Liebert XDP160RM, XDP160RC, XDP160RA user manual DIP Switch and Jumper Settings for Remote Sensors

Page 21

Installation

2.2.3DIP Switch and Jumper Settings for Remote Sensors

The Liebert XDP is shipped with jumpers and DIP switch settings for normal operation. See Figure 15.

Figure 15 DIP switch and jumper settings

 

MICROPROCESSOR AND I/O BOARD

DIP

 

1

OFF ON

 

 

Switches

 

 

 

 

 

2

 

 

 

OFF ON

 

3

 

 

 

2

1

 

4

 

 

 

 

5

 

 

 

5

3

 

6

 

 

 

6

4

 

7

 

 

 

 

8

 

 

 

7

9

SW2

9

 

 

 

8

10

10

Jumpers

 

 

 

Jumper

 

on 1-2, 5-6

1

 

P68

 

 

on 1-2

 

 

 

2

 

 

 

P78

 

2

4

6

3

 

 

 

 

 

 

1

3

5

REMOTE T/HSENSOR “A”

DIP

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switches

 

 

 

 

 

 

 

 

 

 

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

2

1

SW1

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

3

5

 

 

 

 

 

 

 

 

 

 

 

 

4

 

P3

 

 

 

 

 

 

 

Jumper

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on 2-3

 

 

 

3

2

 

1

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 16 Unit-to-unit networking connections

 

UNIT DISPLAY

 

1

Jumper on 1-2

2

P78

 

 

DIP

 

Switches

3

 

 

 

 

OFF ON

 

 

 

 

OFF ON

 

1

None

1

SW3

2

 

 

3

 

2

 

 

 

3

 

 

4

 

4

 

 

5

 

5

 

 

 

6

 

 

6

 

7

 

 

7

 

8

 

 

 

 

 

 

8

 

REMOTE T/H SENSOR “B”

ON

 

 

 

 

 

 

 

 

 

 

DIP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switches

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

1

2

SW1 1

2

3

 

4

5

6

7

8

 

3

5

 

 

 

 

 

 

 

 

 

 

 

 

P3

 

 

 

 

 

 

Jumper

4

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

on 2-3

 

3

2

1

 

302211

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Rev. 2

CAN Cable

 

 

 

Red Crossover

 

 

 

 

 

Ethernet Cable

Termination

 

 

 

 

 

 

 

 

 

Crossover

 

Plug

 

 

 

 

P64 P66P67

 

 

 

 

Coupler

 

 

 

 

 

 

See Note 1

 

 

 

 

 

 

 

 

 

 

 

Customer

 

 

 

 

 

 

Connection

 

 

 

 

 

 

Points

 

 

 

1. Both cables (P64 and P66) are required.

 

 

 

 

 

 

Unit Display (Rear View)

 

 

 

 

 

 

2. A crossover coupler is provided for unit-to-unit (U2U)

 

 

 

 

 

 

 

networking. Unplug the red cable from P64 on the

 

 

 

 

 

 

 

microprocessor and I/O board and connect to one side

 

E5

P67

P11

P13

P7

 

of the crossover coupler. The first customer connection

 

 

P12

 

 

 

point is to P64 on the microprocessor and I/O board.

 

 

 

 

 

 

 

 

 

P66

 

 

 

 

 

 

 

 

U2U Networking Switch

The second customer connection point is to the other

 

 

 

P64

 

 

side of the crossover coupler. This connects the

 

 

 

 

 

(Field Supplied)

 

 

 

 

 

 

microprocessor and I/O board and display to the

Not

P63

 

Liebert iCOM

 

 

 

 

 

private U2U network.

Used

 

 

Microprocessor

 

 

P61

 

 

 

 

 

P65

& I/O Board

 

 

 

 

 

 

 

 

To / From Other

 

 

 

 

 

Networked Units

 

 

 

 

 

 

 

 

 

 

 

 

Straight Through

302211

 

 

 

 

 

 

Ethernet Cables

Rev. 2

15

Image 21
Contents Liebert XDP with Liebert iCOM Control Page Table of Contents Alarm Descriptions and Solutions SpecificationsStart the Liebert XDP with Liebert Icom Figures Tables Important Safety Instructions Example XDP160RA Pumping Unit Redundancy Place holder Revision Level Liebert= 460V-3ph-60Hz Place holder Equipment Inspection General Product InformationProduct/System Description Minimum LoadHandling the Liebert XDP While it is on Skid and Packaged Equipment HandlingUnpacking the Liebert XDP Removing the Unit from the Skid Using a ForkliftUse a forklift to remove the Liebert XDP from the skid Removing the Unit from the Skid using RiggingSpreader Bars Bracket Moving the Liebert XDP Using Piano JacksSecuring the Liebert XDP to piano jacks Removing the Unit from the Piano JacksLiebert XDP dimensions Mechanical ConsiderationsPositioning the Liebert XDP Electrical Considerations Unit piping outlet connection sizes, inches, OD CuModel Pipe Connection Point 50/60 Hz Front view of Liebert XDP and electrical enclosure Connecting High-Voltage CablesHigh voltage connections-60Hz High voltage connections-50Hz Extra Low Voltage ELV ConnectionsConnecting the remote temperature/humidity sensors DIP switch and jumper settings DIP Switch and Jumper Settings for Remote SensorsLiebert XDP extra low voltage field connections points Field Connections-Optional for All UnitsSuggested remote sensor placement Remote Sensor Installation-Proper PlacementConnection Sizes European Union Fluorinated Greenhouse Gas RequirementsRecommended Pipe Size Supply, return pipe sizes for refrigerant loopPiping Installation-R-134a Pumped Circuit Piping Installation MethodsLiebert XDP Interconnection with Liebert XD Cooling Modules Liebert XDPBypass Flow Controller Piping MainsBypass flow controllers for a Liebert XDP-based system Required Number of OpenBypass flow controller arrangement Piping Details-Shutoff/Isolation ValvesEvacuation and Leak Check-R-134a Pumped Circuit InsulationFloor Supply Return Liebert System refrigerant charge for the supply and return mains Filling the Pumped Circuit-R-134aCalculating Refrigerant Charge-Example Calculating refrigerant charge-exampleWorksheet to calculate refrigerant charge Checklist for Proper Installation Escape Key Down Arrow Key Liebert iCOM Components and FunctionsDisplay Lamp Indicators Keyboard icons and functionsIcon Key Name Function Accessing Menus and Settings Viewing Data Navigating Through the Liebert iCOM DisplayUnit Sensor a Sensor B Pump Operation Roo m Data Room Data ACK High Chilled Water Temp Cooling Module OverviewEntering the password Entering the PasswordChanging Operational Settings Changing Liebert iCOM’s Display SettingsHighlight the setting to be changed by pressing Enter English USLiebert iCOM User Menu Icons and Legend Graphical Data RecordLiebert XDP User Menu screen Liebert iCOM User Menu Screens Spare PartsEvent Log SET Alarms page 1 Sensor Data screen, page 1 Sensor Data screen, page 2 U401 U402 XDV8SK OnlineXDO20SK 20 KW XDH32SKSetpoints Maintenance Diagnostics Set Alarms Liebert iCOM Service Menu Icons and LegendService Mode SettingsLiebert XDP Service Menu screen Liebert iCOM Service Menu ScreensLiebert iCOM Control-Firmware Version XP1.00.010.STD Maintenance-Basic Settings screen, page 1 Maintenance-Pump 1 Settings screen, page 2 Maintenance-Pump 2 Settings screen, page 3 Diagnostics/Service Mode screen, page 1 Manual Mode Control Type-Not currently used Diagnostics/Service Mode screen, page 5 Set Alarms screen, page 1 Set Alarms screen, page 2 High Temp Sensor a Enable ALM Delay EN-DIS TypeLOW Temp Sensor a Enable ALM High Temp Sensor B Enable ALMLOW Refrigerant Temp Enable ALM High Refrigerant Temp Enable ALMSupply Refrigerant Sensor Enable ALM Loss of Flow Pump Enable ALMFAN Failure Enable ALM Condensation Detected Enable ALMCustomer Input Enable ALM Smoke Detected Enable ALMS601 S612 S801 GBP MACUnit System/Network Setup screen-Unit, page 1S834 S835 S401 Condensation Detected Enable Node ID Delay EN-DIS TypeLocal Module Shutdown Enable ALM Sensor Failure Enable ALMNode ID Delay EN-DIS Type Checklist for Liebert XDP Startup Liebert XDP pump light indicator-208V and 400V unitsIndicator Lights Description Green Red System R-134a liquid level at 160kW load Starting the Liebert XDP with Liebert iCOM ControllerAlarm Descriptions Alarm Descriptions and Solutions Unit Is Off By Refrig Sens Fail System Shutdown CausesUnit Is Off By High CW Temp Unit Is Off By Pump Short CycleSymptom Possible Cause Check or Remedy Troubleshooting the Liebert XDPSee Clogged Filter Dryer and/or Impeller symptom Fluorinated Greenhouse Gas Requirements MaintenanceLiebert XDP160 specifications 2006/42/EC 2004/108/EC 2006/95/EC 97/23/EC Liebert Corporation Dearborn Drive Box Columbus, OHIs t Ne tTwor k Care

XDP160RA, XDP160RC, XDP160RM specifications

The Liebert XDP series is an innovative line of uninterruptible power supplies (UPS) designed to safeguard critical IT equipment and ensure reliability in demanding environments. The XDP160RM, XDP160RC, and XDP160RA models are distinguished by their robust features and advanced technologies, making them ideal for data centers, server rooms, and telecommunications.

One of the standout features of the Liebert XDP series is its high power density. The XDP160RM, XDP160RC, and XDP160RA models provide 160 kVA of power in a compact design, occupying minimal floor space. This efficient design maximizes data center performance without compromising on reliability.

All three models utilize advanced digital signal processing (DSP) technology that enhances system performance and efficiency. The DSP technology ensures high efficiency rates, often exceeding 95% in online mode. This not only reduces energy costs but also minimizes heat output, contributing to a more sustainable operational environment.

The Liebert XDP series is equipped with multiple output configurations, allowing for versatile installation options. The modular architecture of the UPS systems allows for easy scalability to meet future power demands without the need for complete system replacement. This flexibility is crucial for businesses expecting growth or changes in IT infrastructure.

Another important aspect of the XDP160RM, XDP160RC, and XDP160RA is their advanced battery management systems, which optimize battery performance and longevity. The integrated smart battery charging technology prevents overcharging and extends battery life, ensuring that the UPS is always ready during power interruptions.

Additionally, the systems are designed with user-friendly interfaces that facilitate ease of monitoring and management. With real-time data on power usage, battery status, and overall system health, IT administrators can quickly address any issues that arise. The monitoring capabilities extend to remote access, enabling users to manage the UPS systems from virtually anywhere.

The Liebert XDP series also incorporates enhanced safety features, including fault detection and automated alerts, which further bolster reliability. With a strong commitment to maintaining uptime and safeguarding critical operations, the XDP models are a wise investment for any organization reliant on continuous power availability.

In conclusion, the Liebert XDP160RM, XDP160RC, and XDP160RA UPS systems are engineered to deliver exceptional power protection through high efficiency, advanced technologies, and user-friendly management features. These models are positioned to meet the rigorous demands of modern IT environments, ensuring that businesses can maintain operations without interruption.