WhisperKool XLT 4200 Installation, Electrical Needs, Electrical Outlet, Sizing Unit to Room

Page 12

INSTALLATION

Electrical Needs

The WhisperKOOL System requires a dedicated 110-volt 20-amp circuit. The unit draws a large amount of amps at initial start up. By designating a dedicated circuit breaker, you will guarantee the unit has enough power to run effectively. Contact your electrician for installation of this dedicated electrical circuit.

Electrical Outlet

The unit is equipped with two electrical outlets, one for installation inside the cellar and the other for installation outside the cellar. The outlet on the inside is covered and has been secured with screws. Regardless of which side is utilized, the other outlet must then be covered in order to avoid a live elec- trical charge.

XLT units, built after June 2007, come equipped with a 3-position ON/OFF power switch. The upper po- sition activates power from the cellar side outlet located on the side of unit. The bottom position activates power from the rear position outlet. The center position is OFF and is simply used when the owner does not need to utilize the equipment.

Purchase a surge protector or power conditioner to plug your WhisperKOOL unit into. As with any sen- sitive electrical equipment, the WhisperKOOL unit’s circuitry may be damaged by power surges and spikes. Power surges and spikes are not covered by the WhisperKOOL warranty.

Do not use a Ground Fault Interrupter (GFI) with this product. The cooling unit will draw more amperage than the GFI will allow.

Upon plugging the unit in and turning it on, there will be a five minute delay before the unit starts. This is based on the function of the thermostat.

Sizing Unit to Room

The specification chart will provide information on the unit’s room size cooling capacity. There are cir- cumstances in which a cellar design may require a larger unit due to some existing design restrictions. In such a case, we recommend that the customer consider purchasing a unit with a larger capacity to compensate for the design limitations. Issues such as glass doors, concrete walls and floors may seem adequate but do not offer the insulation capacity required to maintain the optimum environment.

MODEL

AMPS

AMPS

PRODUCT DIMENSIONS

ROOM SIZE

 

 

 

 

 

 

(starting)

(running)

(H x W x D)

(cubic feet)

 

 

 

 

 

WK 1600

28.32

4.5

15.75" x 14.25" x 17"

300

WK 3000

30.00

6

15.75" x 14.25" x 17"

650

WK 4200

32.00

9

15.75" x 14.25" x 17"

1000

WK 6000

36.00

9.5

22.5" x 14.25" x 21.25"

1500

WK 8000

36.00

10

22.5" x 14.25" x 21.25"

2000

Page 10

XLT 020111

Image 12
Contents XLT Page Table of Contents Owners Please NoteWhat is the WhisperKOOL System? IntroductionHow does the WhisperKOOL System Work? Customer Warranty Registration ContentsReceiving & Inspecting the Unit Receiving and Inspecting the UnitQuick Start Guide Preparing the Wine Cellar Wall & Ceiling FramingUnobstructed Airflow Mounting the UnitDoor Ambient Temperature Factor VentilationTools Needed Mark the horizontal lines with a levelCut horizontal lines from stud to stud Cut vertical lines along the inside edge of the studs Frame the hole with two-by-four supportsInstallation Electrical NeedsElectrical Outlet Sizing Unit to RoomTesting Unit Applying Insulation TapeLiquid Measuring Thermostat System Attach precut foam tape to the unit’s flangeInstalling Thermostat Placement of UnitUsing the Whisperkool System Power SwitchCondensate Evaporator Switch Location of control switchesLiquid Measuring Thermostat System To Use the thermostatPDT JR Operating Instructions ButtonsOperation PDT Operating Instructions PDTMaintenance Schedule MaintenanceNormal Operation Humidity ControlUsing the Thermostat Controller Ducting85F Max Troubleshooting Guide AirflowTry this first Door Seal Air flows on both sides of the wallCool air drops and exits beneath door Unit Mounting ThermostatMount WhisperKOOL high in the room Power Requirements CondensationIcing Up DrainlineRepairing Units Removing Rivets Consumer Care ProgramTroubleshooting Checklist General InspectionSpecific Performance Issues Unit is Not Cooling Sufficiently or Not Cooling at AllTemperature Differential Testing Do not Exceed 24HRS on Bypass PlugTemperature / Test time Evaporator Front Side Condenser Back SideInlet AIR -- Evaporator Front Side Inlet AIR -- Condenser Back SideConclusions Accessories for Cooling Units Technical AssistanceInstallation Terms and Conditions Five 5 Year Compressor Limited WarrantyProduct Warranty Limitations and Exclusions Product Installation RequirementsMaintenance Requirements Questions or Additional Information WhisperKOOLModelXLTSerial NumberA WhisperKOOL