WhisperKool XLT 4200, XLT 8000, XLT 3000 PDT JR Operating Instructions, Buttons, Operation

Page 17

PDT JR OPERATING INSTRUCTIONS

Operating Instructions for WhisperKOOL PDT JR. Thermostat

Indicators

There are three colored lights on the left side of the thermostat:

PWR (Green) – When this light is on, the unit is powered.

RUN (Yellow) – When this light is on, the compressor is running. If the light is flashing, the unit is currently in the five-minute lockout.

SET (Red) – This light flashes when the set-point temperature is changed by pressing one of the three control buttons (see below). It flashes once for each press of the () or () button, and twice when the 55 button is pressed.

When the unit is first turned on, all three lights flash slowly while the thermostat starts up. Once the unit completes its start-up check, the compressor is locked out for five minutes. During this time the RUN light will be flashing slowly (1 flash per second).

All three lights will flash rapidly if there is no probe connected to the thermostat.

Buttons

To change the set-point temperature, press either the (), (), OR (55) buttons. The SET light will flash once for each 1°F the set-point is changed. This set-point will remain in memory until you change it.

If you forget where the unit is set, pressing the (55) button will reset the set-point to 55°F and the SET light will flash twice. The temperature cannot be adjusted below 50°F or above 76°F. Attempting to set the unit outside this range will cause the SET light to rapidly flash.

Operation

Whenever the compressor shuts off normally, a five-minute lockout period begins and the RUN light will be flashing slowly (1 flash per second).

If the compressor runs for 90 continuous minutes, a five-minute defrost cycle is forced, during which time the compressor will not run. During this defrost cycle the RUN light will be flashing rapidly (2.5 flashes per second).

Page 15

XLT 020111

Image 17
Contents XLT Page Owners Please Note Table of ContentsHow does the WhisperKOOL System Work? What is the WhisperKOOL System?Introduction Contents Customer Warranty RegistrationReceiving & Inspecting the Unit Receiving and Inspecting the UnitQuick Start Guide Wall & Ceiling Framing Preparing the Wine CellarDoor Unobstructed AirflowMounting the Unit Ventilation Ambient Temperature FactorCut horizontal lines from stud to stud Tools NeededMark the horizontal lines with a level Frame the hole with two-by-four supports Cut vertical lines along the inside edge of the studsElectrical Needs InstallationElectrical Outlet Sizing Unit to RoomApplying Insulation Tape Testing UnitLiquid Measuring Thermostat System Attach precut foam tape to the unit’s flangePlacement of Unit Installing ThermostatPower Switch Using the Whisperkool SystemCondensate Evaporator Switch Location of control switchesTo Use the thermostat Liquid Measuring Thermostat SystemOperation PDT JR Operating InstructionsButtons PDT PDT Operating InstructionsMaintenance Maintenance ScheduleNormal Operation Humidity Control85F Max Using the Thermostat ControllerDucting Try this first Troubleshooting GuideAirflow Cool air drops and exits beneath door Door SealAir flows on both sides of the wall Mount WhisperKOOL high in the room Unit MountingThermostat Condensation Power RequirementsIcing Up DrainlineConsumer Care Program Repairing Units Removing RivetsGeneral Inspection Troubleshooting ChecklistUnit is Not Cooling Sufficiently or Not Cooling at All Specific Performance IssuesDo not Exceed 24HRS on Bypass Plug Temperature Differential TestingEvaporator Front Side Condenser Back Side Temperature / Test timeInlet AIR -- Evaporator Front Side Inlet AIR -- Condenser Back SideConclusions Technical Assistance Accessories for Cooling UnitsFive 5 Year Compressor Limited Warranty Installation Terms and ConditionsProduct Installation Requirements Product Warranty Limitations and ExclusionsMaintenance Requirements ModelXLTSerial NumberA Questions or Additional InformationWhisperKOOL WhisperKOOL