Placement of Unit

Slide the unit from the outside wall into your wine cellar with the outer flange flush to the outside wall. Secure the flange to the wall through the predrilled holes. The screws should penetrate the studs as well as the upper and lower supports to provide adequate support for the WhisperKOOL System (see illustration). Seal all cracks and gaps around the WhisperKOOL unit with caulking to prevent air leakage.

(If you use molding, it should be attached to the walls, never to the WhisperKOOL unit itself.)

Electrical Outlet

The unit is equipped with two electrical outlets, one for installation inside the cellar and the other for installation outside the cellar. Both outlets are initially covered and secured with screws. Select the out- let to be used and remove that cover; the unused outlet must remain covered to avoid live electrical charge. Remove side electrical outlet cover for easy through the wall installation. Immediately replace cover when install is completed and prior to powering up unit if electrical cord is not attached to outlet.

Two-by-Four Upper Support

Wall Stud

Wall Stud

2” x 4”

Lower Support

Drain line

Electrical Outlets

Slide unit, outside-in, into your cellar, and secure all screws firmly to the studs and supports.

Installing Thermostat

Attach the thermostat to the front of the unit using the mounting bracket. Make sure the black male plastic plug from the unit is securely fitted into the female plug located on the circuit board of the thermostat. To complete the installation, insert the small black screws into each side of the thermostat PDT/PDT Jr. securing it to the mounting bracket. Insert the probe into a wine bottle 3/4 full of water.

Attach the PDT mounting bracket.

Attach the PDT to the mounting bracket.

Page 12

XLT 020111

Image 14
Contents XLT Page Table of Contents Owners Please NoteHow does the WhisperKOOL System Work? What is the WhisperKOOL System?Introduction Receiving & Inspecting the Unit Customer Warranty RegistrationContents Receiving and Inspecting the UnitQuick Start Guide Preparing the Wine Cellar Wall & Ceiling FramingDoor Unobstructed AirflowMounting the Unit Ambient Temperature Factor VentilationCut horizontal lines from stud to stud Tools NeededMark the horizontal lines with a level Cut vertical lines along the inside edge of the studs Frame the hole with two-by-four supportsElectrical Outlet InstallationElectrical Needs Sizing Unit to RoomLiquid Measuring Thermostat System Testing UnitApplying Insulation Tape Attach precut foam tape to the unit’s flangeInstalling Thermostat Placement of UnitCondensate Evaporator Switch Using the Whisperkool SystemPower Switch Location of control switchesLiquid Measuring Thermostat System To Use the thermostatOperation PDT JR Operating InstructionsButtons PDT Operating Instructions PDTNormal Operation Maintenance ScheduleMaintenance Humidity Control85F Max Using the Thermostat ControllerDucting Try this first Troubleshooting GuideAirflow Cool air drops and exits beneath door Door SealAir flows on both sides of the wall Mount WhisperKOOL high in the room Unit MountingThermostat Icing Up Power RequirementsCondensation DrainlineRepairing Units Removing Rivets Consumer Care ProgramTroubleshooting Checklist General InspectionSpecific Performance Issues Unit is Not Cooling Sufficiently or Not Cooling at AllTemperature Differential Testing Do not Exceed 24HRS on Bypass PlugInlet AIR -- Evaporator Front Side Temperature / Test timeEvaporator Front Side Condenser Back Side Inlet AIR -- Condenser Back SideConclusions Accessories for Cooling Units Technical AssistanceInstallation Terms and Conditions Five 5 Year Compressor Limited WarrantyProduct Warranty Limitations and Exclusions Product Installation RequirementsMaintenance Requirements ModelXLTSerial NumberA Questions or Additional InformationWhisperKOOL WhisperKOOL