Repairing Units - Removing Rivets

Only a certified HVAC tech should work on the units. We do not want owners opening the units for their own safety.

1.Unplug the WhisperKOOL unit.

2.Remove the WhisperKOOL unit from the wall mounting and set it on a sturdy workbench.

3.Drill out the rivets on the top panel that hold the case together, using a 5/32 (size) drill bit. This will destroy the rivets.

4.Remove the top off of unit, and carefully remove the insulation (if any) from the top.

5.When replacing the panel, you can use rivets or small metal 6-32 3/8” Phillips Pan Head Screws. It is recommended to locate any necessary parts at your local hardware store prior to the service.

Consumer Care Program

The Consumer Care Program is designed to expedite the shipment of a replacement unit to your location quickly in order to get your cellar cooling again.

This program involves contacting our Customer Service department to purchase a replacement unit as the quickest solution. The unit is tested in our controlled environment and is ready for immediate use.

Complete details of our program including pricing are available by contacting our Customer Service department.

Page 23

XLT 020111

Image 25
Contents XLT Page Owners Please Note Table of ContentsIntroduction What is the WhisperKOOL System?How does the WhisperKOOL System Work? Contents Customer Warranty RegistrationReceiving & Inspecting the Unit Receiving and Inspecting the UnitQuick Start Guide Wall & Ceiling Framing Preparing the Wine CellarMounting the Unit Unobstructed AirflowDoor Ventilation Ambient Temperature FactorMark the horizontal lines with a level Tools NeededCut horizontal lines from stud to stud Frame the hole with two-by-four supports Cut vertical lines along the inside edge of the studsElectrical Needs InstallationElectrical Outlet Sizing Unit to RoomApplying Insulation Tape Testing UnitLiquid Measuring Thermostat System Attach precut foam tape to the unit’s flangePlacement of Unit Installing ThermostatPower Switch Using the Whisperkool SystemCondensate Evaporator Switch Location of control switchesTo Use the thermostat Liquid Measuring Thermostat SystemButtons PDT JR Operating InstructionsOperation PDT PDT Operating InstructionsMaintenance Maintenance ScheduleNormal Operation Humidity ControlDucting Using the Thermostat Controller85F Max Airflow Troubleshooting GuideTry this first Air flows on both sides of the wall Door SealCool air drops and exits beneath door Thermostat Unit MountingMount WhisperKOOL high in the room Condensation Power RequirementsIcing Up DrainlineConsumer Care Program Repairing Units Removing RivetsGeneral Inspection Troubleshooting ChecklistUnit is Not Cooling Sufficiently or Not Cooling at All Specific Performance IssuesDo not Exceed 24HRS on Bypass Plug Temperature Differential TestingEvaporator Front Side Condenser Back Side Temperature / Test timeInlet AIR -- Evaporator Front Side Inlet AIR -- Condenser Back SideConclusions Technical Assistance Accessories for Cooling UnitsFive 5 Year Compressor Limited Warranty Installation Terms and ConditionsProduct Installation Requirements Product Warranty Limitations and ExclusionsMaintenance Requirements WhisperKOOL Questions or Additional InformationModelXLTSerial NumberA WhisperKOOL