Bracket
Removing the Unit from the Piano Jacks
Securing the Liebert XDP to piano jacks
Liebert XDP dimensions
Mechanical Considerations
Positioning the Liebert XDP
Electrical Considerations
Unit piping outlet connection sizes, inches, OD Cu
Model Pipe Connection Point 50/60 Hz
Connecting High-Voltage Cables
Front view of Liebert XDP and electrical enclosure
High voltage connections-60Hz
Extra Low Voltage ELV Connections
High voltage connections-50Hz
Connecting the remote temperature/humidity sensors
DIP Switch and Jumper Settings for Remote Sensors
DIP switch and jumper settings
Field Connections-Optional for All Units
Liebert XDP extra low voltage field connections points
Remote Sensor Installation-Proper Placement
Suggested remote sensor placement
European Union Fluorinated Greenhouse Gas Requirements
Connection Sizes
Recommended Pipe Size
Supply, return pipe sizes for refrigerant loop
Piping Installation Methods
Piping Installation-R-134a Pumped Circuit
Liebert XDP Interconnection with Liebert XD Cooling Modules
Liebert XDP
Piping Mains
Bypass Flow Controller
Bypass flow controllers for a Liebert XDP-based system
Required Number of Open
Piping Details-Shutoff/Isolation Valves
Bypass flow controller arrangement
Evacuation and Leak Check-R-134a Pumped Circuit
Insulation
Floor Supply Return Liebert
Filling the Pumped Circuit-R-134a
System refrigerant charge for the supply and return mains
Calculating Refrigerant Charge-Example
Calculating refrigerant charge-example
Worksheet to calculate refrigerant charge
Checklist for Proper Installation
Liebert iCOM Components and Functions
Escape Key Down Arrow Key
Display Lamp Indicators
Keyboard icons and functions
Icon Key Name Function
Accessing Menus and Settings Viewing Data
Navigating Through the Liebert iCOM Display
Unit Sensor a Sensor B Pump Operation Roo m Data Room Data
Cooling Module Overview
ACK High Chilled Water Temp
Entering the Password
Entering the password
Changing Liebert iCOM’s Display Settings
Changing Operational Settings
Highlight the setting to be changed by pressing Enter
English US
Graphical Data Record
Liebert iCOM User Menu Icons and Legend
Liebert XDP User Menu screen
Liebert iCOM User Menu Screens
Spare Parts
Event Log
SET Alarms page 1
Sensor Data screen, page 1
Sensor Data screen, page 2
U401 U402
Online
XDV8SK
XDH32SK
XDO20SK 20 KW
Liebert iCOM Service Menu Icons and Legend
Setpoints Maintenance Diagnostics Set Alarms
Service Mode
Settings
Liebert iCOM Service Menu Screens
Liebert XDP Service Menu screen
Liebert iCOM Control-Firmware Version XP1.00.010.STD
Maintenance-Basic Settings screen, page 1
Maintenance-Pump 1 Settings screen, page 2
Maintenance-Pump 2 Settings screen, page 3
Diagnostics/Service Mode screen, page 1
Manual Mode Control Type-Not currently used
Diagnostics/Service Mode screen, page 5
Set Alarms screen, page 1
Set Alarms screen, page 2
Delay EN-DIS Type
High Temp Sensor a Enable ALM
LOW Temp Sensor a Enable ALM
High Temp Sensor B Enable ALM
High Refrigerant Temp Enable ALM
LOW Refrigerant Temp Enable ALM
Supply Refrigerant Sensor Enable ALM
Loss of Flow Pump Enable ALM
Condensation Detected Enable ALM
FAN Failure Enable ALM
Customer Input Enable ALM
Smoke Detected Enable ALM
S601
S612
S801
MAC
GBP
System/Network Setup screen-Unit, page 1
Unit
S834 S835
S401
Node ID Delay EN-DIS Type
Condensation Detected Enable
Local Module Shutdown Enable ALM
Sensor Failure Enable ALM
Node ID Delay EN-DIS Type
Checklist for Liebert XDP Startup
Liebert XDP pump light indicator-208V and 400V units
Indicator Lights Description Green Red
Starting the Liebert XDP with Liebert iCOM Controller
System R-134a liquid level at 160kW load
Alarm Descriptions
Alarm Descriptions and Solutions
System Shutdown Causes
Unit Is Off By Refrig Sens Fail
Unit Is Off By High CW Temp
Unit Is Off By Pump Short Cycle
Troubleshooting the Liebert XDP
Symptom Possible Cause Check or Remedy
See Clogged Filter Dryer and/or Impeller symptom
Maintenance
Fluorinated Greenhouse Gas Requirements
Liebert XDP160 specifications