INTRODUCTION

Thank you for purchasing theWhisperKOOL® wine cellar temperature and humidity maintenance system.

Please take the time to read through the owner's manual so you understand the correct operations of the WhisperKOOL unit.

What is the WhisperKOOL System?

The WhisperKOOL system is a specialized piece of equipment designed to absorb heat from a cellar and discharge it through the rear of the unit into an adjacent room. The unit will operate 75 to 80 percent of the time in order to maintain an ideal temperature and humidity in a wine cellar. Essentially, it will operate as needed to absorb the heat that naturally permeates into the cellar. It is important to follow the cellar construction guidelines provided on page 5 in order to maximize effectiveness based on the quality of efficiency in the vapor barrier, therefore reduce the operating time of the cooling unit itself.

How does the WhisperKOOL System Work?

The WhisperKOOL system is designed to maintain humidity, while measuring and maintaining the wine temperature in the cellar. This is achieved by gently cooling rather than by quick-chilling.

Temperature Setting: The WhisperKOOL unit can be set at any temperature within the acceptable wine-aging range of 50°F -to- 70°F. It is designed to cool 30°F cooler than the ambient temperature of the space it is exhausting to with proper ventilation.

Humidity Control: There are no separate controls for maintaining proper humidity. Humidity is managed through the design and engineering of the unit. For more information about this process, see Normal Operation on page 17.

All units come with a drain line for additional removal of excess condensate, as a back up system to the Condensate Evaporator which is used to dissipate excess condensations. It is mandatory to install the drain line attachment for the unit to function effectively, preventing overflows and leaks from build up of condensate. Failure to install the drain line voids warranty.

The WhisperKOOL system is designed to be mounted through an interior wall into the cellar. The unit will operate correctly in a controlled environment to properly manage the effective cooling of the cellar. The unit is not designed to withstand the elements of an outdoor climate where summer temperatures exceed 85 degrees or in winter environments where temperatures reach below 55°F. The components are not designed for these extreme conditions and premature failure may occur.

Note: Improperly preparing your enclosure or incorrectly installing your WhisperKOOL system may cause unit failure, leaking of condensation, and other negative side effects.

Page 2

XLT 020111

Image 4
Contents XLT Page Table of Contents Owners Please NoteIntroduction What is the WhisperKOOL System?How does the WhisperKOOL System Work? Customer Warranty Registration ContentsReceiving & Inspecting the Unit Receiving and Inspecting the UnitQuick Start Guide Preparing the Wine Cellar Wall & Ceiling FramingMounting the Unit Unobstructed AirflowDoor Ambient Temperature Factor VentilationMark the horizontal lines with a level Tools NeededCut horizontal lines from stud to stud Cut vertical lines along the inside edge of the studs Frame the hole with two-by-four supportsInstallation Electrical NeedsElectrical Outlet Sizing Unit to RoomTesting Unit Applying Insulation TapeLiquid Measuring Thermostat System Attach precut foam tape to the unit’s flangeInstalling Thermostat Placement of UnitUsing the Whisperkool System Power SwitchCondensate Evaporator Switch Location of control switchesLiquid Measuring Thermostat System To Use the thermostatButtons PDT JR Operating InstructionsOperation PDT Operating Instructions PDTMaintenance Schedule MaintenanceNormal Operation Humidity ControlDucting Using the Thermostat Controller85F Max Airflow Troubleshooting GuideTry this first Air flows on both sides of the wall Door SealCool air drops and exits beneath door Thermostat Unit MountingMount WhisperKOOL high in the room Power Requirements CondensationIcing Up DrainlineRepairing Units Removing Rivets Consumer Care ProgramTroubleshooting Checklist General InspectionSpecific Performance Issues Unit is Not Cooling Sufficiently or Not Cooling at AllTemperature Differential Testing Do not Exceed 24HRS on Bypass PlugTemperature / Test time Evaporator Front Side Condenser Back SideInlet AIR -- Evaporator Front Side Inlet AIR -- Condenser Back SideConclusions Accessories for Cooling Units Technical AssistanceInstallation Terms and Conditions Five 5 Year Compressor Limited WarrantyProduct Warranty Limitations and Exclusions Product Installation RequirementsMaintenance Requirements WhisperKOOL Questions or Additional InformationModelXLTSerial NumberA WhisperKOOL