WhisperKool Comprehensive Guide for Wine Cooling Systems XLT Series

Page 19

NORMAL OPERATION

WhisperKOOL systems are designed to maintain both temperature and humidity. Once the system is installed and the temperature set, it will run continuously until the wine cellar is at your set wine temperature. This may be as long as three weeks, depending on the size of the room, the quality (R-value) of insulation, the original temperature of the wine, and the number of bottles residing in the cellar. Once the cellar has achieved the set temperature, the WhisperKOOL unit will cycle to maintain ±1°F of your set temperature.

Note: Defrost Cycle will turn off the unit for 5 minutes every 90 minutes to allow any accumulated frost to dissolve.

The WhisperKOOL system will run more often than a refrigerator or air conditioner, due to its gentle cooling and humidity maintenance.

People often make the mistake of comparing the performance of refrigerators with the performance and cycling of wine storage equipment. Wine cellar cooling systems are highly specialized and designed for one purpose­­only–long term storage of wine.

Maintenance

The following maintenance should be performed on your WhisperKOOL unit at least once every six months to promote longevity and optimal performance.

Vacuum the WhisperKOOL unit to clean the evaporator and condenser coils to prevent air blockage. The condenser coils reside behind the grill on the back of the WhisperKOOL unit. Don’t try to open the unit yourself. Just vacuum the surface of the grill and remove any lint or dust that has accumulated.

Humidity Control

There are no separate switches in order to maintain humidity. The cooling unit is designed to maintain relative humidity at 50-70%.

The WhisperKOOL units do not create humidity. If you live in a dry area of the country you many need to create humidity in the wine cellar. This can be done by introducing a non-heat humidifier, or installing a small fountain within the cellar.

MAINTENANCE SCHEDULE

It is the user’s responsibility to remove any accumulated dust, lint, or other debris from the front and rear intake grilles. This will restrict the airflow and may affect the unit’s ability to function properly. Periodically cleaning the unit’s vents will help assure maximum cooling efficiency. The drain tube must also be checked and kept clean and free of debris and mold to maintain proper performance.

Monthly

1. Check for unusual noise or vibration

 

2.

Check the drainline to see if it is above the waterline if draining into a vessel.

 

 

 

Quarterly

1.

Clean front and rear intake grilles.

 

 

Annually

1. Use a vacuum with brush attachment to clean grilles.

 

2.

Inspect for corrosion.

 

3. Check wiring connections and integrity of cords.

 

4. Pour a 50/50 bleach solution into the drainline every spring.

 

 

 

Page 17

XLT 020111

Image 19
Contents XLT Page Owners Please Note Table of ContentsIntroduction What is the WhisperKOOL System?How does the WhisperKOOL System Work? Receiving and Inspecting the Unit Customer Warranty RegistrationContents Receiving & Inspecting the UnitQuick Start Guide Wall & Ceiling Framing Preparing the Wine CellarMounting the Unit Unobstructed AirflowDoor Ventilation Ambient Temperature FactorMark the horizontal lines with a level Tools NeededCut horizontal lines from stud to stud Frame the hole with two-by-four supports Cut vertical lines along the inside edge of the studsSizing Unit to Room InstallationElectrical Needs Electrical OutletAttach precut foam tape to the unit’s flange Testing UnitApplying Insulation Tape Liquid Measuring Thermostat SystemPlacement of Unit Installing ThermostatLocation of control switches Using the Whisperkool SystemPower Switch Condensate Evaporator SwitchTo Use the thermostat Liquid Measuring Thermostat SystemButtons PDT JR Operating InstructionsOperation PDT PDT Operating InstructionsHumidity Control Maintenance ScheduleMaintenance Normal OperationDucting Using the Thermostat Controller85F Max Airflow Troubleshooting GuideTry this first Air flows on both sides of the wall Door SealCool air drops and exits beneath door Thermostat Unit MountingMount WhisperKOOL high in the room Drainline Power RequirementsCondensation Icing UpConsumer Care Program Repairing Units Removing RivetsGeneral Inspection Troubleshooting ChecklistUnit is Not Cooling Sufficiently or Not Cooling at All Specific Performance IssuesDo not Exceed 24HRS on Bypass Plug Temperature Differential TestingInlet AIR -- Condenser Back Side Temperature / Test timeEvaporator Front Side Condenser Back Side Inlet AIR -- Evaporator Front SideConclusions Technical Assistance Accessories for Cooling UnitsFive 5 Year Compressor Limited Warranty Installation Terms and ConditionsProduct Installation Requirements Product Warranty Limitations and ExclusionsMaintenance Requirements WhisperKOOL Questions or Additional InformationModelXLTSerial NumberA WhisperKOOL